SU-F-T-52: Study of Energy Dependent Effect of Dosimetry Systems Used in Therapeutic Soft X-Ray Energy Range

Purpose: To investigate energy dependent effects of different dosimetry systems which can be used as in vivo dosimetry monitoring for intraoperative radiotherapy in therapeutic soft x-ray energy range. Methods: Three dosimetry systems were evaluated in therapeutic soft x-ray energy range: optically stimulated luminescent dosimeter (OSLD) nanoDots, radiochromic EBT2 and EBT3 films. The x-ray photons were produced by a Zeiss Intrabeam 50 kV x-ray radiotherapy system. Solid water and bolus slabs with different thicknesses were used in the process of irradiation. An aluminum filter set was used to measure HVLs of X-rays. Calibration curves were made at different depth of boluses. Results: Half Value Layers at depths of 0, 3, 10, and 20 mm of solid water were measured to represent the energy change versus depth, yielding 0.306, 0.482, 0.865 and 0.901 respectively and indicating nearly unchanged HVL beyond 1 cm depth. The responses of each system at different depths were normalized to the response at 2 cm depth. In film dosimetry, the response is calculated as optical density (OD). The results show that there is nearly the same energy dependence for EBT2 and EBT3. At a HVL of 0.482 mm Al, the relative responses of nanoDots and EBT3 are 0.85 ± 0.04 and 0.89 ± 0.03 compared to those at 0.901 mm Al HVL, respectively, indicating no obvious difference between those two systems within the measurement uncertainty. Conclusion: It was observed that the studied dosimeter response increases about 13% from the x-ray energy of 0.48 mm Al to 0.90 mm Al. Therefore, caution should be exercised in using an appropriate calibration curve, and x-ray beam hardening effect has to be taken into account.

60 APPLIED LIFE SCIENCES↗

SU-F-T-53: Treatment Planning with Inhomogeneity Correction for Intraoperative Radiotherapy Using KV X-Ray Beams

Purpose: The current standard in dose calculation for intraoperative radiotherapy (IORT) using the ZEISS Intrabeam 50 kV x-ray system is based on depth dose measurements in water and no heterogeneous tissue effect has been taken into account. We propose an algorithm for pre-treatment planning including inhomogeneity correction based on data of depth dose measurements in various tissue phantoms for kV x-rays. Methods: Direct depth dose measurements were made in air, water, inner bone and cortical bone phantoms for the Intrabeam 50 kV x-rays with a needle applicator. The data were modelled by a function of power law combining exponential with different parameters. Those phantom slabs used in the measurements were scanned to obtain CT numbers. The x-ray beam initiated from the source isocenter is ray-traced through tissues. The corresponding doses will be deposited/assigned at different depths. On the boundary of tissue/organ changes, the x-ray beam will be re-traced in new tissue/organ starting at an equivalent depth with the same dose. In principle, a volumetric dose distribution can be generated if enough directional beams are traced. In practice, a several typical rays traced may be adequate in providing estimates of maximum dose to the organ at risk and minimum dose in the target volume. Results: Depth dose measurements and modeling are shown in Figure 1. The dose versus CT number is shown in Figure 2. A computer program has been written for Kypho-IORT planning using those data. A direct measurement through 2 mm solid water, 2 mm inner bone, and 1 mm solid water yields a dose rate of 7.7 Gy/min. Our calculation shows 8.1±0.4 Gy/min, consistent with the measurement within 5%. Conclusion: The proposed method can be used to more accurately calculate the dose by taking into account the heterogeneous effect. The further validation includes comparison with Monte Carlo simulation.

