TracKlinic: Diagnosis of Challenge Factors in Visual Tracking

Generic visual object tracking is difficult due to many challenge factors (e.g., occlusion, blur, etc.). Each of these factors may cause serious problems for a tracker, and when they work together can make things even more complicated. Despite a great amount of efforts devoted to understanding the behavior of trackers, reliable and quantifiable ways for studying the per factor tracking behavior remain barely available. Addressing this issue, in this paper we contribute to the community a tracking diagnosis toolkit, TracKlinic, for diagnosis of challenge factors of tracking algorithms. TracKlinic consists of two novel components focusing on the data and analysis aspects, respectively. For the data component, we carefully prepare a set of 2,390 annotated videos, each involving one and only one major challenge factor. When analyzing an algorithm for a specific challenge factor, such one-factor-per-sequence rule greatly inhibits the disturbance from other factors and consequently leads to more faithful analysis. For the analysis component, given the tracking results on all sequences, it investigates the behavior of the tracker under each individual factor and generates the report automatically. With TracKlinic, a thorough study is conducted on ten state-of-the-art trackers on nine challenge factors (including two compound ones). The results suggest that, heavy shape variation and occlusion are the two most challenging factors faced by most trackers. Besides, out-of-view, though does not happen frequently, is often fatal. By sharing TracKlinic1, we expect to make it much easier for diagnosing tracking algorithms, and to thus facilitate developing better ones.

97 MATHEMATICS AND COMPUTING↗

Status Update of the MAJORANA DEMONSTRATOR Neutrinoless Double Beta Decay Experiment

Neutrinoless double beta decay searches play a major role in determining neutrino properties, in particular the Majorana or Dirac nature of the neutrino and the absolute scale of the neutrino mass. The consequences of these searches go beyond neutrino physics, with implications for Grand Unification and leptogenesis. The \textsc{Majorana} Collaboration is assembling a low-background array of high purity Germanium (HPGe) detectors to search for neutrinoless double-beta decay in $^{76}$Ge. The \textsc{Majorana Demonstrator}, which is currently being constructed and commissioned at the Sanford Underground Research Facility in Lead, South Dakota, will contain 44 kg (30 kg enriched in $^{76}$Ge) of HPGe detectors. Its primary goal is to demonstrate the scalability and background required for a tonne-scale Ge experiment. This is accomplished via a modular design and projected background of less than 3 cnts/tonne-yr in the region of interest. The experiment is currently taking data with the first of its enriched detectors.

Gruszko, J↗

Determination of Nickel Species in Stack Emissions from Eight Residual Oil-Fired Utility Steam-Generating Units

XAFS spectroscopy has been used to determine the Ni species in particulate matter collected on quartz thimble filters in the stacks of eight residual (No. 6 fuel) oil-burning electric utility steam-generating units. Proper speciation of nickel in emitted particulate matter is necessary to correctly anticipate potential health risks. Analysis of the spectroscopic data using least-squares linear combination methods and a newly developed method specific for small quantities of Ni sulfide compounds in such emissions show that potentially carcinogenic Ni sulfide compounds are absent within the detection limits of the method ({le}3% of the total Ni) in the particulate matter samples investigated. In addition to the major nickel sulfate phase (NiSO{sub 4} {center_dot} 6H{sub 2}O), lesser amounts of (Ni,Mg)O and/or NiFe{sub 2}O{sub 4} were also identified in most emission samples. On the basis of the results from these emission characterization studies, the appropriateness of the U.S. Environmental Protection Agency's assumption that the Ni compound mixture emitted from residual oil-fired power plants is 50% as carcinogenic as nickel subsulfide (Ni{sub 3}S{sub 2}) should be re-evaluated.

