The effect of dDAVP with saline loading on fluid balance during LBNP and standing after 24-hr head-down bedrest

Shuttle astronauts currently drink approximately a quart of water with eight salt tablets before reentry to restore lost body fluid and thereby reduce the likelihood of cardiovascular instability and syncope during reentry and after landing. However, the saline loading countermeasure is not entirely effective in restoring orthostatic tolerance to preflight levels. We tested the hypothesis that the effectiveness of this countermeasure could be improved with the use of a vasopressin analog, 1-deamino-8-D-arginine vasopressin (dDAVP). The rationale for this approach is that reducing urine formation with exogenous vasopressin should increase the magnitude and duration of the vascular volume expansion produced by the saline load, and in so doing improve orthostatic tolerance during reentry and postflight.

NASA Discipline Number 14-10↗

Comparison of cardiovascular function during the early hours of bed rest and space flight

This paper reviews the cardiovascular responses of six healthy male subjects to 6 hours in a 5 degrees head-down bed rest model of weightlessness, and compares these responses to those obtained when subjects were positioned in head-up tilts of 10 degrees, 20 degrees, and 42 degrees, simulating 1/6, 1/3, and 2/3 G, respectively. Thoracic fluid index, cardiac output, stroke volume, and peak flow were measured using impedance cardiography. Cardiac dimensions and volumes were determined from two-dimensional guided M-mode echocardiograms in the left lateral decubitus position at 0, 2, 4, and 6 hours. Cardiovascular response to a stand test were compared before and after bed rest. The impedance values were related to tilt angle for the first 2 hours of tilt; however, after 3 hours, at all four angles, values began to converge, indicating that cardiovascular homeostatic mechanisms seek a common adapted state, regardless of effective gravity level (tilt angle) up to 2/3 G. Echocardiography revealed that left ventricular end-diastolic and end-systolic volume, stroke volume, ejection fraction, heart rate, and cardiac output had returned to control values by hour 6 for all tilt angles. The lack of a significant immediate change in left ventricular end-diastolic volume, despite decrements in stroke volume (P < .05) and heart rate (not significant), indicates that multiple factors may play a role in the adaptation to simulated hypogravity. The echocardiography data indicated that no angle of tilt, whether head-down or head-up for 4 to 6 hours, mimicked exactly the changes in cardiovascular function recorded after 4 to 6 hours of space flight. Changes in left ventricular end-diastolic volume during space flight and tilt may be similar, but follow a different time course. Nevertheless, head-down tilt at 5 degrees for 6 hours mimics some (stroke volume, systolic and diastolic blood pressure, mean arterial blood pressure, and total resistance), but not all, of the changes occurring in an equivalent time of space flight. The magnitude of the change in the mean heart rate response to standing was greater after six hours of tilt at -5 degrees or 10 degrees. Thus, results from the stand test after 6 hours of bed rest at -5 degrees and 10 degrees, but not at 20 degrees or 42 degrees, are similar to those obtained after space flight.

Space Flight↗

Cardiovascular responses to repetitive exposure to hyper- and hypogravity states produced by parabolic flight

Physiologic changes to repetitive hyper- and hypogravity stresses occurring during eight to ten parabolas on NASA's KC-135 aircraft were studied. Hemodynamic responses in 11 subjects in 4 different postures (supine, standing, sitting, and semisupine Space Shuttle launch position) were determined using noninvasive impedance cardiography. Five seconds of heart rate, cardiac index, thoracic fluid index, stroke index, ejection velocity index, and ventricular ejection time data were averaged during four different gravity (g) states: 1.3g (before parabola onset); 1.9g (parabola entry); 0g (parabola peak); and 1.7g (parabola exit) for each subject. The standing position was associated with the largest changes in the cardiovascular response to hypo- and hypergravity. The thoracic fluid index did not indicate a headward redistribution during transition from a simulated launch position to weightlessness. Analysis of the eight to ten parabolas revealed that, in general, values obtained at 1.8g differed from 1.6g, 0g differed from 1.6 and 1.3g, and 1.6g differed from 1.3g. The factors of gravity, thoracic fluid index, and cardiac index exhibited significant differences that were most likely to occur between parabola 1 versus parabolas 6, 7, and 8, and parabola 2 versus parabolas 4 through 8. Only the parameter of thoracic fluid index exhibited significance for parabolas 3 versus parabolas 6 and 7.

