Engineering PapersSearch

Engineering topics

Chedin, A.

Publications and source records attributed to Chedin, A..

Simultaneous Retrieval of Temperature, Water Vapor and Ozone Atmospheric Profiles from IASI: Compression, De-noising, First Guess Retrieval and Inversion Algorithms

A fast temperature water vapor and ozone atmospheric profile retrieval algorithm is developed for the high spectral resolution Infrared Atmospheric Sounding Interferometer (IASI) space-borne instrument. Compression and de-noising of IASI observations are performed using Principal Component Analysis. This preprocessing methodology also allows, for a fast pattern recognition in a climatological data set to obtain a first guess. Then, a neural network using first guess information is developed to retrieve simultaneously temperature, water vapor and ozone atmospheric profiles. The performance of the resulting fast and accurate inverse model is evaluated with a large diversified data set of radiosondes atmospheres including rare events.

Aires, F.

A Regularized Neural Net Approach for Retrieval of Atmospheric and Surface Temperatures with the IASI Instrument

Abstract In this paper, a fast atmospheric and surface temperature retrieval algorithm is developed for the high resolution Infrared Atmospheric Sounding Interferometer (IASI) space-borne instrument. This algorithm is constructed on the basis of a neural network technique that has been regularized by introduction of a priori information. The performance of the resulting fast and accurate inverse radiative transfer model is presented for a large divE:rsified dataset of radiosonde atmospheres including rare events. Two configurations are considered: a tropical-airmass specialized scheme and an all-air-masses scheme.

Aires, F.

Comparisons of Upper Tropospheric Humidity Retrievals from TOVS and METEOSAT

Two different methods for retrieving Upper Tropospheric Humidities (UTH) from the TOVS (TIROS Operational Vertical Sounder) instruments aboard NOAA polar orbiting satellites are presented and compared. The first one, from the Environmental Technology Laboratory, computed by J. Bates and D. Jackson (hereafter BJ method), estimates UTH from a simplified radiative transfer analysis of the upper tropospheric infrared water vapor channel at wavelength measured by HIRS (6.3 micrometer). The second one results from a neural network analysis of the TOVS (HIRS and MSU) data developed at, the Laboratoire de Meteorologie Dynamique (hereafter the 3I (Improved Initialization Inversion) method). Although the two methods give very similar retrievals in temperate regions (30-60 N and S), an absolute bias up to 16% appears in the convective zone of the tropics. The two datasets have also been compared with UTH retrievals from infrared radiance measurements in the 6.3 micrometer channel from the geostationary satellite METEOSAT (hereafter MET method). The METEOSAT retrievals are systematically drier than the TOVS-based results by an absolute bias between 5 and 25%. Despite the biases, the spatial and temporal correlations are very good. The purpose of this study is to explain the deviations observed between the three datasets. The sensitivity of UTH to air temperature and humidity profiles is analysed as are the clouds effects. Overall, the comparison of the three retrievals gives an assessment of the current uncertainties in water vapor amounts in the upper troposphere as determined from NOAA and METEOSAT satellites.

Escoffier, C.

Satellite observations of polar lows by SSM/I, Geosat and TOVS

Satellite observations in high-latitude regions were used to detect polar lows and track their propagation and evolution. The Special Sensor Microwave/Imager (SSM/I) provided estimates of surface wind speed, integrated cloud liquid water, and water vapor contents over ocean; the Geosat radar altimeter measured surface wind speed and significant wave height; the TIROS-N Operational Vertical Sounder (TOVS) allowed the determination of temperature and humidity profiles in the atmosphere, as well as cloud information (cloud top pressure and temperature). The detection of polar lows at a very early stage, and their development, propagation, and decay is presented for a specific case occurring in the Norwegian Sea on 23-24 January 1988, using a combination of these three instruments, namely a passive and an active microwave sensor, and a vertical sounder (19 infrared, 1 visible, and 4 microwave channels). Advantage is taken of the time and coverage differences between these three satellite sensors for the observation of polar lows. A discussion of the results is given.

Claud, C.

The GEISA spectroscopic line parameters data bank in 1984

The 1984 update of the GEISA data bank, containing spectroscopic information on 323,521 lines corresponding to 36 molecules and 79 isotopic species in the spectal range 3 x 10 to the -6th/cm to 17,879/cm, is discussed. The bank compiles parameters describing the radiation absorption or emission properties of gases involved in the atmospheres of the earth and planets. Values of a new exponent which summarized the variation of the collision halfwidth with temperature are given for 10 molecules. Six new molecules, HOCl, N2, CH3Cl, H2O2, H2S, and HCOOH, are included in this edition.

Husson, N.

AFGL trace gas compilation - 1982 version

The new edition of the AFGL trace gas compilation is described. The latest version provides the necessary parameters for the computation of absorption or emission spectra of major bands of twenty-one gases in the region from 0 to 10,000 per cm. Emphasis in this edition has been on the addition of numerous millimeter and submillimeter transitions, the inclusion of bands of significance in upper atmospheric processes, and strong IR bands of trace constituents likely to be used for remote detection. The sources for the additions and modifications of the absorption parameters are summarized.

Rothman, L. S.

