Engineering Papers⌕ Search

Engineering topics

Choi, Y

Publications and source records attributed to Choi, Y.

At least 19 records

Hybridized kagome bands and induced Ti magnetism in RTi3Bi4 (R = Nd, Sm, Gd) kagome metals studied using angle-resolved photoemission spectroscopy and x-ray magnetic circular dichroism

Kagome materials are known for hosting emergent quantum phenomena driven by the interaction between different lattice, charge and spin orders. Here, we present a detailed angle resolved photoemission (ARPES), density functional theory (DFT) and x-ray magnetic circular dichroism (XMCD) study of the electronic and magnetic structure of RTi3Bi4 (R = Nd, Sm, Gd). ARPES and DFT demonstrate that the bulk electronic band structure is dominated by the hybridization of the Ti bands, and the weak electron-like pocket at Γ is identified as a surface state. The isotropic XAS profile of the M 4,5-edge of the rare earth is consistent with the presence of R 3+ oxidation state. Using the XMCD sum rules, backed by the atomic multiplet theory calculations, we obtain the spin and orbital magnetic moments. The Ti L2,3-edge XMCD reveals the presence of a small magnetic moment in GdTi3Bi4, presumably driven by the proximity of the Ti kagome layers to the zigzag chains of Gd, while the total magnetic moment of Gd is shared by the f and d electrons. Our combined XMCD, ARPES and DFT study brings an important piece of information to understand the spin flip transitions and anomalous Hall effect observed in the RTi3Bi4 kagome metals.

Lim, C.↗

SU-F-T-460: Dosimetric Matching Between Trilogy Tx and TrueBeam STx

Purpose: To compare the commissioned beam data for one flattening filter photon mode (6 MV) and two flattening filter-free (FFF) photon modes (6 and 10 MV-FFF) between Trilogy Tx and TrueBeam STx and evaluate the possibility of dosimetric matching Methods: Dosimetric characteristics of the new Trilogy Tx including percent depth doses (PDDs), profiles, and output factors were measured for commissioning. Linear diode array detector and ion chambers were used to measure dosimetric data. The depth of dose maximum (dmax) and PDD at 10 cm (PDD10) were evaluated: 3×3 cm{sup 2}, 10×10 cm{sup 2}, and 40×40 cm{sup 2}. The beam profiles were compared and then penumbras were evaluated. As a further test of the dosimetric matching, the same VMAT plans were delivered, measured with film, and compared with TPS calculation. Results: All the measured PDDs matched well across the two units. PDD10 showed less than 0.5% variation and dmax were within 1.5 mm at the field sizes evaluated. Within the central 80% of transverse axis, profile data were almost identical. TrueBeam data resulted in a slightly greater penumbra width (up to 1.9 mm). The greatest differences of output factors were found at 40 × 40 cm{sup 2}: 2.40%, 2.03%, and 2.22% for 6 MV, 6 MV-FFF, and 10 MV-FFF, respectively. For smaller field sizes, less than 1% differences were observed. The film measurements demonstrated over 97.3% pixels passing-gamma analysis (2%/2mm). The results showed excellent agreement between measurements of two machines. Conclusion: The differences between Trilogy Tx and TrueBeam STx found could possibly affect small field and also very large field sizes in dosimetric matching considerations. These differences encountered are mostly related with the changes in the head design of the TrueBeam. Although it cannot guarantee full interchangeability of two machines, dosimetric matching by field size of 25 × 25 cm{sup 2} might be clinically acceptable.

07 ISOTOPE AND RADIATION SOURCES↗

Measurement of the decay B → D ℓ ν ℓ in fully reconstructed events and determination of the Cabibbo-Kobayashi-Maskawa matrix element | V c b |

We present a determination of the magnitude of the Cabibbo-Kobayashi-Maskawa matrix element |Vcb| using the decay B → Dℓν ℓ (ℓ = e,μ) based on 711 fb –1 of e + e – → Υ(4S) data recorded by the Belle detector and containing 772 × 10 6 BB¯ pairs. Here, one B meson in the event is fully reconstructed in a hadronic decay mode, while the other, on the signal side, is partially reconstructed from a charged lepton and either a D + or D 0 meson in a total of 23 hadronic decay modes. The isospin-averaged branching fraction of the decay B → Dℓν ℓ is found to be B(B 0 → D – ℓ + ν ℓ ) = (2.31 ± 0.03(stat) ± 0.11(syst))%. Analyzing the differential decay rate as a function of the hadronic recoil with the parametrization of Caprini, Lellouch, and Neubert and using the form-factor prediction G(1) = 1.0541 ± 0.0083 calculated by FNAL/MILC, we obtain η EW |V cb | = (40.12 ± 1.34) × 10 –3 , where ηEW is the electroweak correction factor. Alternatively, assuming the model-independent form-factor parametrization of Boyd, Grinstein, and Lebed and using lattice QCD data from the FNAL/MILC and HPQCD collaborations, we find η EW |V cb | = (41.10 ± 1.14) × 10 –3 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First observation of the decay B 0 → ψ ( 2 S ) π 0

We report a measurement of the B 0 → ψ(2S)π 0 branching fraction based on the full Υ(4S) data set of 772 × 10 6 BB¯ pairs collected by the Belle detector at the KEKB asymmetric-energy e + e – collider. We obtain B(B 0 → ψ(2S)π 0 ) = (1.17 ± 0.17(stat) ± 0.08(syst)) × 10 –5 . Here, the result has a significance of 7.2 standard deviations and is the first observation of the decay B 0 → ψ(2S)π 0 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evidence for the decay B 0 → η π 0

