A computational study of heat transfer for laminar hypervelocity flows
Computational Fluid Dynamics (CFD) codes are routinely used to predict the flowfield and the heating environment around complex reentry configurations. At hypervelocities, where the velocity is greater than 3 km/sec, the AFWAL version of the blunt body code predicts the correct surface pressure distributions but underpredicts laminar wall heat fluxes. This study was performed to determine the reasons for the underprediction. The computer code chosen solves thin-layer Navier-Stokes equations in a time-asymptotic manner and assumes a constant isentropic exponent. Flowfields around a spherical configuration at various entry velocities are computed. The computed pressure distributions agree well with the tabulated, inviscid results of Lyubimov and Rusanov for entry velocities ranging from 0.6 to 5.92 km/sec. At hypervelocities, the calculated stagnation point heat transfer rates were lower by roughly fifty percent when compared to engineering correlations available in the literature. Good comparisons between heat transfer rates are obtained at hypervelocity entry conditions provided the CFD code is modified to include equilibrium air properties.