60 APPLIED LIFE SCIENCES↗

SU-F-T-58: Dosimetric Evaluation of Breast Tissue Composition for Electronic Brachytherapy (BET) Source In High Dose Rate Accelerated Partial Breast (APBI) Irradiation

Purpose: To quantitatively evaluate the dosimetric impact of differing breast tissue compositions for electronic brachytherapy source for high dose rate accelerated partial breast irradiation. Methods: A series of Monte Carlo Simulation were created using the GEANT4 toolkit (version 10.0). The breast phantom was modeled as a semi-circle with a radius of 5.0 cm. A water balloon with a radius of 1.5 cm was located in the phantom with the Xoft AxxentTM EBT source placed at center as a point source. A mixed of two tissue types (adipose and glandular tissue) was assigned as the materials for the breast phantom with different weight ratios. The proportionality of glandular and adipose tissue was simulated in four different fashions, 80/20, 70/30, 50/50 and 30/70 respectively. The custom energy spectrum for the 50 kVp XOFT source was provided via the manufacturer and used to generate incident photons. The dose distributions were recorded using a parallel three dimensional mesh with a size of 30 × 30 × 30 cm3 with 1 × 1 × 1 mm3 voxels. The simulated doses absorbed along the transverse axis were normalized at the distance of 1 cm and then compared with the calculations using standard TG-43 formalism. Results: All simulations showed underestimation of dose beyond balloon surface compared to standard TG-43 calculations. The maximum percentage differences within 2 cm distance from balloon surface were found to be 18%, 11%, 10% and 8% for the fat breast (30/70), standard breast (50/50), dense breast (70/30 and 80/20), respectively. Conclusion: The accuracy of dose calculations for low energy EBT source was limited when considering tissue heterogeneous composition. The impact of atomic number on photo-electric effect for lower energy Brachytherapy source is not accounted for and resulting in significant errors in dose calculation.

60 APPLIED LIFE SCIENCES↗

SU-F-T-143: Implementation of a Correction-Based Output Model for a Compact Passively Scattered Proton Therapy System

Purpose: To commission and investigate the accuracy of an output (cGy/MU) prediction model for a compact passively scattered proton therapy system. Methods: A previously published output prediction model (Sahoo et al, Med Phys, 35, 5088–5097, 2008) was commissioned for our Mevion S250 proton therapy system. This model is a correction-based model that multiplies correction factors (d/MUwnc=ROFxSOBPF xRSFxSOBPOCFxOCRxFSFxISF). These factors accounted for changes in output due to options (12 large, 5 deep, and 7 small), modulation width M, range R, off-center, off-axis, field-size, and off-isocenter. In this study, the model was modified to ROFxSOBPFxRSFxOCRxFSFxISF-OCFxGACF by merging SOBPOCF and ISF for simplicity and introducing a gantry angle correction factor (GACF). To commission the model, outputs over 1,000 data points were taken at the time of the system commissioning. The output was predicted by interpolation (1D for SOBPF, FSF, and GACF; 2D for RSF and OCR) with inverse-square calculation (ISF-OCR). The outputs of 273 combinations of R and M covering total 24 options were measured to test the model. To minimize fluence perturbation, scattered dose from range compensator and patient was not considered. The percent differences between the predicted (P) and measured (M) outputs were calculated to test the prediction accuracy ([P-M]/Mx100%). Results: GACF was required because of up to 3.5% output variation dependence on the gantry angle. A 2D interpolation was required for OCR because the dose distribution was not radially symmetric especially for the deep options. The average percent differences were −0.03±0.98% (mean±SD) and the differences of all the measurements fell within ±3%. Conclusion: It is concluded that the model can be clinically used for the compact passively scattered proton therapy system. However, great care should be taken when the field-size is less than 5×5 cm{sup 2} where a direct output measurement is required due to substantial output change by irregular block shape.