Space Flight↗

Orthostatic hypotension in patients, bed rest subjects, and astronauts

Orthostatic hypotension after even short space flights has affected a significant number of astronauts. Given the need for astronauts to function at a high level of efficiency during and after their return from space, the application of pharmacologic and other treatments is strongly indicated. This report addresses the clinical problem of orthostatic hypotension and its treatments to ascertain whether pharmacologic or physiologic treatment may be useful in the prevention of orthostatic hypotension associated with space flight. Treatment of orthostatic hypotension in patients now includes increasing intravascular volume with high sodium intake and mineralocorticoids, or increasing vascular resistance through the use of drugs to stimulate alpha or block beta vascular receptors. Earlier treatment used oral sympathomimetic ephedrine hydrochloride alone or with "head-up" bed rest. Then long-acting adrenocortical steroid desoxycorticosterone preparations with high-salt diets were used to expand volume. Fludrocortisone was shown to prevent the orthostatic drop in blood pressure. The combination of the sympathomimetic amine hydroxyamphetamine and a monoamine oxidase inhibitor tranylcypromine has been used, as has indomethacin alone. Davies et al. used mineralocorticoids at low doses concomitantly with alpha-agonists to increase vasoconstrictor action. Schirger et al used tranylcypromine and methylphenidate with or without a Jobst elastic leotard garment or the alpha-adrenergic agonist midodrine (which stimulates both arterial and venous systems without direct central nervous system or cardiac effects). Vernikos et al established that the combination of fludrocortisone, dextroamphetamine, and atropine exhibited a beneficial effect on orthostatic hypotension induced by 7-day 6 degrees head-down bed rest (a model used to simulate the weightlessness of space flight). Thus, there are numerous drugs that, in combination with mechanical techniques, including lower body negative pressure to elevate transmural pressure, could be studied to treat orthostatic hypotension after space flight.

Review↗

A comprehensive Guyton model analysis of physiologic responses to preadapting the blood volume as a countermeasure to fluid shifts

The Guyton model of fluid, electrolyte, and circulatory regulation is an extensive mathematical model capable of simulating a variety of experimental conditions. It has been modified for use at NASA to simulate head-down tilt, a frequently used analog of weightlessness. Weightlessness causes a headward shift of body fluids that is believed to expand central blood volume, triggering a series of physiologic responses resulting in large losses of body fluids. We used the modified Guyton model to test the hypothesis that preadaptation of the blood volume before weightless exposure could counteract the central volume expansion caused by fluid shifts, and thereby attenuate the circulatory and renal responses that result in body fluid losses. Simulation results show that circulatory preadaptation, by a procedure resembling blood donation immediately before head-down bedrest, is effective in damping the physiologic responses to fluid shifts and reducing body fluid losses. After 10 hours of head-down tilt, preadaptation also produces higher blood volume, extracellular volume, and total body water for 20 to 30 days of bedrest, compared with non-preadapted control. These results indicate that circulatory preadaptation before current Space Shuttle missions may be beneficial for the maintenance of reentry and postflight orthostatic tolerance in astronauts. This paper presents a comprehensive examination of the simulation results pertaining to changes in relevant physiologic variables produced by blood volume reduction before a prolonged head-down tilt. The objectives were to study and develop the countermeasure theoretically, to aid in planning experimental studies of the countermeasure, and to identify potentially disadvantageous physiologic responses that may be caused by the countermeasure.

