Engineering Papers⌕ Search

Engineering topics

Carroll, Kenneth C.

Publications and source records attributed to Carroll, Kenneth C..

25 records · Page 2

Development of a coupled thermo-hydro-mechanical model in discontinuous media for carbon sequestration

Geomechanical alteration of porous media is generally ignored for most shallow subsurface applications, whereas CO 2 injection, migration, and trapping in deep saline aquifers will be controlled by coupled multifluid flow, energy transfer, and geomechanical processes. The accurate assessment of the risks associated with potential leakage of injected CO 2 and the design of effective injection systems requires that we represent these coupled processes within numerical simulators. The objectives of this study were to develop a coupled thermal-hydro-mechanical model into a single software, and to examine the coupling of thermal, hydrological, and geomechanical processes for simulation of CO 2 injection into the subsurface for carbon sequestration. A numerical model is developed to couple nonisothermal multiphase hydrological and geomechanical processes for prediction of multiple interconnected processes for carbon sequestration in deep saline aquifers. The geomechanics model was based on Rigid Body-Spring Model (RBSM), one of the discrete methods to model discontinuous rock system. Poisson’s effect that was often ignored by RBSM was considered in the model. The simulation of large-scale and long-term coupled processes in carbon capture and storage projects requires large memory and computational performance. Global Array Toolkit was used to build the model to permit the high performance simulations of the coupled processes. The model was used to simulate a case study with several scenarios to demonstrate the impacts of considering coupled processes and Poisson’s effect for the prediction of CO 2 sequestration.

54 ENVIRONMENTAL SCIENCES↗

Characterization of Persistent Volatile Contaminant Sources in the Vadose Zone

Remediation activities over time will alter the subsurface distribution of contaminants and likely create significant changes in the source-zone architecture. A field method was demonstrated for use of data collected from multiple individual soil vapor extraction (SVE) system well tests to locate and characterize the distribution of persistent VOC sources in the vadose zone. Operational data collected at the Department of Energy’s Hanford site were used to examine source zone alteration over time due to SVE operation and to illustrate the source-zone characterization approach. Individual well test results confirmed a heterogeneous distribution of permeability and contaminant mass discharge throughout the vadose zone. The trends in mass discharge and concentration were analyzed to determine the location and extent of the primary source zone within a lower-permeability unit at the site. This information is useful to evaluate the performance of SVE operations, and support decisions concerning system alteration or closure based on risk assessments of the impact of vadose-zone sources on groundwater contamination or vapor intrusion.

carbon tetrachloride↗

Remedy Evaluation Framework for Inorganic, Non-Volatile Contaminants in the Vadose Zone

Contaminants in the vadose zone may act as a potential long-term source of groundwater contamination and need to be considered in remedy evaluations. In many cases, remediation decisions for the vadose zone will need to be made all or in part based on projected impacts to groundwater. Because there are significant natural attenuation processes inherent in vadose zone contaminant transport, remediation in the vadose zone to protect groundwater is functionally a combination of natural attenuation and use of other remediation techniques, as needed, to mitigate contaminant flux to groundwater. Attenuation processes include both hydrobiogeochemical processes that serve to retain contaminants within porous media and physical processes that mitigate the rate of water flux. In particular, the physical processes controlling fluid flow in the vadose zone are quite different and generally have a more significant attenuation impact on contaminant transport relative to those within the groundwater system. A remedy evaluation framework is presented herein that uses an adaptation of the established EPA Monitored Natural Attenuation (MNA) evaluation approach and a conceptual model based approach focused on identifying and quantifying features and processes that control contaminant flux through the vadose zone. A key concept for this framework is to recognize that MNA will comprise some portion of all remedies in the vadose zone. Thus, structuring evaluation of vadose zone waste sites to use an MNA-based approach provides information necessary to either select MNA as the remedy, if appropriate, or to quantify how much additional attenuation would need to be induced by a remedial action (e.g., technologies considered in a feasibility study) to augment the natural attenuation processes and meet groundwater protection goals.

natural attenuation↗

Integrated Systems-Based Approach to Monitoring Environmental Remediation

The US Department of Energy (DOE) is responsible for risk reduction and cleanup of its nuclear weapons complex. Remediation strategies for some of the existing contamination use techniques that mitigate risk, but leave contaminants in place. Monitoring to verify remedy performance and long-term mitigation of risk is a key element for implementing these strategies and can be a large portion of the total cost of remedy implementation. Especially in these situations, there is a need for innovative monitoring approaches that move away from the cost and labor intensive point-source monitoring. A systems-based approach to monitoring design focuses monitoring on controlling features and processes to enable effective interpretation of remedy performance.

environmental remediation↗

Characterization and Remediation of Chlorinated Volatile Organic Contaminants in the Vadose Zone

Contamination of vadose-zone systems by chlorinated solvents is widespread, and poses significant potential risk to human health through impacts on groundwater quality and vapor intrusion. Soil vapor extraction (SVE) is the presumptive remedy for such contamination, and has been used successfully for innumerable sites. However, SVE operations typically exhibit reduced mass-removal effectiveness at some point due to the impact of poorly accessible contaminant mass and associated mass-transfer limitations. Assessment of SVE performance and closure is currently based on characterizing contaminant mass discharge associated with the vadose-zone source, and its impact on groundwater or vapor intrusion. These issues are addressed in this overview, with a focus on summarizing recent advances in our understanding of the transport, characterization, and remediation of chlorinated solvents in the vadose zone. The evolution of contaminant distribution over time and the associated impacts on remediation efficiency will be discussed, as will the potential impact of persistent sources on groundwater quality and vapor intrusion. In addition, alternative methods for site characterization and remediation will be addressed.

Brusseau, Mark L.↗

Treatability Test Report: Characterization of Vadose Zone Carbon Tetrachloride Source Strength Using Tomographic Methods at the 216-Z-9 Site

A treatability test was conducted in 2011 at the 216-Z-9 Trench to evaluate methods for collecting characterization information that supports refined assessment of SVE performance goals based on impact to groundwater. The characterization information can also provide input to operational strategies for continued SVE operation and decisions regarding closure of the SVE system or transition to other remedies, if necessary.

Carbon Tetrachloride↗

Assessing Soil Vapor Extraction Remediation Performance and Closure: A Review

Soil vapor extraction (SVE) is a baseline remediation approach for volatile contaminants. While SVE is generally effective for removal of contaminants from higher permeability portions of the vadose zone, contamination in low-permeability zones can persist due to mass transfer processes that limit the removal effectiveness. Thus, a diminishing rate of contaminant extraction over time is typically observed, yet contamination may remain in low-permeability zones. Under these conditions, SVE performance needs to be evaluated to determine whether the system should be optimized, terminated, or transitioned to another technology to replace or augment SVE. Methodologies have been developed to quantify SVE performance over time and to evaluate the impact of persistent vadose zone contamination sources on groundwater quality. Recently, these methods have applied mass flux/discharge concepts to quantify contaminant source strength. Methods include field measurement techniques using the SVE system to quantify source strength and predictive analyses with analytical and numerical models to evaluate the impact of the contaminant source on groundwater.

remediation↗