The C/H ratio in Jupiter from the Voyager infrared investigation

From a selection Voyager IRIS spectra corresponding to cloud-free areas of Jupiter, the CH4/H2 volume ratio in the atmosphere of this planet has been determined to be equal to 0.00195 + or - 0.00022, which corresponds to 2.07 + or - 0.24 times the solar value of Lambert (C/H = 0.00047). The estimate of errors includes both instrument noise and systematic uncertainties. Implications of this result for the formation and evolution of Jupiter are discussed.

Gautier, D.

The tropospheric gas composition of Jupiter's north equatorial belt (NH3, PH3, CH3D, GeH4, H2O) and the Jovian D/H isotropic ratio

The gas composition of the troposphere of Jupiter in the clearest regions of the North Equatorial Belt (NEB) was derived from the Voyager 1 IRIS data. The infrared spectrum for this homogeneous cloud free region was modeled to infer altitude profiles for NH3, PH3, GeH4 and H2O. The Profiles for NH3 and PH3 were found to be depleted in the upper troposphere but otherwise in agreement with their solar values at the 1 bar level. The mole fraction for CH3D was determined to be 3.5(+1.0 or -1.3) x 10 to the minus 7th power. The GeH4 mole fraction of 7+ or -2 x 10 to the minus 10th power at the 2 to 3 bar level is a factor of 10 lower than the solar value. The H2O mole fraction is approximately 1 x 0.00001 at the 2.5 bar level and is increasing to approximately 3 x 0.00001 at 4 bars where it is a factor of 30 lower than solar. Using IRIS infrared values for the mole fractions of CH3D and CH4 a value of D/H = 3.6(+1.0 or -1.4)x 0.00001 is derived. Assuming this Jovian D/H ratio is representative of the protosolar nebula, and correcting for chemical galactic evolution, yields a value of 5.5 - 9.0 x 0.00001 for the primordial D/H ratio and an upper limit of 1.8 to 2.4 x 10 to the minus 31st power cu cm for the present day baryon density.

Kunde, V.

The helium abundance of Jupiter from Voyager

The helium abundance in the Jovian atmosphere is derived from Voyager 1 data by two methods. The first method uses only infrared spectra from selected locations on the planet while the second method uses a thermal profile independently derived from radio occultation measurements and infrared spectra recorded near the occultation point. A hydrogen mole fraction of 0.897 plus or minus 0.030 is obtained from the first method, while the second method gives 0.880 plus or minus 0.036, corresponding to helium mass fractions of 0.19 plus or minus 0.05 and 0.21 plus or minus 0.06, respectively. The estimated errors for the first method are primarily due to systematic uncertainties in the H2 and He absorption coefficients, while those for the second method result mainly from errors in the radio occultation profile and are less well known. Random errors in the measured infrared spectra are found to be negligible in both cases. The results are consistent with a uniform mix of hydrogen and helium within Jupiter's interior, but a modest amount of helium depletion (Delta Y equal to or less than 0.05) cannot be excluded.

Gautier, D.

Study of the ammonia ice cloud layer in the Equatorial Region of Jupiter from the infrared interferometric experiment on Voyager

Spectra from the Voyager 1 infrared interferometer spectrometer (IRIS) obtained near the time of closest approach to Jupiter were analyzed for the purpose of inferring ammonia cloud properties associated with the Equatorial Region. Comparisons of observed spectra with synthetic spectra computed from a radiative transfer formulation, that includes multiple scattering, yielded the following conclusions: (1) very few NH3 ice particles with radii less than 3 microns contribute to the cloud opacity; (2) the major source of cloud opacity arises from particles with radii in excess of 30 microns; (3) column particle densities are between 1 and 2 orders of magnitude smaller than those derived from thermochemical considerations alone, implying the presence of important atmospheric motion; and (4) another cloud system is confirmed to exist deeper in the Jovian troposphere.

Marten, A.

The helium abundance of Jupiter from Voyager

Full disk measurements recorded 31 days before the Voyager 1 encounter with Jupiter by the radiometer of the infrared instrument, IRIS, indicate a geometric albedo of 0.274 + or - 0.013. Combining this measurement with the Pioneer derived phase integral of 1.25 and our error estimate of 0.1 yields a Jovian Bond albedo of 0.343 + or - 0.032. Infrared spectra recorded at the same time by the Michelson interferometer, along with a model extrapolation to low wave numbers not covered by the instrument, yield a thermal emission of (1.359 + or - 0.014) .001 W cm to the (-2) power. As in the case of the albedo measurement, the quoted errors in the emission measurement reflect estimates of systematic effects and are uncertain while the random component is negligible. From these measurements the internal heat flux of Jupiter is estimated to be (5.444 + or - 0.425) .0001 W cm to the (-2) power, and the energy balance defined as the ratio of emitted thermal to absorbed solar energy is 1.668 + or - 0.085.

Gautier, D.

Physics of the atmosphere: Response of the water vapor channel of the Meteosat satellite

An accurate model of the atmospheric transmission function is used to obtain the relationship between the cloudless radiances measured by the 6-7 microns Meteosat radiometer (water vapor channel) and the numerical parameters associated to each point of an image. This relationship is compared to the temporary calibration curve published by the European Space Agency.

Roulleau, M.