NASA Center JSC↗

Use of lower body negative pressure to counter symptoms of orthostatic intolerance in patients, bed rest subjects, and astronauts

This report briefly discusses some aspects of autonomic cardiovascular dysfunction as related to changes in orthostatic function in patients, bed rest subjects, and astronauts. This relationship is described in normal individuals to provide the basis for discussion of parameters that may be altered in patients, bed rest subjects, and astronauts. The relationships between disease states, age, periods of weightlessness during space flight, and autonomic dysfunction, and their contribution to changes in orthostatic tolerance are presented. The physiologic effects of lower body negative pressure are illustrated by presenting data obtained in bed rest subjects and in astronauts. Finally, the usefulness of lower body negative pressure to counter symptoms of orthostatic intolerance in patients, bed rest subjects, and astronauts is discussed.

Review, Tutorial↗

Echocardiograms during six hours of bedrest at head-down and head-up tilt and during space flight

Left ventricular end-diastolic volume increased after 4 1/2 to 6 hours of space flight, but was significantly decreased after 5 to 6 days of space flight. To determine the role of acute gravitational effects in this phenomenon, responses to a 6-hour bedrest model of 0 gravity (G; 5 degrees head-down tilt) were compared with those of fractional gravity loads of 1/6 G, 1/3 G, and 2/3 G by using head-up tilts of 10 degrees, 20 degrees, and 42 degrees, respectively. On 4 different days, six healthy male subjects were tilted at one of the four angles for 6 hours. Cardiac dimensions and volumes were determined from two-dimensional and M-mode echocardiograms in the left lateral decubitus position at control (0), 2, 4, and 6 hours. Stroke volume decreased with time (P < .05) for all tilt angles when compared with control. Ejection fraction (EF) at -5 degrees was greater than at +20 degrees and +42 degrees (not significant); EF at +10 degrees was greater than at +42 degrees (not significant). For the tilt angles of -5 degrees, +10 degrees, and +20 degrees, mean heart rate decreased during the first 2 hours, and returned to control or was slightly elevated above control (+20 degrees) by 6 hours (not significant). At the +42 degrees angle of tilt, heart rate was increased above control at hours 2, 4, and 6. There were no significant differences in cardiac output at any time point for any tilt angle.(ABSTRACT TRUNCATED AT 250 WORDS).

Flight Experiment↗

Mathematical modelling of the human cardiovascular system in the presence of stenosis

This paper reports a theoretical study on the distribution of blood flow in the human cardiovascular system when one or more blood vessels are affected by stenosis. The analysis employs a mathematical model of the entire system based on the finite element method. The arterial-venous network is represented by a large number of interconnected segments in the model. Values for the model parameters are based upon the published data on the physiological and rheological properties of blood. Computational results show how blood flow through various parts of the cardiovascular system is affected by stenosis in different blood vessels. No significant changes in the flow parameters of the cardiovascular system were found to occur when the reduction in the lumen diameter of the stenosed vessels was less than 65%.

NASA Program Data Analysis↗

Physiologic mechanisms of circulatory and body fluid losses in weightlessness identified by mathematical modeling

Central volume expansion due to fluid shifts in weightlessness is believed to activate adaptive reflexes which ultimately result in a reduction of the total circulating blood volume. However, the flight data suggests that a central volume overdistention does not persist, in which case some other factor or factors must be responsible for body fluid losses. We used a computer simulation to test the hypothesis that factors other than central volume overdistention are involved in the loss of blood volume and other body fluid volumes observed in weightlessness and in weightless simulations. Additionally, the simulation was used to identify these factors. The results predict that atrial volumes and pressures return to their prebedrest baseline values within the first day of exposure to head down tilt (HDT) as the blood volume is reduced by an elevated urine formation. They indicate that the mechanisms for large and prolonged body fluid losses in weightlessness is red cell hemoconcentration that elevates blood viscosity and peripheral resistance, thereby lowering capillary pressure. This causes a prolonged alteration of the balance of Starling forces, depressing the extracellular fluid volume until the hematocrit is returned to normal through a reduction of the red cell mass, which also allows some restoration of the plasma volume. We conclude that the red cell mass becomes the physiologic driver for a large 'undershoot' of the body fluid volumes after the normalization of atrial volumes and pressures.

