Engineering Papers⌕ Search

Engineering topics

Chen, A

Publications and source records attributed to Chen, A.

At least 19 records

SPATIAL GRAPH ATTENTION AND CURIOSITY-DRIVEN POLICY FOR ANTIVIRAL DRUG DISCOVERY

We developed Distilled Graph Attention Policy Network (DGAPN), a reinforcement learning model to generate novel graph-structured chemical representations that optimize user-defined objectives by efficiently navigating a physically constrained domain. The framework is examined on the task of generating molecules that are designed to bind, noncovalently, to functional sites of SARS-CoV-2 proteins. We present a spatial Graph Attention (sGAT) mechanism that leverages self-attention over both node and edge attributes as well as encoding the spatial structure - this capability is of considerable interest in synthetic biology and drug discovery. An attentional policy network is introduced to learn the decision rules for a dynamic, fragment-based chemical environment, and state-of-the-art policy gradient techniques are employed to train the network with stability. Exploration is driven by the stochasticity of the action space design and the innovation reward bonuses learned and proposed by random network distillation. In experiments, our framework achieved outstanding results compared to state-of-the-art algorithms, while reducing the complexity of paths to chemical synthesis.

Wu, Y↗

SU-F-J-17: Patient Localization Using MRI-Guided Soft Tissue for Head-And-Neck Radiotherapy: Indication for Margin Reduction and Its Feasibility

Purpose: On-board MRI provides superior soft-tissue contrast, allowing patient alignment using tumor or nearby critical structures. This study aims to study H&N MRI-guided IGRT to analyze inter-fraction patient setup variations using soft-tissue targets and design appropriate CTV-to-PTV margin and clinical implication. Methods: 282 MR images for 10 H&N IMRT patients treated on a ViewRay system were retrospectively analyzed. Patients were immobilized using a thermoplastic mask on a customized headrest fitted in a radiofrequency coil and positioned to soft-tissue targets. The inter-fraction patient displacements were recorded to compute the PTV margins using the recipe: 2.5∑+0.7σ. New IMRT plans optimized on the revised PTVs were generated to evaluate the delivered dose distributions. An in-house dose deformation registration tool was used to assess the resulting dosimetric consequences when margin adaption is performed based on weekly MR images. The cumulative doses were compared to the reduced margin plans for targets and critical structures. Results: The inter-fraction displacements (and standard deviations), ∑ and σ were tabulated for MRI and compared to kVCBCT. The computed CTV-to-PTV margin was 3.5mm for soft-tissue based registration. There were minimal differences between the planned and delivered doses when comparing clinical and the PTV reduced margin plans: the paired t-tests yielded p=0.38 and 0.66 between the planned and delivered doses for the adapted margin plans for the maximum cord and mean parotid dose, respectively. Target V95 received comparable doses as planned for the reduced margin plans. Conclusion: The 0.35T MRI offers acceptable soft-tissue contrast and good spatial resolution for patient alignment and target visualization. Better tumor conspicuity from MRI allows soft-tissue based alignments with potentially improved accuracy, suggesting a benefit of margin reduction for H&N radiotherapy. The reduced margin plans (i.e., 2 mm) resulted in improved normal structure sparing and accurate dose delivery to achieve intended treatment goal under MR guidance.

60 APPLIED LIFE SCIENCES↗

SU-F-J-181: An Alternative Patient Alignment Tool On TomoTherapy: The First In- Human Megavoltage-Topogram Acquisition

Purpose: To show the first in-human Megavoltage (MV)-Topogram acquisition for the evaluation of the potential for MV-Topogram-based alignment as an alternative to MVCT for reducing dose and imaging time. Methods: A lung cancer patient was enrolled in an ongoing IRB-approved clinical trial at our institute. The patient was set up using the clinical protocol employing positioning lasers. 3.2mm diameter tungsten spheres were placed on the patient’s skin at their alignment tattoos to check surface-based marker concordance between topograms and MVCT. Anterior-Posterior (AP) and lateral (LAT) MV-Topograms were acquired using gantry angles of 0°/90° with a 1mm collimator opening, all MLC leafs open, 4cm/s couch speed, and 12.5s scanning time. The topogram acquisition was immediately followed by the normal MVCT scan acquisition. MV-Topograms were reconstructed from the detector exit-data using in-house developed software. The topograms were also enhanced using contrast-limited adaptive histogram equalization (CLAHE). The MV-Topograms were registered to reference kV-based digitally reconstructed topograms. The localization results were compared against results obtained comparing the clinical MVCT to the kVCT simulation. Results: The shifts using the unenhanced Topograms, enhanced Topograms, and MVCT were (LAT, LONG, VERT, ROLL) (5.8mm, 2.6mm, −5.6mm, 0.34°), (3.9mm, 2.5mm, −2.2mm, 0.65°) and (2.4mm, 1.5mm, −3.0mm, 0.5°), respectively. The magnitude alignment differences between the enhanced Topograms and MVCT were within 1.5 mm and 0.15°. The average MVCT and total Topogram acquisition times were 272.9s ± 31.5s and 46s, respectively. Conclusion: MV-Topograms have the potential for providing equivalent performance with less dose and acquisition time than the traditional MVCT technique. We are evaluating other sites as well as adding patients to develop statistically significant analyses regarding the alignment quality differences. MV-Topograms are likely to be most clinically useful for bony anatomy and radiopaque marker-based alignments. The study was supported by an Accuray Grant.

