Engineering Papers⌕ Search

Engineering topics

Cheng, W

Publications and source records attributed to Cheng, W.

Mechanism for Selectivity-inactivation Coupling in KcsA Potassium Channels

Structures of the prokaryotic K{sup +} channel, KcsA, highlight the role of the selectivity filter carbonyls from the GYG signature sequence in determining a highly selective pore, but channels displaying this sequence vary widely in their cation selectivity. Furthermore, variable selectivity can be found within the same channel during a process called C-type inactivation. We investigated the mechanism for changes in selectivity associated with inactivation in a model K{sup +} channel, KcsA. We found that E71A, a noninactivating KcsA mutant in which a hydrogen-bond behind the selectivity filter is disrupted, also displays decreased K{sup +} selectivity. In E71A channels, Na{sup +} permeates at higher rates as seen with {sup 86}Rb{sup +} and {sup 22}Na{sup +} flux measurements and analysis of intracellular Na{sup +} block. Crystal structures of E71A reveal that the selectivity filter no longer assumes the 'collapsed,' presumed inactivated, conformation in low K{sup +}, but a 'flipped' conformation, that is also observed in high K{sup +}, high Na{sup +}, and even Na{sup +} only conditions. The data reveal the importance of the E71-D80 interaction in both favoring inactivation and maintaining high K{sup +} selectivity. We propose a molecular mechanism by which inactivation and K{sup +} selectivity are linked, a mechanism that may also be at work in other channels containing the canonical GYG signature sequence.

60 APPLIED LIFE SCIENCES↗

Simulation for the assessment of wall thinning using eddy current method

A pipe with protective cladding and insulation was simplified to a four-layered structure when the diameter of a pipe is large enough, and analytical solutions for sinusoidal and pulsed wave excitation were derived. Simulation implemented by using the analytical solutions showed that sinusoidal excitation is not appropriate for the monitoring of inner thinning, while pulsed eddy current method can be used to measure wall-thickness regardless of inner or outer thinning by using the decay rate of log(Bz) as a particular parameter to evaluate wall thickness.

42 ENGINEERING↗

DESIGN OF VISIBLE DIAGNOSTIC BEAMLINE FOR NSLS2 STORAGE RING

A visible synchrotron light monitor (SLM) beam line has been designed at the NSLS2 storage ring, using the bending magnet radiation. A retractable thin absorber will be placed in front of the first mirror to block the central x-rays. The first mirror will reflect the visible light through a vacuum window. The light is guided by three 6-inch diameter mirrors into the experiment hutch. In this paper, we will describe design work on various optical components in the beamline. The ultra high brightness NSLS-II storage ring is under construction at Brookhaven National Laboratory. It will have 3GeV, 500mA electron beam circulating in the 792m ring, with very low emittance (0.9nm.rad horizontal and 8pm.rad vertical). The ring is composed of 30 DBA cells with 15 fold symmetry. Three damping wigglers will be installed in long straight sections 8, 18 and 28 to lower the emittance. While electrons pass through the bending magnet, synchrotron radiation will be generated covering a wide spectrum. There are other insertion devices in the storage ring which will generate shorter wavelength radiation as well. Synchrotron radiation has been widely used as diagnostic tool to measure the transverse and longitudinal profile. Three synchrotron light beam lines dedicated for diagnostics are under design and construction for the NSLS-II storage ring: two x-ray beam lines (pinhole and CRL) with the source points from Cell 22 BM{_}A (first bending in the DBA cell) and Cell22 three-pole wiggler; the third beam line is using visible part of radiation from Cell 30 BM{_}B (second bending magnet from the cell). Our paper focuses on the design of the visible beam line - SLM.

43 PARTICLE ACCELERATORS↗

STRIPLINE KICKER DESIGN FOR NSLS2 STORAGE RING

In the NSLS2 storage ring, there are four stripline kickers/pickups. Two long striplines with electrode length of 30cm will be used as bunch-by-bunch transverse feedback actuators. Two short stripline kickers/pickups with 15cm length will mainly used for tune measurement excitation or signal pickup for the beam stability monitor. High shunt impedance of the long stripline kickers is demanded to produce 200 {micro}s damping time. Meanwhile the beam impedance should be minimized. The design work for these two types of stripline is discussed in this paper. NSLS2 is a third-generation light source under construction at Brookhaven National Laboratory. The machine will have < 1nm.rad horizontal emittance by using weak dipoles together with damping wigglers. For the storage ring of 792m circumference, geometric impedance, resistive wall impedance and ion effects are expected to be significant. A transverse bunch-by-bunch feedback system has been designed to suppress the coupled bunch instabilities. More information can be found in previous paper.

15cm length will mainly used for tune↗

High-Current Effects in The PEP-II Storage Rings

High beam currents in PEP-II have been a challenge for vacuum system and ring components. For the {approx} 1 cm long bunches peak currents exceed 100 A and modest impedance can give rise to voltage spikes and discharges. During the last two runs, difficulties arose from rf seals at the 'flex flanges' in the HER. High temperatures were seen and the seals turned out to be severely damaged by discharges. In the LER, the horizontal stripline kickers of the bunch-by-bunch feedback system experiences breakdown at high bunch current-Macor pins installed for mechanical stability turned out to be a weak spot causing discharges. Finally, in the HER an experiment to shorten the ion-clearing gap in the beam revealed signs of ion-induced instability indicating that the HER has been operating quite close to the stability limit. The effects shown here are relevant to future high-intensity electron and positron rings like SuperB and PEP-X.

43 PARTICLE ACCELERATORS↗

NSLS-II Beam Diagnostics Overview

A new 3rd generation light source (NSLS-II) is in the early stages of construction at Brookhaven National Laboratory. The NSLS-II facility will provide ultra high brightness and flux with exceptional beam stability. It presents several challenges for diagnostics and instrumentation, related to the extremely small emittance. In this paper, we present an overview of all planned instrumentation systems, results from research and development activities; and then focus on other challenging aspects.

43 PARTICLE ACCELERATORS↗

Suppression of 1/f Noise in Accumulation Mode FD-SOI MOSFETs on Si(100) and (110) Surfaces

In this paper, a new approach to reduce the 1/f noise levels in the MOSFETs on varied silicon orientations, such as Si(100) and (110) surfaces, has been carried out. We focus on the Accumulation-mode (AM) FD-SOI device structure and demonstrate that the 1/f noise levels in this AM FD-SOI MOSFETs are obviously reduced on both the Si(100) and (110) surfaces.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

PEP-II Status

PEP-II and BaBar have just finished run 7, the last run of the SLAC B-factory. PEP-II was one of the few high-current e+e- colliding accelerators and holds the present world record for stored electrons and stored positrons. It has stored 2.07 A of electrons, nearly 3 times the design current of 0.75 A and it has stored 3.21 A of positrons, 1.5 times more than the design current of 2.14 A. High-current beams require careful design of several systems. The feedback systems that control instabilities, the RF system stability loops, and especially the vacuum systems have to handle the higher power demands. We present here some of the accomplishments of the PEP-II accelerator and some of the problems we encountered while running high-current beams.

43 PARTICLE ACCELERATORS↗