Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) Onboard Calibration System

The AVIRIS instrument uses an onboard calibration system to provide auxiliary calibration data. The system consists of tungsten halogen cycle lamp imaged onto a fiber bundle through an eight position filter wheel. The fiber bundle illuminates the back side of the foreoptics shutter during a pre-run and post-run calibration sequence. The filter wheel contains 2 neutral density filters, 5 spectral filters and blocked position.

spectrometer

Improvements to the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) Calibration System

As a continuing effort to increase the calibration accuracy of the AVIRIS data a number of recent improvements have been implemented and are in the process of being tested during the 1994 flight season. These include the following innovations: A direct observation of a laboratory radiance standard is now used to double check the wide field-of-view calibration via an integrating sphere source. Launch site field calibration of the AVIRIS sensor is now being planned to augment the laboratory and inflight calibration. Modification to a dry air conditioning unit has been made to enable ground calibration at flight operating temperatures. One hundred lines of dark imagery has been added to the end of each flight line to assist in the analysis and removal of residual coherent noise. The intensity of the onboard calibration lamp has been modified to improve response in the blue end of the spectrum. Novel spectral filters have been installed in the onboard calibration source.

Airborne Visible/Infrared Imaging Spectrometer Cal

Imaging Spectrometry-Concepts and System Tradeoffs

The concept of imaging spectrometry is finding broad application in scientific instrumentation for earth-based, airborne, and space applications. An imaging spectrometer is characterized by the combination of imaging with complete sampling in the spectral domain. In so doing, material identification can be accomplished and displayed in conjunction with the conventional recognizable image. An image spectrometer incorporates a wide variety of techniques, including focal plane arrays, imaging and spectrometer optics, and spectral dispersing devices. The design of a successful system involves a complex set of tradeoffs incorporating the properties and limitations of the various technologies. For applications in the infrared, additional technologies such as focal plane cooling are required, and the other technologies present more limitations and constraints.

Herring, M.

AVIRIS foreoptics, fiber optics and on-board calibrator

The foreoptics, fiber optic system and calibration source of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) are described. The foreoptics, based on a modified Kennedy scanner, is coupled by optical fibers to the four spectrometers. The optical fibers allow convenient positioning of the spectrometers in the limited space and enable simple compensation of the scanner's thermal defocus (at the -23 C operating temp) by active control of the fiber focal plane position. A challenging requirement for the fiber optic system was the transmission to the spectral range 1.85 to 2.45 microns at .45 numerical aperture. This was solved with custom fluoride glass fibers from Verre Fluore. The onboard calibration source is also coupled to the spectrometers by the fibers and provides two radiometric levels and a reference spectrum to check the spectrometers' alignment. Results of the performance of the assembled subsystems are presented.

Chrisp, M. P.