Engineering Papers⌕ Search

Engineering topics

Chuang, Cynthia

Publications and source records attributed to Chuang, Cynthia.

The need for application-based adaptation of deformable image registration

Purpose: To utilize a deformable phantom to objectively evaluate the accuracy of 11 different deformable image registration (DIR) algorithms. Methods: The phantom represents an axial plane of the pelvic anatomy. Urethane plastic serves as the bony anatomy and urethane rubber with three levels of Hounsfield units (HU) is used to represent fat and organs, including the prostate. A plastic insert is placed into the phantom to simulate bladder filling. Nonradiopaque markers reside on the phantom surface. Optical camera images of these markers are used to measure the positions and determine the deformation from the bladder insert. Eleven different DIR algorithms are applied to the full and empty-bladder computed tomography images of the phantom (fixed and moving volumes, respectively) to calculate the deformation. The algorithms include those from MIM Software (MIM) and Velocity Medical Solutions (VEL) and nine different implementations from the deformable image registration and adaptive radiotherapy toolbox for Matlab. These algorithms warp one image to make it similar to another, but must utilize a method for regularization to avoid physically unrealistic deformation scenarios. The mean absolute difference (MAD) between the HUs at the marker locations on one image and the calculated location on the other serves as a metric to evaluate the balance between image similarity and regularization. To demonstrate the effect of regularization on registration accuracy, an additional beta version of MIM was created with a variable smoothness factor that controls the emphasis of the algorithm on regularization. The distance to agreement between the measured and calculated marker deformations is used to compare the overall spatial accuracy of the DIR algorithms. This overall spatial accuracy is also utilized to evaluate the phantom geometry and the ability of the phantom soft-tissue heterogeneity to represent patient data. To evaluate the ability of the DIR algorithms to accurately transfer anatomical contours, the rectum is delineated on both the fixed and moving images. A Dice similarity coefficient is then calculated between the contour on the fixed image and that transferred, via the calculated deformation, from the moving to the fixed image. Results: The phantom possesses sufficient soft-tissue heterogeneity to act as a proxy for patient data. Large discrepancies appear between the algorithms and the measured ground-truth deformation. VEL yields the smallest mean spatial error and a Dice coefficient of 0.90. MIM produces the lowest MAD value and the highest Dice coefficient of 0.96, but creates the largest spatial errors. Increasing the MIM smoothness factor above the default value improves the overall spatial accuracy, but the factor associated with the lowest mean error decreases the Dice coefficient to 0.85. Conclusions: Different applications of DIR require disparate balances between image similarity and regularization. A DIR algorithm that is optimized only for its ability to transfer anatomical contours will yield large deformation errors in homogeneous regions, which is problematic for dose mapping. For this reason, these algorithms must be tested for their overall spatial accuracy. The developed phantom is an objective tool for this purpose.

60 APPLIED LIFE SCIENCES↗

Stereotactic Body Radiotherapy as Monotherapy or Post-External Beam Radiotherapy Boost for Prostate Cancer: Technique, Early Toxicity, and PSA Response

Purpose: High dose rate (HDR) brachytherapy has been established as an excellent monotherapy or after external-beam radiotherapy (EBRT) boost treatment for prostate cancer (PCa). Recently, dosimetric studies have demonstrated the potential for achieving similar dosimetry with stereotactic body radiotherapy (SBRT) compared with HDR brachytherapy. Here, we report our technique, PSA nadir, and acute and late toxicity with SBRT as monotherapy and post-EBRT boost for PCa using HDR brachytherapy fractionation. Patients and Methods: To date, 38 patients have been treated with SBRT at University of California-San Francisco with a minimum follow-up of 12 months. Twenty of 38 patients were treated with SBRT monotherapy (9.5 Gy Multiplication-Sign 4 fractions), and 18 were treated with SBRT boost (9.5 Gy Multiplication-Sign 2 fractions) post-EBRT and androgen deprivation therapy. PSA nadir to date for 44 HDR brachytherapy boost patients with disease characteristics similar to the SBRT boost cohort was also analyzed as a descriptive comparison. Results: SBRT was well tolerated. With a median follow-up of 18.3 months (range, 12.6-43.5), 42% and 11% of patients had acute Grade 2 gastrourinary and gastrointestinal toxicity, respectively, with no Grade 3 or higher acute toxicity to date. Two patients experienced late Grade 3 GU toxicity. All patients are without evidence of biochemical or clinical progression to date, and favorably low PSA nadirs have been observed with a current median PSA nadir of 0.35 ng/mL (range, <0.01-2.1) for all patients (0.47 ng/mL, range, 0.2-2.1 for the monotherapy cohort; 0.10 ng/mL, range, 0.01-0.5 for the boost cohort). With a median follow-up of 48.6 months (range, 16.4-87.8), the comparable HDR brachytherapy boost cohort has achieved a median PSA nadir of 0.09 ng/mL (range, 0.0-3.3). Conclusions: Early results with SBRT monotherapy and post-EBRT boost for PCa demonstrate acceptable PSA response and minimal toxicity. PSA nadir with SBRT boost appears comparable to those achieved with HDR brachytherapy boost.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Physics strategies for sparing neural stem cells during whole-brain radiation treatments

