Short Paper: Frequency Regulation Services from Connected Residential Devices: Preprint

In this paper, we demonstrate the potential benefits that residential buildings can provide for frequency regulation services in the electric power grid. In a hardware-in-the- loop (HIL) implementation, simulated homes along with a physical laboratory home are coordinated via a grid aggregator, and it is shown that their aggregate response has the potential to follow the regulation signal on a timescale of seconds. Connected (communication-enabled), devices in the National Renewable Energy Laboratory's (NREL's) Energy Systems Integration Facility (ESIF) received demand response (DR) requests from a grid aggregator, and the devices responded accordingly to meet the signal while satisfying user comfort bounds and physical hardware limitations. Future research will address the issues of cybersecurity threats, participation rates, and reducing equipment wear-and-tear while providing grid services.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Frequency Regulation Services from Connected Residential Devices: Short Paper

In this paper, we demonstrate the potential benefits that residential buildings can provide for frequency regulation services in the electric power grid. In a hardware-in-the- loop (HIL) implementation, simulated homes along with a physical laboratory home are coordinated via a grid aggregator, and it is shown that their aggregate response has the potential to follow the regulation signal on a timescale of seconds. Connected (communication-enabled), devices in the National Renewable Energy Laboratory's (NREL's) Energy Systems Integration Facility (ESIF) received demand response (DR) requests from a grid aggregator, and the devices responded accordingly to meet the signal while satisfying user comfort bounds and physical hardware limitations. Future research will address the issues of cybersecurity threats, participation rates, and reducing equipment wear-and-tear while providing grid services.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Moisture Modeling: Effective Moisture Penetration Depth Versus Effective Capacitance

This paper compares two moisture models in the context of residential whole-building simulations - the effective moisture penetration depth (EMPD) model and the effective capacitance (EC) model. Previous research has shown that the EMPD model provides a more physically realistic response to humidity-load fluctuations than the EC model. But it is unclear how the choice of moisture model affects overall conclusions informing building design and equipment selection. In this study, the models are evaluated based on their ability to predict relative humidity, predict energy use, and to select HVAC equipment. Whole building simulations indicate that the EC and EMPD models are not equivalent, and that combining the capacitance of the building materials with the indoor air capacitance in the EC model is the root cause of this discrepancy. It means that the EC model cannot dampen humidity loads of different frequencies. This study also showed that a simulation using a certain value of EC in one city can agree with the EMPD results, but that the same EC value in a different city may not agree with the EMPD results. However, the results showed that some conclusions drawn from simulations using the EMPD model and the EC model may often be the same, even if the results differ.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Grid Connected Functionality

Dataset demonstrating the potential benefits that residential buildings can provide for frequency regulation services in the electric power grid. In a hardware-in-the-loop (HIL) implementation, simulated homes along with a physical laboratory home are coordinated via a grid aggregator, and it is shown that their aggregate response has the potential to follow the regulation signal on a timescale of seconds. Connected (communication-enabled), devices in the National Renewable Energy Laboratory's (NREL's) Energy Systems Integration Facility (ESIF) received demand response (DR) requests from a grid aggregator, and the devices responded accordingly to meet the signal while satisfying user comfort bounds and physical hardware limitations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Annual Energy Savings and Thermal Comfort of Autonomously Heated and Cooled Office Chairs

Energy use in offices buildings is largely driven by air conditioning demands. But the optimal temperature is not the same for all building occupants, leading to the infamous thermostat war. And many occupants have independently overcome building comfort weaknesses with their own space heaters or fans. NREL tested is a customized office chair that automatically heats and cools the occupant along the seat and chair back according to the occupants' personal preferences. This product is shown to deliver markedly better comfort at room temperatures well above typical office cooling setpoints. Experimental subjects reported satisfaction in these elevated air temperatures, partly because the chair's cooling effect was tuned to their own individual needs. Simulation of the chair in office buildings around the U.S. shows that energy can be saved everywhere, with impacts varying due to the climate. Total building HVAC energy savings exceeded 10% in hot-dry climate zones. Due to high product cost, simple payback for the chair we studied is beyond the expected chair life. We then understood the need to establish cost-performance targets for comfort delivery packages. NREL derived several hypothetical energy/cost/comfort targets for personal comfort product systems. In some climate regions around the U.S., these show the potential for office building HVAC energy savings in excess of 20%. This report documents this research, providing an overview of the research team's methods and results while also identifying areas for future research building upon the findings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Smart Homes and Buildings Research at the Energy Systems Integration Facility

