SU-F-T-17: A Feasibility Study for the Transit Dosimetry with a Glass Dosimeter in Brachytherapy

Purpose: Confirming the dose delivered to a patient is important to make sure the treatment quality and safety of the radiotherapy. Measuring a transit dose of the patient during the radiotherapy could be an interesting way to confirm the patient dose. In this study, we evaluated the feasibility of the transit dosimetry with a glass dosimeter in brachytherapy. Methods: We made a phantom that inserted the glass dosimeters and placed under patient lying on a couch for cervix cancer brachytherapy. The 18 glass dosimeters were placed in the phantom arranged 6 per row. A point putting 1cm vertically from the source was prescribed as 500.00 cGy. Solid phantoms of 0, 2, 4, 6, 8, 10 cm were placed between the source and the glass dosimeter. The transit dose was measured each thickness using the glass dosimeters and compared with a treatment planning system (TPS). Results: When the transit dose was smaller than 10 cGy, the average of the differences between measured values and calculated values by TPS was 0.50 cGy and the standard deviation was 0.69 cGy. If the transit dose was smaller than 100 cGy, the average of the error was 1.67 ± 4.01 cGy. The error to a point near the prescription point was −14.02 cGy per 500.00 cGy of the prescription dose. Conclusion: The distances from the sources to skin of the patient generally are within 10 cm for cervix cancer cases in brachytherapy. The results of this preliminary study showed the probability of the glass dosimeter as the transit dosimeter in brachytherapy.

60 APPLIED LIFE SCIENCES↗

SU-F-T-244: Radiotherapy Risk Estimation Based On Expert Group Survey

Purpose: To evaluate the reliability of RPN (Risk Priority Number) decided by expert group and to provide preliminary data for adapting FMEA in Korea. Methods: 1163 Incidents reported in ROSIS for 11 years were used as a real data to be compared with, and were categorized into 146 items. The questionnaire was composed of the 146 items and respondents had to valuate ‘occurrence (O)’, ‘severity (S)’, ‘detectability (D)’ of each item on a scale from 1 to 10 according to the proposed AAPM TG-100 rating scales. 19 medical physicists from 19 different organizations in Korea had participated in the survey. Because the number of ROSIS items was not evenly spread enough to be classified into 10 grades, 1–5 scale was chosen instead of 1–10 and survey result was also fit to 5 grades to compare. Results: The average O,S,D were 1.77, 3.50, 2.13, respectively and the item which had the highest RPN(32) was ‘patient movement during treatment’ in the survey. When comparing items ranked in the top 10 of each survey(O) and ROSIS database, two items were duplicated and ‘Simulation’ and ’Treatment’ were the most frequently ranked RT process in top 10 of survey and ROSIS each. The Chronbach α of each RT process were ranged from 0.74 to 0.99 and p-value was <0.001. When comparing O*D, the average difference was 1.4. Conclusion: This work indicates the deviation between actual risk and expectation. Considering that the respondents were Korean and ROSIS is mainly composed of incidents happened in European countries and some of the top 10 items of ROSIS cannot be applied in radiotherapy procedure in Korea, the deviation could have been came from procedural difference. Moreover, if expert group was consisted of experts from various parts, expectation might have been more accurate. Therefore, further research on radiotherapy risk estimation is needed.

60 APPLIED LIFE SCIENCES↗

SU-F-T-329: Characteristic Study of a Rado-Photoluminescenct Glass Dosimeter with Accumulated Dose

Purpose: This study investigated the effect of accumulated dose on radiophotoluminescent glass dosimeter in megavoltage photon. Methods: 45 commercially-available radio-photoluminescence glass dosimeters (RPLGD; GD-302M, Asahi Techno Glass Co., Shizuoka, JAPAN) were irradiated to 10 × 10 cm{sup 2} open-field with 6, 10 and 15 MV photon beams at 100 cm of source to surface distance and dose maximum depths. Each energy has consists of five groups which is consists of three detectors. A group #1 and #2 was irradiated about 1 Gy to 100 Gy, and estimated the integral dose response with and without annealing procedure. A group #3 was read the dose after irradiated 10 Gy of dose by 10 times repeatedly to estimate the fading effect of RPLGD. A group #4 and #5 was produced same ways with different irradiation dose such as 50 Gy for group #4 and 100 Gy for group #5. Results: From the results of group #1 and #2, an annealed detector shows linear response to integral dose but other detectors without the annealing process, has supra linearity for integral dose especially close to 100 Gy dose. For group #3, #4 and #5, the dose response of repeated irradiation, the dose response was decreased about 15%, 12% and 7% for 6 MV, 10 MV and 15MV. Conclusion: It was found that RPLGD response to accumulated dose was supra linear and this respond was altered with amount of accumulated dose to the RPLGD. In addition, the fading effect need to be concern with RPLGD.