Purpose: Currently, there are no successful long-term treatments or preventive strategies for radiation-induced cognitive impairments, and only a few possibilities have been suggested. One such approach involves reducing the dose to neural stem cell compartments (within and outside of the hippocampus) during whole-brain radiation treatments for brain metastases. This study investigates the fundamental physics issues associated with the sparing of neural stem cells during photon radiotherapy for brain metastases. Methods: Several factors influence the stem cell dose: intracranial scattering, collimator leakage, beam energy, and total number of beams. The relative importance of these factors is investigated through a set of radiation therapy plans, which are all variations of an initial 6 MV intensity-modulated radiation therapy (IMRT) plan designed to simultaneously deliver a whole-brain dose of 30 Gy and maximally reduce stem cell compartment dose. Additionally, an in-house leaf segmentation algorithm was developed that utilizes jaw motion to minimize the collimator leakage. Results: The plans are all normalized such that 50% of the PTV receives 30 Gy. For the initial 6 MV IMRT plan, 50% of the stem cells receive a dose greater than 6.3 Gy. Calculations indicate that 3.6 Gy of this dose originates from intracranial scattering. The jaw-tracking segmentation algorithm, used in conjunction with direct machine parameter optimization, reduces the 50% stem cell dose to 4.3 and 3.7 Gy for 6 and 10 MV treatment beams, respectively. Conclusions: Intracranial scattering alone is responsible for a large dose contribution to the stem cell compartment. It is, therefore, important to minimize other contributing factors, particularly the collimator leakage, to maximally reduce dose to these critical structures. The use of collimator jaw tracking in conjunction with modern collimators can minimize this leakage.

61 RADIATION PROTECTION AND DOSIMETRY↗

A two-dimensional deformable phantom for quantitatively verifying deformation algorithms

Purpose: The incorporation of deformable image registration into the treatment planning process is rapidly advancing. For this reason, the methods used to verify the underlying deformation algorithms must evolve equally fast. This manuscript proposes a two-dimensional deformable phantom, which can objectively verify the accuracy of deformation algorithms, as the next step for improving these techniques. Methods: The phantom represents a single plane of the anatomy for a head and neck patient. Inflation of a balloon catheter inside the phantom simulates tumor growth. CT and camera images of the phantom are acquired before and after its deformation. Nonradiopaque markers reside on the surface of the deformable anatomy and are visible through an acrylic plate, which enables an optical camera to measure their positions; thus, establishing the ground-truth deformation. This measured deformation is directly compared to the predictions of deformation algorithms, using several similarity metrics. The ratio of the number of points with more than a 3 mm deformation error over the number that are deformed by more than 3 mm is used for an error metric to evaluate algorithm accuracy. Results: An optical method of characterizing deformation has been successfully demonstrated. For the tests of this method, the balloon catheter deforms 32 out of the 54 surface markers by more than 3 mm. Different deformation errors result from the different similarity metrics. The most accurate deformation predictions had an error of 75%. Conclusions: The results presented here demonstrate the utility of the phantom for objectively verifying deformation algorithms and determining which is the most accurate. They also indicate that the phantom would benefit from more electron density heterogeneity. The reduction of the deformable anatomy to a two-dimensional system allows for the use of nonradiopaque markers, which do not influence deformation algorithms. This is the fundamental advantage of this verification technique.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dose Gradient Near Target-Normal Structure Interface for Nonisocentric CyberKnife and Isocentric Intensity-Modulated Body Radiotherapy for Prostate Cancer