Simanonok, K. E.↗

Venous compliance and fluid shift measurements on Spacelab IML-1

During the first few hours of a human spaceflight mission, a headward fluid shift out of the abdomen, pelvis, and legs initiates a number of adaptive cardiovascular responses, including a loss of intravascular and extravascular fluid volume. On return to earth, these cardiovascular changes may lead to debilitating symptoms of orthostatic intolerance in an unprotected astronaut. To test the hypothesis that an inflight increase in compliance of the leg veins may contribute to this condition, measurements of lower leg fluid shift and bulk venous compliance were collected from crew members during the eight-day First International Microgravity Laboratory shuttle mission. An ultrasonic limb plethysmograph, in conjunction with two compression cuffs encircling the calf and thigh, was used to determine bulk compliance of the underlying veins over a range of negative and positive transmural pressures. The data from inflight experiment sessions were compared to preflight and postflight sessions. The preliminary results indicate that the volume of the lower leg decreased by over 10 percent by the sixth day of flight, but there was no apparent change in venous compliance.

Leiski, D.↗

Mathematical modeling of human cardiovascular system for simulation of orthostatic response

This paper deals with the short-term response of the human cardiovascular system to orthostatic stresses in the context of developing a mathematical model of the overall system. It discusses the physiological issues involved and how these issues have been handled in published cardiovascular models for simulation of orthostatic response. Most of the models are stimulus specific with no demonstrated capability for simulating the responses to orthostatic stimuli of different types. A comprehensive model incorporating all known phenomena related to cardiovascular regulation would greatly help to interpret the various orthostatic responses of the system in a consistent manner and to understand the interactions among its elements. This paper provides a framework for future efforts in mathematical modeling of the entire cardiovascular system.

NASA Discipline Cardiopulmonary↗

The effects of exercise on blood flow with reference to the human cardiovascular system: a finite element study

This paper reports on a theoretical investigation into the effects of vasomotion on blood through the human cardiovascular system. The finite element method has been used to analyse the model. Vasoconstriction and vasodilation may be effected either through the action of the central nervous system or autoregulation. One of the conditions responsible for vasomotion is exercise. The proposed model has been solved and quantitative results of flows and pressures due to changing the conductances of specific networks of arterioles, capillaries and venules comprising the arms, legs, stomach and their combinations have been obtained.

NASA Discipline Cardiopulmonary↗

Mathematical modelling of flow distribution in the human cardiovascular system

The paper presents a detailed model of the entire human cardiovascular system which aims to study the changes in flow distribution caused by external stimuli, changes in internal parameters, or other factors. The arterial-venous network is represented by 325 interconnected elastic segments. The mathematical description of each segment is based on equations of hydrodynamics and those of stress/strain relationships in elastic materials. Appropriate input functions provide for the pumping of blood by the heart through the system. The analysis employs the finite-element technique which can accommodate any prescribed boundary conditions. Values of model parameters are from available data on physical and rheological properties of blood and blood vessels. As a representative example, simulation results on changes in flow distribution with changes in the elastic properties of blood vessels are discussed. They indicate that the errors in the calculated overall flow rates are not significant even in the extreme case of arteries and veins behaving as rigid tubes.