60 APPLIED LIFE SCIENCES↗

SU-F-T-146: Comparing Monte Carlo Simulations with Commissioning Beam Data for Mevion S250 Proton Therapy System

Purpose: To evaluate the Monte Carlo simulated beam data with the measured commissioning data for the Mevion S250 proton therapy system. Method: The Mevion S250 proton therapy system utilizes a passive double scattering technique with a unique gantry mounted superconducting accelerator and offers effective proton therapy in a compact design concept. The field shaping system (FSS) includes first scattering foil, range modulator wheel (RMW), second scattering foil and post absorber and offers two field sizes and a total of 24 treatment options from proton range of 5 cm to 32 cm. The treatment nozzle was modeled in detail using TOPAS (TOolkit for PArticle Simulation) Monte Carlo code. The timing feathers of the moving modulator wheels were also implemented to generate the Spread Out Bragg Peak (SOBP). The simulation results including pristine Bragg Peak, SOBP and dose profiles were compared with the data measured during beam commissioning. Results: The comparison between the measured data and the simulation data show excellent agreement. For pristine proton Bragg Peaks, the simulated proton range (depth of distal 90%) values agreed well with the measured range values within 1 mm accuracy. The differences of the distal falloffs (depth from distal 80% to 20%) were also found to be less than 1 mm between the simulations and measurements. For the SOBP, the widths of modulation (depth of proximal 95% to distal 90%) were also found to agree with the measurement within 1 mm. The flatness of the simulated and measured lateral profiles was found to be 0.6 % and 1.1 %, respectively. Conclusion: The agreement between simulations and measurements demonstrate that TOPAS could be used as a viable platform to proton therapy applications. The matched simulation results offer a great tool and open opportunity for variety of applications.

60 APPLIED LIFE SCIENCES↗

SU-F-T-160: Commissioning of a Single-Room Double-Scattering Proton Therapy System

Purpose: To report the detailed commissioning experience for a compact double-scattering Mevion S250 proton therapy system at a University Cancer Center site. Methods: The commissioning of the proton therapy system mainly consisted of ensuring integrity of mechanical and imaging system, beam data collection, and commissioning of a treatment planning system (TPS). First, mechanical alignment and imaging were tested including safety, interlocks, positional accuracy of couch and gantry, image quality, mechanical and imaging isocenter and so on. Second, extensive beam data (outputs, PDDs, and profiles) were collected and analyzed through effective sampling of range (R) and modulation width (M) from 24 beam options. Three different output (cGy/MU) prediction models were also commissioned as primary and secondary MU calculation tool. Third, the Varian Eclipse TPS was commissioned through five sets of data collections (in-water Bragg peak scans, in-air longitudinal fluence scans, in-air lateral profiles, in-air half-beam profiles, and an HU-to-stopping-power conversion curve) and accuracy of TPS calculation was tested using in-water scans and dose measurements with a 2D array detector with block and range compensator. Finally, an anthropomorphic phantom was scanned and heterogeneity effects were tested by inserting radiochromic films in the phantom and PET activation scans for range verification in conjunction with end-to-end test. Results: Beam characteristics agreed well with the vendor specifications; however, minor mismatches in R and M were found in some measurements during the beam data collection. These were reflected into the TPS commissioning such that the TPS could accurately predict the R and M within tolerance levels. The output models had a good agreement with measured outputs (<3% error). The end-to-end test using the film and PET showed reasonably the TPS predicted dose, R and M in heterogeneous medium. Conclusion: The proton therapy system was successfully commissioned and was released for clinical use.

60 APPLIED LIFE SCIENCES↗

SU-F-T-171: Manufacturing Cost Effective Heterogeneous Phantoms for Use in Proton Therapy

Purpose: To study the feasibility of 3D printing cost effective heterogeneous phantoms for use in proton therapy treatment planning quality assurance. Methods: A desktop 3D printer was utilized to create a series of 2 cm × 2 cm × 4 cm PLA plastic blocks of varying fill materials and hexagonal fill pattern. The blocks were than tested when filled with air, polyurethane foam, paraffin, silicone, and caulk of calcium carbonate – acrylic polymer blend. The blocks were evaluated with a “GE Lightspeed” 16 slice CT scanner and average CT# of the materials’ centers evaluated. Blocks were then placed into a custom aperture fitted to a Mevion Proton system to determine the relative stopping power of each. Scans were performed in water tank with Marcus type parallel plate chamber under a beam with a range of 15 cm and modulation of 2 cm. Shifts in range occurring relative to the 80% distal edge of the open SOBP were evaluated. Results: The CT#s of the blocks were plotted against their measured relative stopping power. This curve was compared to that which is in clinical use. While the trend agrees generally, specific differences between the relative stopping powers were as great as 10%. Conclusion: We have demonstrated that it is possible to utilize different cost effective materials in the manufacturing of phantoms for use in proton therapy. While different materials may provide better agreement to established calibration curves, a custom curve specific to the materials used may be utilized to accurately predict proton treatment dose distributions.

60 APPLIED LIFE SCIENCES↗

SU-F-T-323: A Post-Mastectomy Radiation Therapy Dose Distribution Study Using Nanodots and Films

Purpose: In post-mastectomy radiation therapy (RT), skin dose must be accurately estimated to assess skin reactions such as erythema, desquamation and necrosis. Planning systems cannot always provide accurate dosimetry for target volumes distal to skin. Therefore, in-vivo dosimetry is necessary. A female anthropomorphic phantom was used with optically stimulated luminescence dosimeters (nanoDots) to measure dose to chest wall skin. In addition, EBT2 films was employed to measure dose to left lung and heart in post-mastectomy RT. Methods: Films and nanoDots were calibrated under full buildup conditions at 100cm SAD for 6MV photons. Five pieces of films were placed between slabs of Rando phantom to assess dose to left lung and heart. Two layers of 0.5cm thick bolus were used to cover the whole left chest. Six pairs of nanoDots were placed at medical and lateral aspects on the bolus surface, between the 0.5cm bolus layers, and under the bolus. Three control nanoDots were placed on chest wall to quantify imaging dose. The phantom was CT scanned with all dosimeters in place, and treatment planning was performed with tangential fields (200cGy). All dosimeters were contoured on CT and dose was extracted. NanoDots were read using nanoDot reader and films were scanned using film scanner. The measured and calculated doses were tabulated. Results: Dose to 12 nanoDots were evaluated. Dose variance for surface nanoDots were +3.8%, +2.7%, −5% and −9.8%. Those at lateral positions, with greater beam obliquity had larger variance than the medial positions. A similar trend was observed for other nanoDots (Table1). Point doses from films for heart and the left lung were 112.7cGy and 108.7cGy, with +10.2% and +9.04% deviation from calculated values, respectively. Conclusion: Dosimetry provided by the advanced planning system was verified using NanoDots and films. Both nanoDots and films provided good estimation of dose distribution in post-mastectomy RT.

60 APPLIED LIFE SCIENCES↗

SU-F-T-359: Incorporating Dose Volume Histogram Prediction Into Auto-Planning for Volumetric-Modulated Arc Therapy in Rectal Cancer

Purpose: To incorporate dose volume histogram (DVH) prediction into Auto-Planning for volumetric-modulated arc therapy (VMAT) treatment planning and investigate the benefit of this new technique for rectal cancer. Methods: Ninety clinically accepted VMAT plans for patients with rectal cancer were selected and trained in the RapidPlan for DVH prediction. Both internal and external validations were performed before implementing the prediction model. A new VMAT planning method (hybrid-VMAT) was created with combining the DVH prediction and Auto-Planning. For each new patient, the DVH will be predicted and individual DVH constrains will be obtained and were exported as the original optimization parameters to the Auto-Planning (Pinnacle3 treatment planning system, v9.10) for planning. A total of 20 rectal cancer patients previously treated with manual VMAT (manual-VMAT) plans were replanned using this new method. Dosimetric comparisons were performed between manual VMAT and new method plans. Results: Hybrid-VMAT shows similar PTV coverage to manual-VMAT in D2%, D98% and HI (p>0.05) and superior coverage in CI (p=0.000). For the bladder, the means of V40 and mean dose are 36.0% and 35.6Gy for hybrid-VMAT and 42% and 38.0Gy for the manual-VMAT. For the left (right) femur, the means of V30 and mean dose are 10.6% (11.6%) and 17.9Gy (19.2Gy) for the hybrid-VMAT and 25.6% (24.1%) and 27.3Gy (26.2Gy) for the manual-VMAT. The hybrid-VMAT has significantly improved the organs at risk sparing. Conclusion: The integration of DVH prediction and Auto-Planning significantly improve the VMAT plan quality in the rectal cancer radiotherapy. Our results show the benefit of the new method and will be further investigated in other tumor sites.