In this work, we report a search for the charmless hadronic decay B 0 → η π 0 with a data sample corresponding to an integrated luminosity of 694 fb - 1 containing 753 × 1 0 6 B B ¯ pairs. The data were collected by the Belle experiment running on the Υ ( 4 S ) resonance at the KEKB e + e - collider. We measure a branching fraction B ( B 0 → η π 0 ) = ( 4. 1 - 1.5 - 0.7 + 1.7 + 0.5 ) × 1 0 - 7 , where the first uncertainty is statistical and the second is systematic. Our measurement gives an upper limit of B ( B 0 → η π 0 ) < 6.5 × 1 0 - 7 at 90% confidence level. Finally, the signal has a significance of 3.0 standard deviations and constitutes the first evidence for this decay mode.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-D-201-02: Prediction of Delivered Dose Based On a Joint Histogram of CT and FDG PET Images

Purpose: To investigate whether pre-treatment images can be used in predicting microsphere distribution in tumors. When intra-arterial radioembolization using Y90 microspheres was performed, the microspheres were often delivered non-uniformly within the tumor, which could lead to an inefficient therapy. Therefore, it is important to estimate the distribution of microspheres. Methods: Early arterial phase CT and FDG PET images were acquired for patients with primary liver cancer prior to radioembolization (RE) using Y90 microspheres. Tumor volume was delineated on CT images and fused with FDG PET images. From each voxel (3.9×3.9×3.3 mm3) in the tumor, the Hounsfield unit (HU) from the CT and SUV values from the FDG PET were harvested. We binned both HU and SUV into 11 bins and then calculated a normalized joint-histogram in an 11×11 array.Patients also underwent a post-treatment Y90 PET imaging. Radiation dose for the tumor was estimated using convolution of the Y90 distribution with a dose-point kernel. We also calculated a fraction of the tumor volume that received a radiation dose great than 100Gy. Results: Averaged over 40 patients, 55% of tumor volume received a dose greater than 100Gy (range : 1.1 – 100%). The width of the joint histogram was narrower for patients with a high dose. For patients with a low dose, the width was wider and a larger fraction of tumor volume had low HU. Conclusion: We have shown the pattern of joint histogram of the HU and SUV depends on delivered dose. The patterns can predict the efficacy of uniform intra-arterial delivery of Y90 microspheres.

60 APPLIED LIFE SCIENCES↗

Measurement of the direct CP asymmetry in B¯->Xs+dy decays with a lepton tag

We report the measurement of the direct CP asymmetry in the radiative B¯?Xs+d? decay using a data sample of (772±11)×106 BB¯ pairs collected at the ?(4S) resonance with the Belle detector at the KEKB asymmetric-energy e+e- collider. The CP asymmetry is measured as a function of the photon energy threshold. For E*?=2.1 GeV, where E*? is the photon energy in the center-of-mass frame, we obtain ACP(B¯?Xs+d?)=(2.2±3.9±0.9)%, consistent with the Standard Model prediction.

Pesantez, L↗

Observation of X ( 3872 ) in B → X ( 3872 ) K π decays

We report the first observation of B 0 →X(3872)(K + π – ) and evidence for B + → X(3872)(K 0 π + ). We measure the product of branching fractions for the former to be B(B 0 → X(3872)(K + π – )) × B(X(3872) → J/ψπ + π – ) = (7.9 ± 1.3(stat) ± 0.4(syst)) × 10 –6 and find that B 0 → X(3872)K*(892) 0 does not dominate the B 0 → X(3872)K + π – decay mode. We also measure B(B + → X(3872)(K 0 π + )) × B(X(3872) → J/ψπ + π – ) = (10.6 ± 3.0(stat) ± 0.9(syst)) × 10 –6 . Furthermore, this study is based on the full data sample of 711 fb –1 (772 × 10 6 BB¯ pairs) collected at the Υ(4S) resonance with the Belle detector at the KEKB collider.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-T-269: Quality Assurance of Spine Volumetric Modulated Arc Therapy with Flattening Filter Free Beams Using Gafchromic EBT3 Films

Purpose: We implemented the Gafchromic film-based patient specific QA of volumetric modulated arc therapy (VMAT) with flattening-filter free (FFF) beams for spine metastases and validated the accuracy of fast arc delivery. Methods: EBT3 films and a homemade cylindrical QA phantom were employed for dosimetric verification of VMATs. For 14 FFF VMAT plans (10 with 10-MV FFF beams and 4 with 6-MV FFF beams), the doses were recalculated on the phantom and delivered by a TrueBeam STx accelerator equipped with a high-definition 120 leaf MLC. The EBT3 films were scanned using an Epson 10000XL scanner through the FilmQA Pro software. All the irradiated film images were converted to dose map using a calibration response curve. The resulting dose map of film measurement was compared with treatment plan and evaluated using gamma analysis with dose tolerance of 2% within 2 mm. In addition, the point-dose measurement in the phantom using an ion chamber was evaluated as a reference in a ratio of measured and planned doses. Results: The gamma pass rates averaged over all FFF plans for composite-field measurements were 96.0 ± 3.6% (88.9%–99.5%). When adopting a tolerance level of 3% - 3 mm, the gamma pass rates were improved with the ranges from 98% to 100%. In addition, dose profiles and dose distributions showed that spinal cord was protected by the rapid dose fall-off and by delivering the treatment with high precision. In point-dose measurements, the average differences between the measured and planned doses were 0.5% ± 1.0% of the prescription dose. Conclusion: We demonstrated that Gafchromic EBT3 film would be an effective patient-specific QA tool, especially for VMAT of spine SBRT with treatment of small fields and highly gradient dose distributions. The results of film QA verified that the dosimetric accuracy of spine SBRT utilizing RapidArc with FFF beams in our institution is reliable.

60 APPLIED LIFE SCIENCES↗