36 MATERIALS SCIENCE↗

SU-E-T-801: Verification of Dose Information Passed Through 3D-Printed Products

Purpose: When quality assurance (QA) of patient treatment beam is performed, homogeneous water equivalent phantom which has different structure from patient’s internal structure is normally used. In these days, it is possible to make structures which have same shapes of human organs with commercialization of 3D-printer. As a Result, structures with same shape of human organs made by 3D-printer could be used to test qualification of treatment beam with greater accuracy than homogeneous water phantom. In this study, we estimated the dose response of 3D-printer materials to test the probability as a humanoid phantom or new generation of compensator tool. Methods: The rectangular products with variety densities (50%, 75% and 100%) were made to verify their characteristics. The products for experiment group and solid water phantom and air for control group with 125 cubic centimeters were put on solid water phantom with enough thickness. CT image of two products were acquired to know their HU values and to know about their radiologic characteristics. 6MV beams with 500MU were exposed for each experiment. Doses were measured behind the 3D-printed products. These measured doses were compared to the results taken by TPS. Results: Absorbed dose penetrated from empty air is normalized to 100%. Doses measured from 6MV photon beams penetrated from 50%, 75% and 100% products were 99%, 96% and 84%, respectively. HU values of 50%, 75% and 100% products are about −910, −860 and −10. Conclusion: 3D-printer can produce structures which have similar characteristics with human organ. These results would be used to make similar phantoms with patient information. This work was supported by the Nuclear Safety Research Program (Grant No. 1305033 and 1403019) of the Korea Radiation Safety Foundation and the Nuclear Safety and Security Commission and Radiation Technology Development Program (2013M2A2A4027117) of the Republic of Korea.

60 APPLIED LIFE SCIENCES↗

Beam Profile Measurement in MTA Beam Line for High Pressure RF Cavity Beam Test

Recent High Pressure RF (HPRF) cavity experiment at MuCool Test Area (MTA) has used 400 MeV Linac proton beam to study the beam loading effect. When the energetic proton beam passes through the cavity, it ionizes the inside gas and produces the electrons. These electrons consume RF power inside the cavity. Number of electrons produced per cm inside the cavity (at 950 psi Hydrogen gas) per incident proton is {approx} 1200. The measurement of beam position and profile are necessary. MTA is flammable gas (Hydrogen) hazard zone so we have developed a passive beam diagnostic instrument using Chromox-6 scintillation screen and CCD camera. This paper presents quantitative information about beam position and beam profile. Neutral density filter was used to avoid saturation of CCD camera. Image data is filtered and fitted with Gaussian function to compute the beam size. The beam profile obtained from scintillation screen shall be compared with multi-wire beam profile.

08 HYDROGEN↗

Electron Recombination in a Dense Hydrogen Plasma

A high pressure hydrogen gas filled RF cavity was subjected to an intense proton beam to study the evolution of the beam induced plasma inside the cavity. Varying beam intensities, gas pressures and electric fields were tested. Beam induced ionized electrons load the cavity, thereby decreasing the accelerating gradient. The extent and duration of this degradation has been measured. A model of the recombination between ionized electrons and ions is presented, with the intent of producing a baseline for the physics inside such a cavity used in a muon accelerator. Analysis of the data taken during the summer of 2011 shows that self recombination takes place in pure hydrogen gas. The decay of the number of electrons in the cavity once the beam is turned off indicates self recombination rather than attachment to electronegative dopants or impurities. The cross section of electron recombination grows for larger clusters of hydrogen and so at the equilibrium of electron production and recombination in the cavity, processes involving H{sub 5}{sup +} or larger clusters must be taking place. The measured recombination rates during this time match or exceed the analytic predicted values. The accelerating gradient in the cavity recovers fully in time for the next beam pulse of a muon collider. Exactly what the recombination rate is and how much the gradient degrades during the 60 ns muon collider beam pulse will be extrapolated from data taken during the spring of 2012.

43 PARTICLE ACCELERATORS↗

Influence of Intense Beam in High Pressure Hydrogen Gas Filled RF Cavities

The influence of an intense beam in a high-pressure gas filled RF cavity has been measured by using a 400 MeV proton beam in the Mucool Test Area at Fermilab. The ionization process generates dense plasma in the cavity and the resultant power loss to the plasma is determined by measuring the cavity voltage on a sampling oscilloscope. The energy loss has been observed with various peak RF field gradients (E), gas pressures (p), and beam intensities in nitrogen and hydrogen gases. Observed RF energy dissipation in single electron (dw) in N{sub 2} and H{sub 2} gases was 2 10{sup -17} and 3 10{sup -17} Joules/RF cycle at E/p = 8 V/cm/Torr, respectively. More detailed dw measurement have been done in H{sub 2} gas at three different gas pressures. There is a clear discrepancy between the observed dw and analytical one. The discrepancy may be due to the gas density effect that has already been observed in various experiments.

