Engineering PapersSearch

Engineering topics

Chen, Yue

Publications and source records attributed to Chen, Yue.

Bidding Curve Design for Hybrid Power Plants with Uncertain Solar Forecast

This paper presents a novel bidding curve design algorithm tailored for hybrid power plants (HPPs) to participate in the wholesale electricity market. Utilizing forecasts for photovoltaic (PV) generation and available battery power, our algorithm strategically computes the bidding curve to maximize HPP profit while adeptly managing the inherent uncertainty associated with PV power generation. In addition, the introduction of the penalty cost in HPP bidding curves provides the system operator a tool to effectively manage the system-level uncertainty that caused by HPPs. Numerical analysis through Monte Carlo simulations confirms that our bidding curve methodology outperforms the benchmark across various scenarios.

bidding curve

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid

Bidding Curve Design for Hybrid Power Plants with Uncertain Solar Forecast: Preprint

This paper presents a novel bidding curve design algorithm tailored for hybrid power plants (HPPs) to participate in the wholesale electricity market. Utilizing forecasts for photovoltaic (PV) generation and available battery power, our algorithm strategically computes the bidding curve to maximize HPP profit while adeptly managing the inherent uncertainty associated with PV power generation. In addition, the introduction of the penalty cost in HPP bidding curves provides the system operator a tool to effectively manage the system-level uncertainty that caused by HPPs. Numerical analysis through Monte Carlo simulations confirms that our bidding curve methodology outperforms the benchmark across various scenarios.

bidding curve

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids: Preprint

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid

PreMevE‐MEO: Predicting Ultra‐Relativistic Electrons Using Observations From GPS Satellites

Abstract Ultra‐relativistic electrons with energies greater than or equal to two megaelectron‐volt (MeV) pose a major radiation threat to spaceborne electronics, and thus specifying those highly energetic electrons has a significant meaning to space weather communities. Here we report the latest progress in developing our predictive model for MeV electrons in the outer radiation belt. The new version, primarily driven by electron measurements made along medium‐Earth‐orbits (MEO), is called PREdictive MEV Electron (PreMevE)‐MEO model that nowcasts ultra‐relativistic electron flux distributions across the whole outer belt. Model inputs include >2 MeV electron fluxes observed in MEOs by a fleet of GPS satellites as well as electrons measured by one Los Alamos satellite in the geosynchronous orbit. We developed an innovative Sparse Multi‐Inputs Latent Ensemble NETwork (SmileNet) which combines convolutional neural networks with transformers, and we used long‐term in situ electron data from NASA's Van Allen Probes mission to train, validate, optimize, and test the model. It is shown that PreMevE‐MEO can provide hourly nowcasts with high model performance efficiency and high correlation with observations. This prototype PreMevE‐MEO model demonstrates the feasibility of making high‐fidelity predictions driven by observations from longstanding space infrastructure in MEO, thus has great potential of growing into an invaluable space weather operational warning tool.

79 ASTRONOMY AND ASTROPHYSICS

Decentralized Microgrid Protection Through Relative Fault Direction Classification: Preprint

Protection in inverter-based resources (IBRs) dominated microgrids generally face significant challenges due to the low fault current and inconsistent fault behaviors from IBRs. Recently, machine learning-based approaches have attracted considerable attention to address these challenges. This paper introduces a novel decentralized protection strategy for microgrids. The proposed method decomposes the protection challenge into several distributed learning tasks, enabling individual relays to autonomously determine the direction of faults using a binary classification framework based on support vector machine (SVM) algorithms. Following the distributed fault direction estimation, classifier outcomes are shared among neighboring relays, facilitating a local decision-making process to ascertain the presence of faults within the neighborhood. Finally, a tripping signal is generated based on the classifier results of each relay to operate the circuit breaker. To test and validate this approach, a 100% renewable microgrid model is simulated in MATLAB/Simulink. In the numerical analysis, the application of SVM classifiers in our approach yields impressive results: an average relay classification accuracy of 98%, and a 96% accuracy in circuit breaker control. These findings highlight the potential of machine-learning-based approaches in enhancing the efficiency and reliability of microgrid protection systems.

decentralized algorithm

cheny-lanl/PreMevE-MEO-2024

This package contains R&D python codes that can nowcast >2 MeV electron distributions in the Earth's outer radiation belt, using LANL's GPS electron data (publicly available) as the primary driver. Functions of this PreMevE-MEO model has been described with details in a manuscript titled "PreMevE-MEO: Predicting Ultra-relativistic Electrons Using Observations from GPS Satellites" (LA-UR-24-23843), which has been submitted to Space Weather Journal.

Chen, Yue

Overview of recent experimental results on the EAST Tokamak

Since the last IAEA-FEC in 2021, significant progress on the development of long pulse steady state scenario and its related key physics and technologies have been achieved, including the reproducible 403 s long-pulse steady-state H-mode plasma with pure radio frequency (RF) power heating. A thousand-second time scale (~1056 s) fully non-inductive plasma with high injected energy up to 1.73 GJ has also been achieved. The EAST operational regime of high β P has been significantly extended (H 98y2 > 1.3, β P ~ 4.0, β N ~ 2.4 and n e /n GW ~ 1.0) using RF and neutral beam injection (NBI). The full edge localized mode suppression using the n = 4 resonant magnetic perturbations has been achieved in ITER-like standard type-I ELMy H-mode plasmas with q 95 ≈ 3.1 on EAST, extrapolating favorably to the ITER baseline scenario. The sustained large ELM control and stable partial detachment have been achieved with Ne seeding. The underlying physics of plasma-beta effect for error field penetration, where toroidal effect dominates, is disclosed by comparing the results in cylindrical theory and MARS-Q simulation in EAST. Breakdown and plasma initiation at low toroidal electric fields (<0.3 V m -1 ) with EC pre-ionization is developed. A beneficial role on the lower hybrid wave injection to control the tungsten concentration in the NBI discharge is observed for the first time in EAST suggesting a potential way toward steady-state H-mode NBI operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY