Engineering Papers⌕ Search

Engineering topics

Chen, J.

Publications and source records attributed to Chen, J..

At least 199 records · Page 11

Investigation of the C 14 + α molecular configuration in O 18 by means of transfer and sequential decay reaction

A multinucleon transfer and cluster-decay experiment, namely 9 Be( 13 C, 18 O*→ 14 C+α)α, was performed at a beam energy of 65 MeV. Resonant states in 18O from 7 to 19 MeV, including some newly observed ones, are reconstructed with high resolution, based on the coincident detection of various combinations of the final fragments. Here, the α-decay branching ratios for 14 states are extracted from both the invariant-mass and the missing-mass measurements. Angular correlation analysis was conducted for the 10.3-MeV (4 + ) state. The present work supports the existence of the positive-parity rotational band associated with the 14 C+α molecular structure in 18 O, but the negative-parity band members were not identified.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SNEMO: Improved Empirical Models for Type Ia Supernovae

Type Ia supernova cosmology depends on the ability to fit and standardize observations of supernova magnitudes with an empirical model. We present here a series of new models of SN Ia spectral time series that capture a greater amount of supernova diversity than is possible with the models that are currently customary. These are entitled SuperNova Empirical MOdels (SNEMO; https://snfactory.lbl.gov/snemo). The models are constructed using spectrophotometric time series from 172 individual supernovae from the Nearby Supernova Factory, comprising more than 2000 spectra. Using the available observations, Gaussian processes are used to predict a full spectral time series for each supernova. A matrix is constructed from the spectral time series of all the supernovae, and Expectation Maximization Factor Analysis is used to calculate the principal components of the data. K-fold cross-validation then determines the selection of model parameters and accounts for color variation in the data. Based on this process, the final models are trained on supernovae that have been dereddened using the Fitzpatrick and Massa extinction relation. Three final models are presented here: SNEMO2, a two-component model for comparison with current Type Ia models; SNEMO7, a seven-component model chosen for standardizing supernova magnitudes, which results in a total dispersion of 0.100 mag for a validation set of supernovae, of which 0.087 mag is unexplained (a total dispersion of 0.113 mag with an unexplained dispersion of 0.097 mag is found for the total set of training and validation supernovae); and SNEMO15, a comprehensive 15-component model that maximizes the amount of spectral time-series behavior captured.

79 ASTRONOMY AND ASTROPHYSICS↗

Suppressing heating rate-dependent martensitic stabilization in ductile Cu-Al-Mn shape memory alloys by Ni addition: An experimental and first-principles study

Highlights: • Additional nearest neighbor bond between Ni and Al atoms was produced theoretically in the Cu-Al-Mn-Ni (Ni≤2 at.%) alloys. • Shape memory effect of Cu-Al-Mn alloys heated at 20 K/min was improved from 85% to 92% after the addition of 2 at.% Ni. • Addition of 2 at.% Ni can suppress heating rate-dependent martensitic stabilization in Cu-Al-Mn alloys heated at 0.01 K/min. - Abstract: The present paper aims to suppress the heating rate-dependent martensitic stabilization of ductile Cu-Al-Mn shape memory alloys through restricting the mobility and thus the behavior of vacancies. A combined study based on first-principles calculation and experimental results were presented to unveil the effect of Ni addition into ternary Cu-Al-Mn alloys on the bonding force between atoms. The results showed that additional nearest neighbor bond between Ni and Al atoms in quaternary Cu-Al-Mn-Ni alloys can be produced. The addition of Ni (≤2 at.%) into ternary Cu-Al-Mn alloys can not only efficiently increase the shape memory effect, but also suppress the occurrence of heating rate-dependent martensitic stabilization. The addition of 2 at.% Ni improved the shape memory effect of ternary Cu-Al-Mn alloys from 85% to 92% when heated at 20 k/min. The shape memory effect of ternary Cu-Al-Mn alloys dropped to 10% as the heating rate decreased to 1 K/min, but it remain at 92% even when the heating rate was sufficiently lowered to 0.01 K/min after the addition of 2 at.% Ni.

36 MATERIALS SCIENCE↗

A heterodyne dispersion interferometer for wide bandwidth density measurements on DIII-D

In order to improve both the density and particularly the temporal resolution beyond previous dispersion interferometers (DIs), a heterodyne technique based on an acousto-optic (AO) cell has been added to the DI. A 40 MHz drive frequency for the AO cell allows density fluctuation measurements into the MHz range. A CO 2 laser-based heterodyne DI (HDI) installed on DIII-D has demonstrated that the HDI is capable of tracking the density evolution throughout DIII-D discharges, including disruption events and other rapid transient phenomena. The data also show good agreement with independent density measurements obtained with the existing DIII-D two-color interferometer. The HDI line-integrated density resolution sampled over a 1 s interval is ~9 × 10 17 m -2 . Density fluctuations induced by MHD instabilities are also successfully measured by the HDI.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Non-inductive vertical position measurements by Faraday-effect polarimetry on EAST tokamak

Vertical instability control in an elongated plasma is highly desirable for a tokamak reactor. A multi-channel 694 GHz far-infrared laser-based polarimeter-interferometer system has been used to provide a non-inductive vertical position measurement in the long-pulse EAST tokamak. A detailed comparison of vertical position measurements by polarimetry and external inductive flux loops has been used to validate Faraday-effect polarimetry as an accurate high-time response vertical position sensor.

47 OTHER INSTRUMENTATION↗

Tests of a full-scale ITER toroidal interferometer and polarimeter (TIP) prototype on the DIII-D tokamak (invited)

A full-scale ITER toroidal interferometer and polarimeter (TIP) prototype, including an active feedback alignment system, has been installed and tested on the DIII-D tokamak. In the TIP prototype, a two-color interferometry measurement of line-integrated density is carried out at 10.59 μm and 5.22 μm using a CO 2 and quantum cascade laser, respectively, while a separate polarimetry measurement of the plasma-induced Faraday effect is made at 10.59 μm. The TIP prototype is equipped with a piezo tip/tilt stage active feedback alignment system that minimizes noise in the measurement and keeps the diagnostic aligned throughout DIII-D discharges. The measured phase resolution for the polarimeter and interferometer is 0.05° (100 Hz bandwidth) and 1.9° (1 kHz bandwidth), respectively. Here, the corresponding line-integrated density resolution for the vibration-compensated interferometer is δnL = 1.5 × 10 18 m -2 , and the magnetic field-weighted line-integrated density from the polarimeter is δnBL = 1.5 × 10 19 Tm -2 . Both interferometer and polarimeter measurements during DIII-D discharges compare well with the expectations based on calculations using Thomson scattering measured density profiles and magnetic equilibrium reconstructions. Additionally, larger bandwidth interferometer measurements show that the diagnostic is a sensitive monitor of core density fluctuations with demonstrated measurements of Alfvén eigenmodes and tearing modes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Faraday-effect polarimeter for fast magnetic dynamics measurement on DIII-D

A Faraday-effect-based radial-interferometer-polarimeter diagnostic has been developed to explore fast magnetic dynamics in high-performance DIII-D plasmas. The instrument measures radial magnetic field perturbations using three chords positioned near the magnetic axis. Newly developed solid-state sources operating at 650 GHz provide phase noise down to 0.01°/$\sqrt{kHz}$ and tunable bandwidth up to 10 MHz. Various systematic errors which can contaminate the polarimetric measurement have been investigated in detail. Distortion of circular polarization due to non-ideal optical components is calibrated using a rotating quarter wave plate technique. The impact of perpendicular magnetic field, i.e., the Cotton-Mouton effect, is evaluated. The error due to non-collinearity of probe beams is minimized to less than 0.5° for electron density up to 7 × 10 19 m -3 by alignment optimization. Optical feedback, due to multiple reflections induced by the double-pass configuration, is identified and reduced. Lastly, coherent and broadband high-frequency magnetic fluctuations for DIII-D H-mode plasmas are observed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impact of the Cotton–Mouton effect on Faraday polarimetry measurements using circular polarization

Here, a comprehensive understanding of the impact of Cotton-Mouton Effect on Faraday polarimetry measurements using counter-rotating circular polarization probe beams has been developed. By using Jones theory, analytic study shows the Cotton-Mouton Effect cancels to first order with coupling into the Faraday measurement only at higher order. Jones-based numerical study shows the coupling effect strongly depends on the Cotton-Mouton Effect, Faraday Effect and wavelength chosen for the measurement. For realistic DIII-D plasma conditions and far-infrared wavelength, numerical calculation suggests the measurement is dominated by Faraday Effect while coupling effect leads to small but finite correction. By statistical comparison between experimental measurement and Jones-based numerical calculation under various plasma parameters, the impact of Cotton-Mouton Effect has been verified. Proper treatment of the coupling effect is essential in data analysis under certain conditions for polarimetric measurement using circular polarization in present devices and beyond.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Probing the Single-Particle Character of Rotational States in F 19 Using a Short-Lived Isomeric Beam

A beam containing a substantial component of both the J π = 5 + , T 1 / 2 = 162 ns isomeric state of F 18 and its 1 + , 109.77-min ground state is utilized to study members of the ground-state rotational band in F 19 through the neutron transfer reaction ( d , p ) in inverse kinematics. The resulting spectroscopic strengths confirm the single-particle nature of the 13 / 2 + band-terminating state. The agreement between shell-model calculations using an interaction constructed within the s d shell, and our experimental results reinforces the idea of a single-particle–collective duality in the descriptions of the structure of atomic nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spatial Distortion of Vibration Modes via Magnetic Correlation of Impurities

Long wavelength vibrational modes in the ferromagnetic semiconductor Ga 0.91 M n0.09 As are investigated using time resolved x-ray diffraction. At room temperature, we measure oscillations in the x-ray diffraction intensity corresponding to coherent vibrational modes with well-defined wavelengths. When the correlation of magnetic impurities sets in, we observe the transition of the lattice into a disordered state that does not support coherent modes at large wavelengths. Our measurements point toward a magnetically induced broadening of long wavelength vibrational modes in momentum space and their quasilocalization in the real space. More specifically, long wavelength vibrational modes cannot be assigned to a single wavelength but rather should be represented as a superposition of plane waves with different wavelengths. Lastly, our findings have strong implications for the phonon-related processes, especially carrier-phonon and phonon-phonon scattering, which govern the electrical conductivity and thermal management of semiconductor-based devices.

36 MATERIALS SCIENCE↗

Neutron knockout from 68,70 Ni ground and isomeric states

Neutron-rich isotopes are an important source of new information on nuclear physics. Specifically, the spin-isospin components in the nucleon-nucleon (NN) interaction, e.g., the proton-neutron tensor force, are expected to modify shell structure in exotic nuclei. These potential changes in the intrinsic shell structure are of fundamental interest. The study of the excitation energy of states corresponding to specific configurations in even-even isotopes, together with the single-particle character of the first excited states of odd-A, neutron-rich Ni isotopes, probes the evolution of the neutron orbitals around the Fermi surface as a function of the neutron number a step forward in the understanding of the region and the nature of the NN interaction at large N/Z ratios. In an experiment carried out at the National Superconducting Cyclotron Laboratory, new spectroscopic information was obtained for 68 Ni and the distribution of single-particle strengths in 67,69 Ni was characterized by means of single-neutron knockout from 68,70 Ni secondary beams. The spectroscopic strengths, deduced from the measured partial cross sections to the individual states tagged by their de-exciting gamma rays, is used to identify and quantify configurations that involve neutron excitations across the N = 40 harmonic oscillator shell closure. Finally, the de-excitation rays were measured with the GRETINA tracking array.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An optimized prototype of electromagnetic calorimeter for the SoLID project at Jefferson Lab

A shashlik-type electromagnetic calorimeter will be produced in Hall A of Jefferson Laboratory for the Solenoidal Large Intensity Device (SoLID). Wavelength-shifting (WLS) fibers and clear fibers will be used as the light guide part of the calorimeter. The blue light from scintillators is converted into green light by WLS fibers and is carried out to the back of the calorimeters for readout. Since the magnetic field of SoLID reaches about 1.5 T behind the calorimeters, the design is to use clear fibers to further guide the light out of the solenoid for readout by PMTs. Therefore, it is important to study the perfomance of WLS and clear fibers. This paper describes a comparative test of two different WLS fibers and a light attenuation test for a clear fiber. The results show that the performance of the two WLS fibers is the same under large curvature bending, and that the bending has no effect on the light transmission through the clear fiber. In addition, a comparison test for two fiber end-face reflective materials is also reported. It reveals that the use of silver ink as a reflective material can increase the light yield by 30%. Thereby, an optimized prototype based on the above experimental results was built and the basic performance was tested.

Shen, C.↗

Effects of stray lights on Faraday rotation measurement for polarimeter-interferometer system on EAST

A double-pass radially view 11 chords polarimeter-interferometer system has been operated on the experimental advanced superconducting tokamak and provides important current profile information for plasma control. Stray light originating from spurious reflections along the optical path (unwanted reflections from various optical components/mounts and transmissive optical elements such as windows, waveplates, and lens as well as the detectors) and also direct feedback from the retro-reflector used to realize the double-pass configuration can both contribute to contamination of the Faraday rotation measurement accuracy. Modulation of the Faraday rotation signal due to the interference from multiple reflections is observable when the interferometer phase (plasma density) varies with time. Direct reflection from the detector itself can be suppressed by employing an optical isolator consisting of a λ/4-waveplate and polarizer positioned in front of the mixer. A Faraday angle oscillation during the density ramping up (or down) can be reduced from 5°–10° to 1°–2° by eliminating reflections from the detector. Residual modulation arising from misalignment and stray light from other sources must be minimized to achieve accurate measurements of Faraday rotation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using a Fluorescent 1-Methyl-4-(2-Pyren-1-Yl-Vinyl)-Pyridinium Iodide to Characterize Solvent Polarities

We used 1-methyl-4-(2-pyren-1-yl-vinyl)-pyridinium iodide, a pyridinium derivative fluorescent dye, as a solvatochromic and solvatofluorchromic probe to straightforwardly characterize the solvent polarity. The absorption and fluorescence spectra of 1-methyl-4-(2-pyren-1-yl-vinyl)-pyridinium iodide show a dramatic dependence on solvent polarities in the high-polar range. It exhibits two absorption peaks around 400 and 450 nm, as well as an emission maximum at 605 nm. Several parameters (ratio of the two absorption peaks, wavelength of the principal absorption peak, fluorescence signal, and ratio of fluorescence intensities excited at the two absorption bands) are linearly dependent on the solvent polarity–polarizability values. Strong correlations have been also obtained with the P' and P{sub y} polarity scales with small deviations. Moreover, 1-methyl-4-(2-pyren-1-yl-vinyl)-pyridinium iodide possesses high fluorescence quantum yield (0.38–0.54) and relatively long lifetime (2.2–2.6 ns) in all studied organic solvents. All these optical properties make 1-methyl-4-(2-pyren-1-yl-vinyl)-pyridinium iodide a favorable probe to quantitatively characterize the solvent polarities in the high-polar range through a multiparametric approach.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