60 APPLIED LIFE SCIENCES↗

Measurement of the decay B → D ℓ ν ℓ in fully reconstructed events and determination of the Cabibbo-Kobayashi-Maskawa matrix element | V c b |

We present a determination of the magnitude of the Cabibbo-Kobayashi-Maskawa matrix element |Vcb| using the decay B → Dℓν ℓ (ℓ = e,μ) based on 711 fb –1 of e + e – → Υ(4S) data recorded by the Belle detector and containing 772 × 10 6 BB¯ pairs. Here, one B meson in the event is fully reconstructed in a hadronic decay mode, while the other, on the signal side, is partially reconstructed from a charged lepton and either a D + or D 0 meson in a total of 23 hadronic decay modes. The isospin-averaged branching fraction of the decay B → Dℓν ℓ is found to be B(B 0 → D – ℓ + ν ℓ ) = (2.31 ± 0.03(stat) ± 0.11(syst))%. Analyzing the differential decay rate as a function of the hadronic recoil with the parametrization of Caprini, Lellouch, and Neubert and using the form-factor prediction G(1) = 1.0541 ± 0.0083 calculated by FNAL/MILC, we obtain η EW |V cb | = (40.12 ± 1.34) × 10 –3 , where ηEW is the electroweak correction factor. Alternatively, assuming the model-independent form-factor parametrization of Boyd, Grinstein, and Lebed and using lattice QCD data from the FNAL/MILC and HPQCD collaborations, we find η EW |V cb | = (41.10 ± 1.14) × 10 –3 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First observation of the decay B 0 → ψ ( 2 S ) π 0

We report a measurement of the B 0 → ψ(2S)π 0 branching fraction based on the full Υ(4S) data set of 772 × 10 6 BB¯ pairs collected by the Belle detector at the KEKB asymmetric-energy e + e – collider. We obtain B(B 0 → ψ(2S)π 0 ) = (1.17 ± 0.17(stat) ± 0.08(syst)) × 10 –5 . Here, the result has a significance of 7.2 standard deviations and is the first observation of the decay B 0 → ψ(2S)π 0 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evidence for the decay B 0 → η π 0

In this work, we report a search for the charmless hadronic decay B 0 → η π 0 with a data sample corresponding to an integrated luminosity of 694 fb - 1 containing 753 × 1 0 6 B B ¯ pairs. The data were collected by the Belle experiment running on the Υ ( 4 S ) resonance at the KEKB e + e - collider. We measure a branching fraction B ( B 0 → η π 0 ) = ( 4. 1 - 1.5 - 0.7 + 1.7 + 0.5 ) × 1 0 - 7 , where the first uncertainty is statistical and the second is systematic. Our measurement gives an upper limit of B ( B 0 → η π 0 ) < 6.5 × 1 0 - 7 at 90% confidence level. Finally, the signal has a significance of 3.0 standard deviations and constitutes the first evidence for this decay mode.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the direct CP asymmetry in B¯->Xs+dy decays with a lepton tag

We report the measurement of the direct CP asymmetry in the radiative B¯?Xs+d? decay using a data sample of (772±11)×106 BB¯ pairs collected at the ?(4S) resonance with the Belle detector at the KEKB asymmetric-energy e+e- collider. The CP asymmetry is measured as a function of the photon energy threshold. For E*?=2.1 GeV, where E*? is the photon energy in the center-of-mass frame, we obtain ACP(B¯?Xs+d?)=(2.2±3.9±0.9)%, consistent with the Standard Model prediction.

Pesantez, L↗

Observation of X ( 3872 ) in B → X ( 3872 ) K π decays

We report the first observation of B 0 →X(3872)(K + π – ) and evidence for B + → X(3872)(K 0 π + ). We measure the product of branching fractions for the former to be B(B 0 → X(3872)(K + π – )) × B(X(3872) → J/ψπ + π – ) = (7.9 ± 1.3(stat) ± 0.4(syst)) × 10 –6 and find that B 0 → X(3872)K*(892) 0 does not dominate the B 0 → X(3872)K + π – decay mode. We also measure B(B + → X(3872)(K 0 π + )) × B(X(3872) → J/ψπ + π – ) = (10.6 ± 3.0(stat) ± 0.9(syst)) × 10 –6 . Furthermore, this study is based on the full data sample of 711 fb –1 (772 × 10 6 BB¯ pairs) collected at the Υ(4S) resonance with the Belle detector at the KEKB collider.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MO-G-BRF-01: BEST IN PHYSICS (JOINT IMAGING-THERAPY) - Sensitivity of PET-Based Texture Features to Respiratory Motion in Non-Small Cell Lung Cancer (NSCLC)

Purpose: PET-based texture features are used to quantify tumor heterogeneity due to their predictive power in treatment outcome. We investigated the sensitivity of texture features to tumor motion by comparing whole body (3D) and respiratory-gated (4D) PET imaging. Methods: Twenty-six patients (34 lesions) received 3D and 4D [F-18]FDG-PET scans before chemo-radiotherapy. The acquired 4D data were retrospectively binned into five breathing phases to create the 4D image sequence. Four texture features (Coarseness, Contrast, Busyness, and Complexity) were computed within the the physician-defined tumor volume. The relative difference (δ) in each measure between the 3D- and 4D-PET imaging was calculated. Wilcoxon signed-rank test (p<0.01) was used to determine if δ was significantly different from zero. Coefficient of variation (CV) was used to determine the variability in the texture features between all 4D-PET phases. Pearson correlation coefficient was used to investigate the impact of tumor size and motion amplitude on δ. Results: Significant differences (p<<0.01) between 3D and 4D imaging were found for Coarseness, Busyness, and Complexity. The difference for Contrast was not significant (p>0.24). 4D-PET increased Busyness (∼20%) and Complexity (∼20%), and decreased Coarseness (∼10%) and Contrast (∼5%) compared to 3D-PET. Nearly negligible variability (CV=3.9%) was found between the 4D phase bins for Coarseness and Complexity. Moderate variability was found for Contrast and Busyness (CV∼10%). Poor correlation was found between the tumor volume and δ for the texture features (R=−0.34−0.34). Motion amplitude had moderate impact on δ for Contrast and Busyness (R=−0.64− 0.54) and no impact for Coarseness and Complexity (R=−0.29−0.17). Conclusion: Substantial differences in textures were found between 3D and 4D-PET imaging. Moreover, the variability between phase bins for Coarseness and Complexity was negligible, suggesting that similar quantification can be obtained from all phases. Texture features, blurred out by respiratory motion during 3D-PET acquisition, can be better resolved by 4D-PET imaging with any phase.

60 APPLIED LIFE SCIENCES↗

SU-E-J-127: Real-Time Dosimetric Assessment for Adaptive Head-And-Neck Treatment Via A GPU-Based Deformable Image Registration Framework

Purposes: To systematically monitor anatomic variations and their dosimetric consequences during head-and-neck (H'N) radiation therapy using a GPU-based deformable image registration (DIR) framework. Methods: Eleven H'N IMRT patients comprised the subject population. The daily megavoltage CT and weekly kVCT scans were acquired for each patient. The pre-treatment CTs were automatically registered with their corresponding planning CT through an in-house GPU-based DIR framework. The deformation of each contoured structure was computed to account for non-rigid change in the patient setup. The Jacobian determinant for the PTVs and critical structures was used to quantify anatomical volume changes. Dose accumulation was performed to determine the actual delivered dose and dose accumulation. A landmark tool was developed to determine the uncertainty in the dose distribution due to registration error. Results: Dramatic interfraction anatomic changes leading to dosimetric variations were observed. During the treatment courses of 6–7 weeks, the parotid gland volumes changed up to 34.7%, the center-of-mass displacement of the two parotids varied in the range of 0.9–8.8mm. Mean doses were within 5% and 3% of the planned mean doses for all PTVs and CTVs, respectively. The cumulative minimum/mean/EUD doses were lower than the planned doses by 18%, 2%, and 7%, respectively for the PTV1. The ratio of the averaged cumulative cord maximum doses to the plan was 1.06±0.15. The cumulative mean doses assessed by the weekly kVCTs were significantly higher than the planned dose for the left-parotid (p=0.03) and right-parotid gland (p=0.006). The computation time was nearly real-time (∼ 45 seconds) for registering each pre-treatment CT to the planning CT and dose accumulation with registration accuracy (for kVCT) at sub-voxel level (<1.5mm). Conclusions: Real-time assessment of anatomic and dosimetric variations is feasible using the GPU-based DIR framework. Clinical implementation of this technology may enable timely plan adaption and potentially lead to improved outcome.

60 APPLIED LIFE SCIENCES↗

Measurement of the inclusive semileptonic branching fraction B ( B s 0 → X - ℓ + ν ℓ ) at Belle

Here, we report a measurement of the inclusive semileptonic B s 0 branching fraction in a 121 fb - 1 data sample collected near the Υ ( 5 S ) resonance with the Belle detector at the KEKB asymmetric energy e + e - collider. Events with B s 0 ( * ) B ¯ s 0 ( * ) pairs are selected by reconstructing a tag side D s + and identifying a signal side lepton ℓ + ( ℓ = e , μ ) that is required to have the same-sign charge to ensure that both originate from different B s 0 mesons. The B s 0 → X - ℓ + ν ℓ branching fraction is extracted from the ratio of the measured yields of D s + mesons and D s + ℓ + pairs and the known production and branching fractions. The inclusive semileptonic branching fraction is measured to be [ 10.6 ± 0.5 ( stat ) ± 0.7 ( syst ) ] % .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Surface Ocean CO2 Atlas (SOCAT) gridded data products

A well documented, publicly available, global data set for surface ocean carbon dioxide (CO2) parameters has been called for by international groups for nearly two decades. The Surface Ocean CO2 Atlas (SOCAT) project was initiated by the international marine carbon science community in 2007 with the aim of providing a comprehensive, publicly available, regularly updated, global data set of marine surface CO2, which had been subject to quality control (QC). SOCAT version 1.5 was made public in September 2011 and holds 6.3 million quality controlled surface CO2 data from the global oceans and coastal seas, spanning four decades (1968 2007). The SOCAT gridded data is the second data product to come from the SOCAT project. Recognizing that some groups may have trouble working with millions of measurements, the SOCAT gridded product was generated to provide a robust regularly spaced fCO2 product with minimal spatial and temporal interpolation which should be easier to work with for many applications. Gridded SOCAT is rich with information that has not been fully explored yet, but also contains biases and limitations that the user needs to recognize and address.

gridded data↗

Experimental challenge to nuclear physics problems in the {nu}p-process

Astrophysical stellar reactions at extremely high temperatures involve a variety of problems both in nuclear reactions and nuclear structures. Specifically, the problems in the {nu}pprocess were discussed in this talk based on our recent experimental results with low-energy RI beams and a simulation study. The {nu}p-process is one of the key processes for investigating the mechanism of type II supernovae, and the process could be possibly responsible for 'the excess production' of p-nuclei around mass 90-100. Alpha cluster resonances have been discovered experimentally to play a crucial role for the stellar ({alpha}, p) reactions just above the alpha threshold. Neutron induced reactions in the proton-rich nuclear regions in the {nu}p-process are also suggested to play an important role, which involve nuclear structures of high level density at high excitation energies, probably giant resonances. The discussion also covered the p-nuclei production through the {nu}p-process at around mass 100.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design Considerations for an MEBT Chopper Absorber of 2.1 MeV H- at the Project X Injector Experiment at Fermilab

The Project X Injector Experiment (PIXIE) will be a prototype of the Project X front end that will be used to validate the design concept and decrease technical risks. One of the most challenging components of PIXIE is the wide-band chopping system of the Medium Energy Beam Transport (MEBT) section, which will form an arbitrary bunch pattern from the initially CW 162.5 MHz 5mA beam. The present scenario assumes diverting 80% of the beam to an absorber to provide a beam with the average current of 1mA to SRF linac. This absorber must withstand a high level of energy deposition and high ion fluence, while being positioned in proximity of the superconductive cavities. This paper discusses design considerations for the absorber. Thermal and mechanical analyses of a conceptual design are presented, and future plans for the fabrication and testing of a prototype are described.

43 PARTICLE ACCELERATORS↗

Progress with PXIE MEBT Chopper

A capability to provide a large variety of bunch patterns is crucial for the concept of the Project X serving MW-range beam to several experiments simultaneously. This capability will be realized by the Medium Energy Beam Transport's (MEBT) chopping system that will divert 80% of all bunches of the initially 5 mA, 2.1 MeV CW 162.5 MHz beam to an absorber according to a pre-programmed bunch-by-bunch selection. Being considered one of the most challenging components, the chopping system will be tested at the Project X Injector Experiment (PXIE) facility that will be built at Fermilab as a prototype of the Pojrect X front end. The bunch deflection will be made by two identical sets of travelling-wave kickers working in sync. Presently, two versions of the kickers are being investigated: a helical 200 Ohm structure with a switching-type 500 V driver and a planar 50 Ohm structure with a linear {+-} 250 V amplifier. This paper describes the chopping system scheme and functional specifications for the kickers, present results of electromagnetic measurements of the models, discuss possible driver schemes, and show a conceptual mechanical design.

43 PARTICLE ACCELERATORS↗