60 APPLIED LIFE SCIENCES↗

SU-F-T-654: Pacemaker Dose Estimate Using Optically Stimulated Luminescent Dosimeter for Left Breast Intraoperative Radiation Therapy

Purpose: To assess and report the in vivo dose for a patient with a pacemaker being treated in left breast intraoperative radiation therapy (IORT). The ZEISS Intrabeam 50 kVp X-ray beam with a spherical applicator was used. Methods: The optically stimulated luminescent dosimeters (OSLDs) (Landauer nanoDots) were employed and calibrated under the conditions of the Intrabeam 50 kVp X-rays. The nanoDots were placed on the patient at approximately 15 cm away from the lumpectomy cavity both under and above a shield of lead equivalence 0.25 mm (RayShield X-Drape D-110) covering the pacemaker area during IORT with a 5 cm spherical applicator. Results: The skin surface dose near the pacemaker during the IORT with a prescription of 20 Gy was measured as 4.0±0.8 cGy. The dose behind the shield was 0.06±0.01 Gy, demonstrating more than 98% dose reduction. The in vivo skin surface doses during a typical breast IORT at a 4.5 cm spherical applicator surface were further measured at 5, 10, 15, and 20 cm away to be 159±11 cGy, 15±1 cGy, 6.6±0.5 cGy, and 1.8±0.1 cGy, respectively. A power law fit to the dose versus the distance z from the applicator surface yields the dose fall off at the skin surface following z^-2.5, which can be used to estimate skin doses in future cases. The comparison to an extrapolation of depth dose in water reveals an underestimate of far field dose using the manufactory provided data. Conclusion: The study suggests the appropriateness of OSLD as an in vivo skin dosimeter in IORT using the Intrabeam system in a wide dose range. The pacemaker dose measured during the left breast IORT was within a safe limit.

60 APPLIED LIFE SCIENCES↗

TU-FG-BRB-08: Challenges, Limitations and Future Outlook Towards Clinical Translation of Proton Acoustic Range Verification

Purpose: To report our investigations of proton acoustic imaging, including computer simulations and preliminary experimental studies at clinical facilities. The ultimate achievable accuracy, sensitivity and clinical translation challenges are discussed. Methods: The acoustic pulse due to pressure rise was estimated using finite element model. Since the ionoacoustic pulse is highly dependent on the proton pulse width and energy, multiple pulse widths were studied. Based on the received signal spectrum at piezoelectric ultrasound transducer with consideration of random thermal noise, maximum spatial resolution of the proton-acoustic imaging modality was calculated. The simulation studies defined the design specifications of the system to detect proton acoustic signal from Hitachi and Mevion clinical machines. A 500 KHz hydrophone with 100 dB amplification was set up in a water tank placed in front of the proton nozzle A 40 MHz data acquisition was synchronized by a trigger signal provided by the machine. Results: Given 30–800 mGy dose per pulse at the Bragg peak, the minimum number of protons detectable by the proton acoustic technique was on the order of 10×10^6 per pulse. The broader pulse widths produce signal with lower acoustic frequencies, with 10 µs pulses producing signals with frequency less than 100 kHz. As the proton beam pulse width increases, a higher dose rate is required to measure the acoustic signal. Conclusion: We have established the minimal detection limit for protonacoustic range validation for a variety of pulse parameters. Our study indicated practical proton-acoustic range verification can be feasible with a pulse shorter than 10 µs, 5×10^6 protons/pulse, 50 nA beam current and a highly sensitive ultrasonic transducer. The translational challenges into current clinical machines include proper magnetic shielding of the measurement equipment, providing a clean trigger signal from the proton machine, providing a shorter proton beam pulse and higher dose per pulse.