Watch how NREL researchers are using the unique capabilities of the Energy Systems Integration Facility (ESIF) to develop technologies that will help the “smart” homes and buildings of the future perform efficiently and communicate effectively with the electricity grid while enhancing occupants' comfort and convenience.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Smart Power Lab at the Energy Systems Integration Facility

Watch how NREL researchers are using the Smart Power Laboratory at the Energy Systems Integration Facility (ESIF) to develop technologies that will help the "smart homes" of the future perform efficiently and communicate effectively with the electricity grid while enhancing occupants' comfort and convenience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electric Energy Management in the Smart Home: Perspectives on Enabling Technologies and Consumer Behavior

Smart homes hold the potential for increasing energy efficiency, decreasing costs of energy use, decreasing the carbon footprint by including renewable resources, and transforming the role of the occupant. At the crux of the smart home is an efficient electric energy management system that is enabled by emerging technologies in the electric grid and consumer electronics. This article presents a discussion of the state-of-the-art in electricity management in smart homes, the various enabling technologies that will accelerate this concept, and topics around consumer behavior with respect to energy usage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electric Energy Management in the Smart Home: Perspectives on Enabling Technologies and Consumer Behavior

Smart homes hold the potential for increasing energy efficiency, decreasing costs of energy use, decreasing the carbon footprint by including renewable resources, and trans-forming the role of the occupant. At the crux of the smart home is an efficient electric energy management system that is enabled by emerging technologies in the electricity grid and consumer electronics. This article presents a discussion of the state-of-the-art in electricity management in smart homes, the various enabling technologies that will accelerate this concept, and topics around consumer behavior with respect to energy usage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NILM Applications for the Energy-Efficient Home

We present a forecast for systems-focused applications of non-intrusive load monitoring (NILM), which meet the needs of homeowners, the technology sector, the service sector, and/or utilities. We discuss both near- and long-term applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technical Highlight: NREL Delivers In-Home HVAC Efficiency Testing Solutions (Fact Sheet)

Researchers at the National Renewable Energy Laboratory (NREL) have recently developed two simple in-home efficiency test methods that can be used by technicians, researchers, or interested homeowners to verify the correct operation and energy efficiency of a home's air conditioning equipment. An efficiency validation method for mini-split heat pumps (MSHPs) - highly efficient refrigerant-based air conditioning and heating systems that permit room-by-room conditioning and control - will enable building researchers to easily explore the installed performance of this class of equipment. MSHPs are very popular overseas and are gaining market share in energy efficient home upgrades throughout the United States. Yet, because MSHPs have multiple variable-speed components that work in tandem, their performance is challenging to measure in a real home. NREL researchers developed a field evaluation method including test equipment, methods, and data analysis to determine the installed performance of this equipment in occupied homes. A field test was conducted to validate the method. When testing a home's operation, it is often important to simulate occupancy within an unoccupied home. That way, the researcher will know the actual usage profiles for heat and moisture generation; this removes the uncertainty associated with real occupants. The second test method details a standardized protocol for generating heat and moisture loads, to mimic occupants and their activities by using heaters and humidifiers. Realistic heat and moisture loads can be used to drive air conditioning systems, evaluate air distribution systems, and examine building enclosure technologies. These loads are drawn from the Building America House Simulation Protocols. Proper application of the method will result in better comparison between performance of the test home and its simulated analogue. This method is also validated by field testing. These test methods are now available in two technical reports. The methods can be used widely by the building research community to confirm proper operation of space conditioning equipment in homes, thereby improving thermal comfort, building health, and durability. National objectives for cost-effective energy savings in the residential sector can be met more quickly and with greater consistency.

14 SOLAR ENERGY↗

Technical Highlight: NREL Delivers In-Home HVAC Efficiency Testing Solutions

Researchers at the National Renewable Energy Laboratory (NREL) have recently developed two simple in-home efficiency test methods that can be used by technicians, researchers, or interested homeowners to verify the correct operation and energy efficiency of a home’s air conditioning equipment.

heating, ventilation, air conditioning↗

Using EnergyPlus to Perform Dehumidification Analysis on Building America Homes

This study used EnergyPlus to investigate humidity issues on a typical mid-1990s reference home, a 2006 International Energy Conservation Code home, and a high-performance home in a hot-humid climate; the study confirmed that supplemental dehumidification should be provided to maintain space relative humidity below 60% in a hot-humid climate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Monitoring Protocol: Mini-Split Heat Pumps

This Building America program report provides a detailed method for accurately measuring and monitoring performance of a residential mini-split heat pump, which will be used in high-performance retrofit applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