Purpose: The treatment planning quality between nonisocentric CyberKnife (CK) and isocentric intensity modulation treatment was studied for hypofractionated prostate body radiotherapy. In particular, the dose gradient across the target and the critical structures such as the rectum and bladder was characterized. Methods and Materials: In the present study, patients treated with CK underwent repeat planning for nine fixed-field intensity-modulated radiotherapy (IMRT) using identical contour sets and dose-volume constraints. To calculate the dose falloff, the clinical target volume contours were expanded 30 mm anteriorly and posteriorly and 50 mm uniformly in other directions for all patients in the CK and IMRT plans. Results: We found that all the plans satisfied the dose-volume constraints, with the CK plans showing significantly better conformity than the IMRT plans at a relative greater dose inhomogeneity. The rectal and bladder volumes receiving a low dose were also lower for CK than for IMRT. The average conformity index, the ratio of the prescription isodose volume and clinical target volume, was 1.18 {+-} 0.08 for the CK plans vs. 1.44 {+-} 0.11 for the IMRT plans. The average homogeneity index, the ratio of the maximal dose and the prescribed dose to the clinical target volume, was 1.45 {+-} 0.12 for the CK plans vs. 1.28 {+-} 0.06 for the IMRT plans. The average percentage of dose falloff was 2.9% {+-} 0.8%/mm for CK and 3.1% {+-} 1.0%/mm for IMRT in the anterior direction, 3.8% {+-} 1.6%/mm for CK and 3.2% {+-} 1.9%/mm for IMRT in the posterior direction, and 3.6% {+-} 0.4% for CK and 3.6% {+-} 0.4% for IMRT in all directions. Conclusion: Nonisocentric CK was as capable of producing equivalent fast dose falloff as high-number fixed-field IMRT delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Equivalence in Dose Fall-Off for Isocentric and Nonisocentric Intracranial Treatment Modalities and Its Impact on Dose Fractionation Schemes

Purpose: To investigate whether dose fall-off characteristics would be significantly different among intracranial radiosurgery modalities and the influence of these characteristics on fractionation schemes in terms of normal tissue sparing. Methods and Materials: An analytic model was developed to measure dose fall-off characteristics near the target independent of treatment modalities. Variations in the peripheral dose fall-off characteristics were then examined and compared for intracranial tumors treated with Gamma Knife, Cyberknife, or Novalis LINAC-based system. Equivalent uniform biologic effective dose (EUBED) for the normal brain tissue was calculated. Functional dependence of the normal brain EUBED on varying numbers of fractions (1 to 30) was studied for the three modalities. Results: The derived model fitted remarkably well for all the cases (R{sup 2} > 0.99). No statistically significant differences in the dose fall-off relationships were found between the three modalities. Based on the extent of variations in the dose fall-off curves, normal brain EUBED was found to decrease with increasing number of fractions for the targets, with alpha/beta ranging from 10 to 20. This decrease was most pronounced for hypofractionated treatments with fewer than 10 fractions. Additionally, EUBED was found to increase slightly with increasing number of fractions for targets with alpha/beta ranging from 2 to 5. Conclusion: Nearly identical dose fall-off characteristics were found for the Gamma Knife, Cyberknife, and Novalis systems. Based on EUBED calculations, normal brain sparing was found to favor hypofractionated treatments for fast-growing tumors with alpha/beta ranging from 10 to 20 and single fraction treatment for abnormal tissues with low alpha/beta values such as alpha/beta = 2.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nonrandom Intrafraction Target Motions and General Strategy for Correction of Spine Stereotactic Body Radiotherapy

