Radiative mean lives of some electronic states in beam-foil excited atomic and ionic carbon
Radiative mean lives and transition probabilities of electronic states in beam foil excited atomic and ionic carbon
Engineering topics
Publications and source records attributed to Chupp, E. L..
Radiative mean lives and transition probabilities of electronic states in beam foil excited atomic and ionic carbon
OGO-F neutron monitor for measuring cosmic ray neutron flux near earth, locating sensor on boom to minimize spacecraft produced neutrons
Solar neutron flux measurement at earth in energy region 20-120 Mev by detector in balloon flight
Onboard calibration system for gamma ray spectrometers and X ray detector in earth satellites, describing fabrication and test results for radioactive sources
An inexpensive and simple data acquisition system has been developed for balloon borne experiments and has been tested with a gamma ray detector in a balloon flight launched from Palestine, Texas. The detector used for the test consisted of an NaI(T1) scintillation crystal encased in a 1/8 in. plastic scintillator-charged particle shield. The combination was viewed by a single photomultiplier and charged particle gating was accomplished by a conventional phoswich discriminator. The pulse height analysis of the NaI events, not associated with prompt charged particle interactions, is accomplished by converting to a time spectrum using an airborne height to time converter. A range of pulse widths from 5 microseconds to 250 microseconds corresponds to energy losses in NaI from 100 to 1000 keV. The time spectrum information, along with charged particle events and barometric pressure, is fed to a mixer which modulates a 252.4 Mc FM transmitter. The original scintillator spectrum is recovered on the ground utilizing conversion circuitry at the receiver video output and a 128 channel commercial pulse height analyzer. The charged particle events of standard time width are stored with the spectrum at a fixed channel position and are therefore represented by a sharp line riding on the lower part of the NaI energy loss spectrum. An energy loss greater than 1000 keV is presented by the maximum pulse width of the converter and stored in the last analyzer channel. Barometric pressure data is transmitted by low frequency modulation of the sme FM carrier. In flight operation, the receiver video output can be recorded on a wide band tape recorder and simultaneously analyzed by the 128 channel analyzer, or the telemetered data can be analyzed later. The flight system features high pulse resolution, essentially instantaneous time response, high data rate, and flexibility; and is of modest cost. A detailed description of the system and operating performance is discussed.
Excited atomic H state radiative mean life measurements using beam-foil excitation method
Gamma ray production in paraffin by cosmic rays
Upper limit on continuous solar emission flux of neutron-proton capture gamma rays from balloon flights, comparing day and night observations
Free excited H atom Lyman alpha radiation intensity study using beam-foil excitation method
Low latitude neutron fluxes for PCN and quiet solar period, noting solar proton production of neutrons
Energy loss spectrum in CsI at small atmospheric depths, discussing time variation of 0.5-mev gamma-ray flux
Relative population and mean lifetimes of levels in hydrogen and helium atomic beams using foil method of excitation
Directional neutron detector utilizing plastic scintillator filaments for space research
Nuclear reaction products in solar flare regions - gamma rays and neutron