Engineering Papers⌕ Search

Engineering topics

Chao, Wang

Publications and source records attributed to Chao, Wang.

Graphene sheets embedded carbon film prepared by electron irradiation in electron cyclotron resonance plasma

We used a low energy electron irradiation technique to prepare graphene sheets embedded carbon (GSEC) film based on electron cyclotron resonance plasma. The particular {pi} electronic structure of the GSEC film similar to bilayer graphene was verified by Raman spectra 2D band analyzing. The phase transition from amorphous carbon to GSEC was initiated when electron irradiation energy reached 40 eV, and the growth mechanism of GSEC was interpreted as inelastic scattering of low energy electrons. This finding indicates that the GSEC film obtained by low energy electron irradiation can be excepted for widely applications with outstanding electric properties.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparing Radiation Treatments Using Intensity-Modulated Beams, Multiple Arcs, and Single Arcs

Purpose: A dosimetric comparison of multiple static-field intensity-modulated radiation therapy (IMRT), multiarc intensity-modulated arc therapy (IMAT), and single-arc arc-modulated radiation therapy (AMRT) was performed to evaluate their clinical advantages and shortcomings. Methods and Materials: Twelve cases were selected for this study, including three head-and-neck, three brain, three lung, and three prostate cases. An IMRT, IMAT, and AMRT plan was generated for each of the cases, with clinically relevant planning constraints. For a fair comparison, the same parameters were used for the IMRT, IMAT, and AMRT planning for each patient. Results: Multiarc IMAT provided the best plan quality, while single-arc AMRT achieved dose distributions comparable to those of IMRT, especially in the complicated head-and-neck and brain cases. Both AMRT and IMAT showed effective normal tissue sparing without compromising target coverage and delivered a lower total dose to the surrounding normal tissues in some cases. Conclusions: IMAT provides the most uniform and conformal dose distributions, especially for the cases with large and complex targets, but with a delivery time similar to that of IMRT; whereas AMRT achieves results comparable to IMRT with significantly faster treatment delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Two tri-spin complexes based on gadolinium and nitronyl nitroxide radicals: Structure and ferromagnetic interactions

Three Radical-Ln(III)-Radical complexes based on nitronyl nitroxide radicals have been synthesized, structurally and magnetically characterized: [Gd(hfac){sub 3}(NITPhOEt){sub 2}] (1) (hfac=hexafluoroacetylacetonate, and NITPhOEt=4'-ethoxy-phenyl-4,4,5,5-tetramethylimidazoline-1-oxyl-3-oxide), [Gd(hfac){sub 3}(NITPhOCH{sub 2}Ph){sub 2}] (2) (NITPhOCH{sub 2}Ph=4'-benzyloxy-phenyl-4,4,5, 5-tetramethylimidazoline-1-oxyl-3-oxide) and [Lu(hfac){sub 3}(NITPhOCH{sub 2}Ph){sub 2}] (3). The X-ray crystal structure analyses show that the structures of the three compounds are similar and all consist of the isolated molecules, in which central ions Gd{sup III} or Lu{sup III} are coordinated by six oxygen atoms from three hfac and two oxygen atoms from nitronyl radicals. The magnetic studies show that in both of the two Gd{sup III} complexes, there are ferromagnetic Gd{sup III}-Rad interactions and antiferro-magnetic Rad-Rad interactions in the molecules (with J{sub Rad-Gd}=0.27 cm{sup -1}, j{sub Rad-Rad}=-2.97 cm{sup -1} for 1: and J{sub Rad-Gd}=0.62 cm{sup -1}, j{sub Rad-Rad}=-7.01 cm{sup -1} for 2). An analogous complex of [Lu(hfac){sub 3} (NITPhOCH{sub 2}Ph){sub 2}] (3) containing diamagnetic Lu{sup III} ions has also been introduced for further demonstrating the nature of magnetic coupling between radicals. - Graphical abstract: Two tri-spin complexes based on gadolinium-radical have been synthesized and characterized, the magnetic studies show that in the two complexes the Gd-radical interaction is ferromagnetic and the radical-radical interaction is antiferromagnetic. An analogous complex containing the diamagnetic Lu{sup III} ions has also been synthesized to further demonstrate the nature of the magnetic coupling between radicals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-resolution reflecting time-of-flight momentum and energy mapping system

A new system to map electron momentum and energy is proposed. A reflecting electrode is introduced into a time-of-flight (TOF) system whose decelerating electric field sends all the electrons back to a position-sensitive detector close to but behind the source of the electrons. The longer flying distance that results makes it possible to significantly improve the energy-resolved performance, especially in the higher energy region. The dependence of the new TOF system on its characteristic parameters is analyzed, along with its application to attosecond streak cameras. Experimental results verified a relative energy resolution better than 0.2 eV for 22 eV electrons and also revealed the availability of the improved relative energy resolution smaller than 1.0% for electron energy ranging from 30 to 40 eV.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Leaf-sequencing for intensity-modulated arc therapy using graph algorithms

Intensity-modulated arc therapy (IMAT) is a rotational IMRT technique. It uses a set of overlapping or nonoverlapping arcs to create a prescribed dose distribution. Despite its numerous advantages, IMAT has not gained widespread clinical applications. This is mainly due to the lack of an effective IMAT leaf-sequencing algorithm that can convert the optimized intensity patterns for all beam directions into IMAT treatment arcs. To address this problem, we have developed an IMAT leaf-sequencing algorithm and software using graph algorithms in computer science. The input to our leaf-sequencing software includes (1) a set of (continuous) intensity patterns optimized by a treatment planning system at a sequence of equally spaced beam angles (typically 10 deg. apart), (2) a maximum leaf motion constraint, and (3) the number of desired arcs, k. The output is a set of treatment arcs that best approximates the set of optimized intensity patterns at all beam angles with guaranteed smooth delivery without violating the maximum leaf motion constraint. The new algorithm consists of the following key steps. First, the optimized intensity patterns are segmented into intensity profiles that are aligned with individual MLC leaf pairs. Then each intensity profile is segmented into k MLC leaf openings using a k-link shortest path algorithm. The leaf openings for all beam angles are subsequently connected together to form 1D IMAT arcs under the maximum leaf motion constraint using a shortest path algorithm. Finally, the 1D IMAT arcs are combined to form IMAT treatment arcs of MLC apertures. The performance of the implemented leaf-sequencing software has been tested for four treatment sites (prostate, breast, head and neck, and lung). In all cases, our leaf-sequencing algorithm produces efficient and highly conformal IMAT plans that rival their counterpart, the tomotherapy plans, and significantly improve the IMRT plans. Algorithm execution times ranging from a few seconds to 2 min are observed on a laptop computer equipped with a 2.0 GHz Pentium M processor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