Purpose: To characterize nonrandom intrafraction target motions for spine stereotactic body radiotherapy and to develop a method of correction via image guidance. The dependence of target motions, as well as the effectiveness of the correction strategy for lesions of different locations within the spine, was analyzed. Methods and Materials: Intrafraction target motions for 64 targets in 64 patients treated with a total of 233 fractions were analyzed. Based on the target location, the cases were divided into three groups, i.e., cervical (n = 20 patients), thoracic (n = 20 patients), or lumbar-sacrum (n = 24 patients) lesions. For each case, time-lag autocorrelation analysis was performed for each degree of freedom of motion that included both translations (x, y, and z shifts) and rotations (roll, yaw, and pitch). A general correction strategy based on periodic interventions was derived to determine the time interval required between two adjacent interventions, to overcome the patient-specific target motions. Results: Nonrandom target motions were detected for 100% of cases regardless of target locations. Cervical spine targets were found to possess the highest incidence of nonrandom target motion compared with thoracic and lumbar-sacral lesions (p < 0.001). The average time needed to maintain the target motion to within 1 mm of translation or 1 deg. of rotational deviation was 5.5 min, 5.9 min, and 7.1 min for cervical, thoracic, and lumbar-sacrum locations, respectively (at 95% confidence level). Conclusions: A high incidence of nonrandom intrafraction target motions was found for spine stereotactic body radiotherapy treatments. Periodic interventions at approximately every 5 minutes or less were needed to overcome such motions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Body Radiotherapy Is Effective Salvage Therapy for Patients With Prior Radiation of Spinal Metastases

Purpose: To provide actuarial outcomes and dosimetric data for spinal/paraspinal metastases, with and without prior radiation, treated with stereotactic body radiotherapy (SBRT). Methods and Materials: A total of 39 consecutive patients (60 metastases) were treated with SBRT between April 2003 and August 2006 and retrospectively reviewed. In all, 23 of 60 tumors had no previous radiation (unirradiated) and 37/60 tumors had previous irradiation (reirradiated). Of 37 reirradiated tumors, 31 were treated for 'salvage' given image-based tumor progression. Local failure was defined as progression by imaging and/or clinically. Results: At last follow-up, 19 patients were deceased. Median patient survival time measured was 21 months (95% CI = 8-27 months), and the 2-year survival probability was 45%. The median total dose prescribed was 24 Gy in three fractions prescribed to the 67% and 60% isodose for the unirradiated and reirradiated cohorts, respectively. The median tumor follow-up for the unirradiated and reirradiated group was 9 months (range, 1-26) and 7 months (range, 1-48) respectively. Eight of 60 tumors have progressed, and the 1- and 2-year progression-free probability (PFP) was 85% and 69%, respectively. For the salvage group the 1 year PFP was 96%. There was no significant difference in overall survival or PFP between the salvage reirradiated vs. all other tumors treated (p = 0.08 and p = 0.31, respectively). In six of eight failures the minimum distance from the tumor to the thecal sac was {<=}1 mm. Of 60 tumors treated, 39 have {>=}6 months follow-up and no radiation-induced myelopathy or radiculopathy has occurred. Conclusion: Spine SBRT has shown preliminary efficacy and safety in patients with image-based progression of previously irradiated metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Whole-procedure clinical accuracy of Gamma Knife treatments of large lesions

The mechanical accuracy of Gamma Knife radiosurgery based on single-isocenter measurement has been established to within 0.3 mm. However, the full delivery accuracy for Gamma Knife treatments of large lesions has only been estimated via the quadrature-sum analysis. In this study, the authors directly measured the whole-procedure accuracy for Gamma Knife treatments of large lesions to examine the validity of such estimation. The measurements were conducted on a head-phantom simulating the whole treatment procedure that included frame placement, computed tomography imaging, treatment planning, and treatment delivery. The results of the measurements were compared with the dose calculations from the treatment planning system. Average agreements of 0.1-1.6 mm for the isodose lines ranging from 25% to 90% of the maximum dose were found despite potentially large contributing uncertainties such as 3-mm imaging resolution, 2-mm dose grid size, 1-mm frame registration, multi-isocenter deliveries, etc. The results of our measurements were found to be significantly smaller (>50%) than the calculated value based on the quadrature-sum analysis. In conclusion, Gamma Knife treatments of large lesions can be delivered much more accurately than predicted from the quadrature-sum analysis of major sources of uncertainties from each step of the delivery chain.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Split-Volume Treatment Planning of Multiple Consecutive Vertebral Body Metastases for Cyberknife Image-Guided Robotic Radiosurgery