54 ENVIRONMENTAL SCIENCES↗

Beam-based Feedback for the Linac Coherent Light Source

Beam-based feedback control loops are required by the Linac Coherent Light Source (LCLS) program in order to provide fast, single-pulse stabilization of beam parameters. Eight transverse feedback loops, a 6 x 6 longitudinal feedback loop, and a loop to maintain the electron bunch charge were successfully prototyped in MATLAB for the LCLS, and have been maintaining stability of the LCLS electron beam at beam rates up to 30Hz. In the final commissioning phase of LCLS the beam will be operating at up to 120Hz. In order to run the feedback loops at beam rate, the feedback loops will be implemented in EPICS IOCs with a dedicated ethernet multi-cast network. This paper will discuss the design of the beam-based Fast Feedback System for LCLS. Topics include MATLAB feedback prototyping, algorithm for 120Hz feedback, network design for fast data transport, actuator and sensor design for single-pulse control and sensor readback, and feedback configuration and runtime control.

43 PARTICLE ACCELERATORS↗

XAL-Based Applications and Online Models for LCLS

XAL, a high-level accelerator application framework originally developed at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory, has been adopted by the Linac Coherent Light Source (LCLS) project. The work includes proper relational database schema modification to better suit XAL configuration data requirement, addition of new device types for LCLS online modeling purpose, longitudinal coordinate system change to better represent the LCLS electron beam rather than proton or ion beam in the original SNS XAL design, intensively benchmark with MAD and present SLC modeling system for the online model, and various new features to the XAL framework. Storing online model data in a relational database and providing universal access methods for other applications is also described here.

43 PARTICLE ACCELERATORS↗

XAL Adoption Experience at LCLS

XAL is a high level accelerator application framework originally developed by the Spallation Neutron Source (SNS), Oak Ridge National Laboratory. The XAL framework provides generic hierarchical view for an accelerator as well as many utility tools. In XAL, a built-in physics model calculates either single particle or beam envelope tracking for physics parameters. Modifications to the original XAL model are necessary for the Linac Coherent Light Source (LCLS). Work was done to manipulate MAD deck output within a database in support of the XAL configuration and model. The XAL graphical user interface has been replaced by a SLAC specific design. New applications based on the framework are also discussed in this paper.

43 PARTICLE ACCELERATORS↗

Surface and Downhole Prospecting Tools for Planetary Exploration: Tests of Neutron and Gamma Ray Probes - Research Paper

The ability to locate and characterize icy deposits and other hydrogenous materials on the Moon and Mars will help us understand the distribution of water and, therefore, possible habitats at Mars, and may help us locate primitive prebiotic compounds at the Moon’s poles. We have developed a rover-borne neutron probe that localizes a near-surface icy deposit and provides information about its burial depth and abundance. We have also developed a borehole neutron probe to determine the stratigraphy of hydrogenous subsurface layers while operating within a drill string segment. In our field tests, we have used a neutron source to “illuminate” surrounding materials and gauge the instruments’ efficacy, and we can simulate accurately the observed instrument responses using a Monte Carlo nuclear transport code (MCNPX). An active neutron source would not be needed for lunar or martian near-surface exploration: cosmic-ray interactions provide sufficient neutron flux to depths of several meters and yield better depth and abundance sensitivity than an active source. However, for deep drilling (>10 m depth), a source is required. We also present initial tests of a borehole gamma ray lithodensity tool and demonstrate its utility in determining soil or rock densities and composition.

58 GEOSCIENCES↗

High-Level Application Framework for LCLS

A framework for high level accelerator application software is being developed for the Linac Coherent Light Source (LCLS). The framework is based on plug-in technology developed by an open source project, Eclipse. Many existing functionalities provided by Eclipse are available to high-level applications written within this framework. The framework also contains static data storage configuration and dynamic data connectivity. Because the framework is Eclipse-based, it is highly compatible with any other Eclipse plug-ins. The entire infrastructure of the software framework will be presented. Planned applications and plug-ins based on the framework are also presented.

43 PARTICLE ACCELERATORS↗