60 APPLIED LIFE SCIENCES↗

WE-AB-207A-12: HLCC Based Quantitative Evaluation Method of Image Artifact in Dental CBCT

Purpose: Image artifacts are usually evaluated qualitatively via visual observation of the reconstructed images, which is susceptible to subjective factors due to the lack of an objective evaluation criterion. In this work, we propose a Helgason-Ludwig consistency condition (HLCC) based evaluation method to quantify the severity level of different image artifacts in dental CBCT. Methods: Our evaluation method consists of four step: 1) Acquire Cone beam CT(CBCT) projection; 2) Convert 3D CBCT projection to fan-beam projection by extracting its central plane projection; 3) Convert fan-beam projection to parallel-beam projection utilizing sinogram-based rebinning algorithm or detail-based rebinning algorithm; 4) Obtain HLCC profile by integrating parallel-beam projection per view and calculate wave percentage and variance of the HLCC profile, which can be used to describe the severity level of image artifacts. Results: Several sets of dental CBCT projections containing only one type of artifact (i.e. geometry, scatter, beam hardening, lag and noise artifact), were simulated using gDRR, a GPU tool developed for efficient, accurate, and realistic simulation of CBCT Projections. These simulated CBCT projections were used to test our proposed method. HLCC profile wave percentage and variance induced by geometry distortion are about 3∼21 times and 16∼393 times as large as that of the artifact-free projection, respectively. The increase factor of wave percentage and variance are 6 and133 times for beam hardening, 19 and 1184 times for scatter, and 4 and16 times for lag artifacts, respectively. In contrast, for noisy projection the wave percentage, variance and inconsistency level are almost the same with those of the noise-free one. Conclusion: We have proposed a quantitative evaluation method of image artifact based on HLCC theory. According to our simulation results, the severity of different artifact types is found to be in a following order: Scatter>Geometry>Beam hardening>Lag>Noise>Artifact-free in dental CBCT.

60 APPLIED LIFE SCIENCES↗

TH-AB-209-08: Next Generation Dedicated 3D Breast Imaging with XACT

Purpose: Exposure to radiation increases the risk of cancer. We have designed a new imaging paradigm, X-ray induced acoustic computed tomography (XACT). Applying this innovative technology to breast imaging, an X-ray exposure can generate a 3D acoustic image, which dramatically reduces the radiation dose to patients when compared to conventional breast CT. Methods: Theoretical calculations are done to determine the appropriate X-ray energy and ultrasound frequency in breast XACT imaging. A series of breast CT image along the coronal plane from a patient with calcifications in the breast tissue are used as the source image. HU value based segmentation is done to distinguish the skin, adipose tissue, glandular tissue, breast calcification, and chest bone from each CT image. X-ray dose deposition in each pixel is calculated based on the tissue type by using GEANT4 Monte Carlo toolkits. The initial pressure rise caused by X-ray energy deposition is calculated according to tissue properties. Then, the X-ray induced acoustic wave propagation is simulated by K-WAVE toolkit. Breast XACT images are reconstructed from the recorded time-dependent ultrasound waves. Results: For imaging a breast with large size (16cm in diameter at chest wall), the photon energy of X-ray source and the central frequency of ultrasound detector is determined as 20keV and 5.5MHz. Approximately 10 times contrast between a calcification and the breast tissue can be acquire from XACT image. The calcification can be clearly identified from the reconstructed XACT image. Conclusion: XACT technique takes the advantages of X-ray absorption contrast and high ultrasonic resolution. With the proposed innovative technology, one can potentially reduce radiation dose to patient in 3D breast imaging as compared with current x-ray modalities, while still maintaining high imaging contrast and spatial resolution.