Cyberknife treatment planning of multiple consecutive vertebral body metastases is challenging due to large target volumes adjacent to critical normal tissues. A split-volume treatment planning technique was developed to improve the treatment plan quality of such lesions. Treatment plans were generated for 1 to 5 consecutive thoracic vertebral bodies (CVBM) prescribing a total dose of 24 Gy in 3 fractions. The planning target volume (PTV) consisted of the entire vertebral body(ies). Treatment plans were generated considering both the de novo clinical scenario (no prior radiation), imposing a dose limit of 8 Gy to 1 cc of spinal cord, and the retreatment scenario (prior radiation) with a dose limit of 3 Gy to 1 cc of spinal cord. The split-volume planning technique was compared with the standard full-volume technique only for targets ranging from 2 to 5 CVBM in length. The primary endpoint was to obtain best PTV coverage by the 24 Gy prescription isodose line. A total of 18 treatment plans were generated (10 standard and 8 split-volume). PTV coverage by the 24-Gy isodose line worsened consistently as the number of CVBM increased for both the de novo and retreatment scenario. Split-volume planning was achieved by introducing a 0.5-cm gap, splitting the standard full-volume PTV into 2 equal length PTVs. In every case, split-volume planning resulted in improved PTV coverage by the 24-Gy isodose line ranging from 4% to 12% for the de novo scenario and, 8% to 17% for the retreatment scenario. We did not observe a significant trend for increased monitor units required, or higher doses to spinal cord or esophagus, with split-volume planning. Split-volume treatment planning significantly improves Cyberknife treatment plan quality for CVBM, as compared to the standard technique. This technique may be of particular importance in clinical situations where stringent spinal cord dose limits are required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulated real time image guided intrafraction tracking-delivery for hypofractionated prostate IMRT

Hypofractionated stereotactic body radiotherapy (SBRT) has been tested for prostate cancer radiotherapy. This study aims to investigate the dosimetric effects of intrafraction prostate motion on the target and the normal structures for SBRT. For prostate cancer patients treated with an image-tracking CyberKnife system, the intrafraction prostate movements were recorded during 50-70 min treatment time. Based on the recorded intrafraction prostate movements, treatment plans were created for these cases using intensity modulated beams while scaling the average time patterns from the CyberKnife treatment to simulate hypofractionated intensity modulated radiotherapy (IMRT) delivery. The effect of delivery time on the intrafraction organ motion was investigated. For a nominal single fraction delivery of 9.5 Gy with IMRT, we found that the dosimetric effect of the intrafraction prostate movement is case dependent. For most cases, the dose volume histograms exhibited very small changes from the treatment plans that assumed no intrafractional prostate motion when the maximum intrafraction movements were within {+-}5 mm. However, when sporadic prostate movements greater than 5 mm were present in any one direction, significant changes were found. For example, the V{sub 100%} for the prostate could be reduced by more than 10% to less than 85% of the prostate volume coverage. If these large movements could be excluded by some active correction strategies, then the average V{sub 100%} for the simulated plan could be restored to within approximately 2% of the ideal treatment plans. On average, the sporadic intrafraction motion has less dosimetric impact on the prolonged treatment delivery versus fast treatment delivery. For example, the average V{sub 100%} for the clinical target volume was reduced from the original 95.1% to 92.1{+-} 3.7% for prolonged treatment, and to 91.3{+-}5.4% when the treatment time was shortened by 50%. Due to the observed large sporadic prostate motions, we conclude that an on-line target motion monitoring and correction strategy is necessary to implement hypofractionated SBRT with intensity modulated beams for prostate cancer treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of residual target motion for image-tracked spine radiosurgery

A quality assurance method was developed to investigate the effects of residual target motion for hypofractionated spine radiosurgery. The residual target motion (target movement between successive image-guided corrections) was measured on-line via dual x-ray imagers for patients treated with CyberKnife (Accuray, Inc., Sunnyvale, CA), a robotic linear accelerator with intrafractional image-tracking capability. The six degree-of-freedom characteristics of the residual target motion were analyzed, the effects of such motion on patient treatment delivery were investigated by incorporating the probability distribution of the residual motion into the treatment planning dose calculations, and deviations of the doses from those originally planned were calculated. Measurements using a programmable motion phantom were also carried out and compared with the static treatment plan calculations. It was found that the residual target motions were patient specific and typically on the order of 2 mm. The measured dose distributions incorporating the residual target motion also exhibited 2.0 mm discrepancy at the prescription isodose level when compared with the static treatment plan calculations. For certain patients, residual errors introduced significant uncertainties ({approx}1 Gy) for the dose delivered to the spinal cord, especially at the high dose levels covering a small volume of the spinal cord (e.g., 0.1 cc). In such cases, stringent cord constraints and frequent monitoring of the target position should be implemented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