43 PARTICLE ACCELERATORS↗

Assessment and Mitigation of Diagnostic-Generated Electromagnetic Interference at the National Ignition Facility

Electromagnetic interference (EMI) is an ever-present challenge at laser facilities such as the National Ignition Facility (NIF). The major source of EMI at such facilities is laser-target interaction that can generate intense electromagnetic fields within, and outside of, the laser target chamber. In addition, the diagnostics themselves can be a source of EMI, even interfering with themselves. In this paper we describe EMI generated by ARIANE and DIXI, present measurements, and discuss effects of the diagnostic-generated EMI on ARIANE's CCD and on a PMT nearby DIXI. Finally we present some of the efforts we have made to mitigate the effects of diagnostic-generated EMI on NIF diagnostics.

42 ENGINEERING↗

Theoretical study of transverse-longitudinal emittance coupling

The effect of a weakly coupled periodic lattice in terms of achieving emittance exchange between the transverse and longitudinal directions is investigated using the generalized Courant-Snyder theory for coupled lattices. Recently, the concept and technique of transverse-longitudinal emittance coupling have been proposed for applications in the Linac Coherent Light Source and other free-electron lasers to reduce the transverse emittance of the electron beam. Such techniques can also be applied to the driver beams for the heavy ion fusion and beam-driven high energy density physics, where the transverse emittance budget is typically tighter than the longitudinal emittance. The proposed methods consist of one or several coupling components which completely swap the emittances of one of the transverse directions and the longitudinal direction at the exit of the coupling components. The complete emittance exchange is realized in one pass through the coupling components. In the present study, we investigate the effect of a weakly coupled periodic lattice in terms of achieving emittance exchange between the transverse and longitudinal directions. A weak coupling component is introduced at every focusing lattice, and we would like to determine if such a lattice can realize the function of emittance exchange.

43 PARTICLE ACCELERATORS↗

Beam-induced Electron Loading Effects in High Pressure Cavities for a Muon Collider

Ionization cooling is a critical building block for the realization of a muon collider. To suppress breakdown in the presence of the external magnetic field, an idea of using an RF cavity filled with high pressure hydrogen gas is being considered for the cooling channel design. One possible problem expected in the high pressure RF cavity is, however, the dissipation of significant RF power through the beam-induced electrons accumulated inside the cavity. To characterize this detrimental loading effect, we develop a simplified model that relates the electron density evolution and the observed pickup voltage signal in the cavity, with consideration of several key molecular processes such as the formation of the polyatomic molecules, recombination and attachment. This model is expected to be compared with the actual beam test of the cavity in the MuCool Test Area (MTA) of Fermilab.

43 PARTICLE ACCELERATORS↗

The MuCool Test Area and RF Program

The MuCool RF Program focuses on the study of normal conducting RF structures operating in high magnetic field for applications in muon ionization cooling for Neutrino Factories and Muon Colliders. Here we give an overview of the program, which includes a description of the test facility and its capabilities, the current test program, and the status of a cavity that can be rotated in the magnetic field, which allows for a detailed study of the maximum stable operating gradient vs. magnetic field strength and angle.

43 PARTICLE ACCELERATORS↗

Rectangular Box Cavity Tests in Magnetic Field for Muon Cooling

Muon cooling requires high-gradient normal conducting cavities operating in multi-Tesla magnetic fields for muon beam focusing in an ionization cooling channel. Recent experience with an 805-MHz pillbox cavity at the Fermilab MuCool Test Area has shown a significant drop in accelerating field performance for the case of parallel electric and magnetic fields. It has been suggested that having the magnetic field perpendicular to the electric field should provide magnetic insulation and suppress breakdown. An 805-MHz Cu rectangular box cavity was built for testing with the fields perpendicular. It was mounted on an adjustable support to vary the angle between the rf electric and external magnetic field. We report on the design and initial operation of the rectangular box cavity.

43 PARTICLE ACCELERATORS↗

Beam Test of a High Pressure Cavity for a Muon Collider

To demonstrate the feasibility of a high pressure RF cavity for use in the cooling channel of a muon collider, an experimental setup that utilizes 400-MeV Fermilab linac proton beam has been developed. In this paper, we describe the beam diagnostics and the collimator system for the experiment, and report the initial results of the beam commissioning. The transient response of the cavity to the beam is measured by the electric and magnetic pickup probes, and the beam-gas interaction is monitored by the optical diagnostic system composed of a spectrometer and two PMTs.

43 PARTICLE ACCELERATORS↗

Study of Electron Swarm in High Pressure Hydrogen Gas Filled RF Cavities

A high pressure hydrogen gas filled RF cavity has been proposed for use in the muon collection system for a muon collider. It allows for high electric field gradients in RF cavities located in strong magnetic fields, a condition frequently encountered in a muon cooling channel. In addition, an intense muon beam will generate an electron swarm via the ionization process in the cavity. A large amount of RF power will be consumed into the swarm. We show the results from our studies of the HV RF breakdown in a cavity without a beam and present some results on the resulting electron swarm dynamics. This is preliminary to actual beam tests which will take place late in 2010.

43 PARTICLE ACCELERATORS↗