NASA Center JSC↗

Space sickness predictors suggest fluid shift involvement and possible countermeasures

Preflight data from 64 first time Shuttle crew members were examined retrospectively to predict space sickness severity (NONE, MILD, MODERATE, or SEVERE) by discriminant analysis. From 9 input variables relating to fluid, electrolyte, and cardiovascular status, 8 variables were chosen by discriminant analysis that correctly predicted space sickness severity with 59 pct. success by one method of cross validation on the original sample and 67 pct. by another method. The 8 variables in order of their importance for predicting space sickness severity are sitting systolic blood pressure, serum uric acid, calculated blood volume, serum phosphate, urine osmolality, environmental temperature at the launch site, red cell count, and serum chloride. These results suggest the presence of predisposing physiologic factors to space sickness that implicate a fluid shift etiology. Addition of a 10th input variable, hours spent in the Weightless Environment Training Facility (WETF), improved the prediction of space sickness severity to 66 pct. success by the first method of cross validation on the original sample and to 71 pct. by the second method. The data suggest that WETF training may reduce space sickness severity.

Simanonok, K. E.↗

Computer simulation of preflight blood volume reduction as a countermeasure to fluid shifts in space flight

Fluid shifts in weightlessness may cause a central volume expansion, activating reflexes to reduce the blood volume. Computer simulation was used to test the hypothesis that preadaptation of the blood volume prior to exposure to weightlessness could counteract the central volume expansion due to fluid shifts and thereby attenuate the circulatory and renal responses resulting in large losses of fluid from body water compartments. The Guyton Model of Fluid, Electrolyte, and Circulatory Regulation was modified to simulate the six degree head down tilt that is frequently use as an experimental analog of weightlessness in bedrest studies. Simulation results show that preadaptation of the blood volume by a procedure resembling a blood donation immediately before head down bedrest is beneficial in damping the physiologic responses to fluid shifts and reducing body fluid losses. After ten hours of head down tilt, blood volume after preadaptation is higher than control for 20 to 30 days of bedrest. Preadaptation also produces potentially beneficial higher extracellular volume and total body water for 20 to 30 days of bedrest.

Simanonok, K. E.↗

Computer simulation analysis of the effects of countermeasures for reentry orthostatic intolerance

Fluid loading is a countermeasure currently in routine use to improve the g-tolerance of crewmembers during reentry and return of Shuttle flights. However, its effectiveness diminishes with mission duration. Countermeasures that will be effective on long-duration flights are needed and are presently under development. This paper discusses the application of computer simulation in the analysis of the effects of countermeasures for reentry orthostatic intolerance. The results suggest improvements upon the fluid loading countermeasure currently in use.

NASA Center JSC↗

Cardiovascular function in space flight

Changes in orthostatic heart rate have been noted universally in Soviet and U.S. crewmembers post space flight. The magnitude of these changes appears to be influenced by mission duration, with increasing orthostatic intolerance for the first 7-10 days of flight and then a partial recovery in the orthostatic heart rate response. Fluid loading has been used as a countermeasure to this postflight orthostatic intolerance. Previous reports have documented the effectiveness of this technique, but it has also been noted that the effectiveness of volume expansion diminishes as flight duration exceeds one week. The response of carotid baroreceptor function was investigated utilizing a commercially available neck collar which could apply positive and negative pressure to effect receptor stimulation. Bedrest studies had validated the usefulness and validity of the device. In these studies it was shown that carotid baroreceptor function curves demonstrated less responsiveness to orthostatic stimulation than control individuals. Twelve Space Shuttle crewmembers were examined pre- and postflight from flights lasting from 4-5 days. Plots of baroreceptor function were constructed and plotted as change in R-R interval vs. carotid distending pressure (an orthostatic stimulus). Typical sigmoidal curves were obtained. Postflight the resting heart rate was higher (smaller R-R interval) and the range of R-R value and the slope of the carotid sigmoidal response were both depressed. These changes were not significant immediately postflight (L + O), but did become significant by the second day postflight (L + 2), and remained suppressed for several days thereafter. It is hypothesized that the early adaptation to space flight involves a central fluid shift during the initial days of flight, but subsequent alterations in neural controlling mechanisms (such as carotid baroreceptor function) contribute to orthostatic intolerance.

Review↗