60 APPLIED LIFE SCIENCES↗

New Results from the Search for Low-Mass Weakly Interacting Massive Particles with the CDMS low ionization Threshold Experiment

The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic germanium detectors operated at a relatively high bias voltage to amplify the phonon signal in the search for weakly interacting massive particles (WIMPs). Results are presented from the second CDMSlite run with an exposure of 70 kg day, which reached an energy threshold for electron recoils as low as 56 eV. A fiducialization cut reduces backgrounds below those previously reported by CDMSlite.

New Results, Low-Mass, Mazzive Particles, CDMS Low↗

Effect of Vinylene Carbonate and Fluoroethylene Carbonate on SEI Formation on Graphitic Anodes in Li-Ion Batteries

Binder free (BF) graphite electrodes were utilized to investigate the effect of electrolyte additives fluoroethylene carbonate (FEC) and vinylene carbonate (VC) on the structure of the solid electrolyte interface (SEI). The structure of the SEI has been investigated via ex-situ surface analysis including X-ray Photoelectron spectroscopy (XPS), Hard XPS (HAXPES), Infrared spectroscopy (IR) and transmission electron microscopy (TEM). The components of the SEI have been further investigated via nuclear magnetic resonance (NMR) spectroscopy of D2O extractions. The SEI generated on the BF-graphite anode with a standard electrolyte (1.2 M LiPF6 in ethylene carbonate (EC) / ethyl methyl carbonate (EMC), 3/7 (v/v)) is composed primarily of lithium alkyl carbonates (LAC) and LiF. Incorporation of VC (3% wt) results in the generation of a thinner SEI composed of Li2CO3, poly(VC), LAC, and LiF. Incorporation of VC inhibits the generation of LAC and LiF. Incorporation of FEC (3% wt) also results in the generation of a thinner SEI composed of Li2CO3, poly(FEC), LAC, and LiF. The concentration of poly(FEC) is lower than the concentration of poly(VC) and the generation of LAC is inhibited in the presence of FEC. The SEI appears to be a homogeneous film for all electrolytes investigated.

25 ENERGY STORAGE↗

SU-E-I-85: Absorbed Dose Estimation for a Commercially Available MicroCT Scanner

Purpose: To quantify the simulated absorbed dose delivered for a typical scan from a commercially available microCT scanner in order to aid in the dose estimation. Methods: The simulations were conducted using the Geant4 Monte Carlo Toolkit (version 10) with the standard electromagnetic classes. The Quantum FX microCT scanner (PerkinElmer, Waltham, MA) was modeled incorporating the energy fluence and angular distributions of generated photons, spatial dimensions of nominal source-to-object and source-to-detector distances. The energy distribution was measured using a spectrometer (X-123CdTe, Amptek Inc., Bedford, USA) with a 300 angular spread from the source for the 90 kVp X-ray beams with no additional filtration. The nominal distances from the source to object consisted of three setups: 154.0 mm, 104.0 mm, and 51.96 mm. Our simulations recorded the dose absorbed in a cylindrical phantom of PMMA with a fixed length of 2 cm and varying radii (10, 20, 30 and 40 mm) using 100 million incident photons. The averaged absorbed dose in the object was then quantified for all setups. An exposure measurement of 417 mR was taken using a Radcal 9095 system utilizing 10×9–180 ion chamber with the given technique of 90 kVp, 63 μA, and 12 s. The exposure rate was also simulated with same setup to calculate the conversion factor of the beam current and the number of incident photons. Results: For a typical cone-beam scan with non-filtered 90kVp, the dose coefficients (the absorbed dose per mAs) were 2.614, 2.549 and 2.467 μGy/mAs under source to object distance of 104 mm for the object diameters of 10 mm, 20 mm and 30 mm, respectively. Conclusion: A look-up table was developed where an investigator can estimate the delivered dose using this particular microCT given the scanning protocol (kVp and mAs) as well as the size of the scanned object.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-133: Autosegmentation of Linac CBCT: Improved Accuracy Via Penalized Likelihood Reconstruction

