Engineering PapersSearch

Engineering topics

Christine Jerome

Publications and source records attributed to Christine Jerome.

Considerations for Range of Motion Testing During Spacesuit Mobility Characterization

Mobility is a critical aspect for spacesuits as it directly influences how astronauts can perform tasks safely and efficiently, while wearing the pressurized suit. Spacesuit motion is dissimilar to human movement and consists of unique movement patterns as result of pressurization and the complex mechanical joint configurations. Thus, it is important to quantify the variations in suited movement patterns and the resulting performance of the wearer for the evaluation of the spacesuit itself and hardware interfaces such as payloads and tools. Traditionally, an individual body joint is assessed for the segment-wise range of motion. For example, the knee is measured through an isolated maneuvering of the joint between the max-to-max positions (e.g., flexion/extension), and the outcome represents the mobility capabilities. These measurements are often conducted using optical motion capture system with respect to anatomical planes. However, there are several considerations for range of motion assessments that are unique to the spacesuit. The purpose of this paper is to describe and provide examples of these additional challenges in representing spacesuit mobility capabilities. Specifically, joint mobility and the variations in suit movement patterns were investigated and compared between functional tasks and isolated range of motion measurements. Motion capture data from the next-gen spacesuit design verification testing was evaluated to compare isolated range of motion tasks to functional tasks, such as one-knee kneeling and squatting. The trajectories from the upper and lower body joint centers with respect to the spacesuit hardware were also calculated. Additionally, the joint trajectories for various functional tasks are presented and compared against the isolated range of motion measurements. In general, range of motion differs between isolated and functional tasks, where functional tasks may even induce greater joint angle excursions. Additionally, there is a large variation in joint range of motion across functional tasks. Combined with several relevant factors (spacesuit fit, physical strength, simulation facility, etc.), spacesuit mobility characterization efforts will need to incorporate the specific contexts, such as task demands and movement mechanisms, when evaluating range of motion assessments.

Linh Q Vu

Advanced Space Suit Sizing Considerations

Fitting a space suit to a person could be considered an art form. Establishing a repeatable fitcheck process to accommodate the full anthropometric range of test subjects for a single suit design is a critical process to be able to prove suit functionality. Suited test subjects can have different preferences on how they fit inside a suit, and different suited test environments can lead to differences in certain suit sizing accommodations. Throughout this paper, the process of achieving an acceptable suit fit for test subjects will be discussed, along with sizing considerations for changes in suit design and test environments. Lessons learned from the Exploration Extravehicular Mobility Unit (xEMU) will be used to describe specific examples, along with key takeaways from additional NASA prototype mobility space suits. The suit fitcheck process starts with utilizing the anthropometric measurements of a test subject to evaluate their relation to the dimensions of space suit hardware in creating a predicted suit sizing configuration. From here, subjective comments and test team observations drive iterations to the suit sizing configuration to culminate in an acceptable suit fit for performance of further test evaluations. Understanding the relation of subjective comments to their impact on altering suit sizing is critical in establishing an acceptable suit fit.

spacesuit

Development of Weigh-Out Process and Evaluations for Underwater Partial Gravity Simulations

For the upcoming Artemis lunar missions, astronauts will need to train in a spacesuit where partial gravity can be simulated such as the NASA Neutral Buoyancy Lab (NBL). At the NBL, dive weights and foam can be added around the spacesuit to attain a satisfactory center of buoyancy (CB) and center of gravity (CG) location to simulate the lunar gravity (1/6thG) effects. If CG and CB are not co-located properly, incorrect righting moments can be introduced, and both simulation quality and EVA task performance can be impaired. Based on the findings from the initial testing using xEMU spacesuits, it was observed that the weigh-out method (i.e., determination of the weights and foam quantities and position) needed further development to improve the simulation quality, especially for the subjects who experienced excessive instability. This paper aims to present the on-going effort to improve the weigh-out process for enabling NBL lunar EVA simulations. For this effort, a human-suit model was created to use suit CAD and 3D human body scans to estimate both CB and CG location for each suited subject. NBL weigh-out testing was performed to characterize the effects of CG and CB positioning, in which the 3D human-suit model was used to determine optimal weigh-out combinations of weights and foam. Postural, balance, and subjective feedback were gathered for each weigh-out configuration. The results indicated that, as the CB was shifted higher and the CB and CG located closer to each other, the subject tended to be more stable and their EVA performance improved. A high CB location was then prioritized across 4 additional subjects in both small and large size spacesuits. When compared to the initial xEMU test series, improved performance was observed across all subjects as the CB moved higher and aligned closer to the system CG.

Pouyan Sabahi