Purpose: To improve the quality of kV X-ray cone beam CT (CBCT) for use in radiotherapy delivery assessment and re-planning by using penalized likelihood (PL) iterative reconstruction and auto-segmentation accuracy of the resulting CBCTs as an image quality metric. Methods: Present filtered backprojection (FBP) CBCT reconstructions can be improved upon by PL reconstruction with image formation models and appropriate regularization constraints. We use two constraints: 1) image smoothing via an edge preserving filter, and 2) a constraint minimizing the differences between the reconstruction and a registered prior image. Reconstructions of prostate therapy CBCTs were computed with constraint 1 alone and with both constraints. The prior images were planning CTs(pCT) deformable-registered to the FBP reconstructions. Anatomy segmentations were done using atlas-based auto-segmentation (Elekta ADMIRE). Results: We observed small but consistent improvements in the Dice similarity coefficients of PL reconstructions over the FBP results, and additional small improvements with the added prior image constraint. For a CBCT with anatomy very similar in appearance to the pCT, we observed these changes in the Dice metric: +2.9% (prostate), +8.6% (rectum), −1.9% (bladder). For a second CBCT with a very different rectum configuration, we observed +0.8% (prostate), +8.9% (rectum), −1.2% (bladder). For a third case with significant lateral truncation of the field of view, we observed: +0.8% (prostate), +8.9% (rectum), −1.2% (bladder). Adding the prior image constraint raised Dice measures by about 1%. Conclusion: Efficient and practical adaptive radiotherapy requires accurate deformable registration and accurate anatomy delineation. We show here small and consistent patterns of improved contour accuracy using PL iterative reconstruction compared with FBP reconstruction. However, the modest extent of these results and the pattern of differences across CBCT cases suggest that significant further development will be required to make CBCT useful to adaptive radiotherapy.

60 APPLIED LIFE SCIENCES↗

SU-E-T-303: Dosimetric Comparison of a LINAC Fallback Plan Generated From Tomotherapy System

Purpose: Quantitatively evaluate the Multi Criteria Optimization (MCO) based MLC step and shoot (sMLC) fallback plan derived from Tomotherapy of multiple lesions lung SBRT Methods: Inter-comparison of various IMRT planning systems tends to be difficult due to the vendor-specific functionalities. The methodology of defining dose constraints and beam geometries is challenging. Raysearch™ planning system offers an alternative replanning to deliver same intensity map from Tomotherapy without modifying original fluence. This intuitive comparison comes from the final fluence map converted without any embedded system dependent dose optimization. This planner independent approach could be utilized to study the merits of individual machines. The term “fallback” was utilized to (A) transfer plans in among treatment delivery systems; (B) maintain acceptable plan qualities; and (C) minimize the biological dose impact due to machine breakdown. The Tomotherapy specific DICOM RT dose and plan are retrieved into Raystation’s pre-defined sMLC protocol. Based on specific machine characteristics, same fluence maps were converted to generate equivalent deliverable segments. Therefore, the treatment plans were evaluated among two planning tools, Tomotherapy and MCO based sMLC delivery plans. Results: By converting the fluence map with the pre-defined machine characteristics, the 9-fields fallback plan has similar ITV coverage compared to the original Tomotherapy plan. ITV average doses, the D95 consisted of 0.9% variation. The total lung doses of fallback plan drifted from 17.4% to 30.5% which represents the limitations of the static beam delivery. D2 of fallback spinal cord increased from 22.4% to 36.4% but still within tolerances. Ipsilateral lung changed from 11.0% to 22.6%. Low dose region between ITVs presented increased dose to the normal lung tissues. Conclusion: Acceptable fallback plan for Tomotherapy SBRT has similar ITVs coverage, but lack of the normal tissues avoidance due to the limitation of geometrical factors to reduce doses in between ITVs.

60 APPLIED LIFE SCIENCES↗