Engineering Papers⌕ Search

Engineering topics

Carman, April J.

Publications and source records attributed to Carman, April J..

Physicochemical Gas–Solid Sorption Properties of Geologic Materials Using Inverse Gas Chromatography

The goal of this study was to determine the physicochemical properties of a variety of geologic materials using inverse gas chromatography (IGC) by varying probe gas selection, temperature, carrier gas flow rate, and humidity. This is accomplished by measuring the level of interaction between the materials of interest and known probe gases. Identifying a material’s physicochemical characteristics can help provide a better understanding of the transport of gaseous compounds in different geologic materials or between different geological layers under various conditions. Our research in this study focused on measuring the enthalpy (heat) of adsorption, Henry’s constant, and diffusion coefficients of a suite of geologic materials, including two soil types (sandy clay-loam and loam), quartz sand, salt, and bentonite clay, with various particle sizes. The reproducibility of IGC measurements for geologic materials, which are inherently heterogeneous, was also assessed in comparison to the reproducibility for more homogeneous synthetic materials. This involved determining the variability of physicochemical measurements obtained from different IGC approaches, instruments, and researchers. For the investigated IGC-determined parameters, the need for standardization became apparent, including the need for application-relevant reference materials. The inherent physical and chemical heterogeneities of soil and many geologic materials can make the prediction of sorption properties difficult. Characterizing the properties of individual organic and inorganic components can help elucidate the primary factors influencing sorption interactions in more complex mixtures. This research examined the capabilities and potential challenges of characterizing the gas sorption properties of geologic materials using IGC.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rugged nanoparticle tracers for mass tracking in explosive events

Tracing the flow of solid matter during an explosion requires a rugged tag that can be measured by a unique identifiable signature. Silica-covered semiconductor quantum dots (QDs) provide a unique and tunable photoluminescent signature that emits from within a sacrificial outer layer. Five types of silica-covered zinc sulfide QDs were synthesized and covalently bound to commercial luminescent powders. The combination of five dots and five powders enables a matrix of 25 unique tags. The tracers are shown to be tolerant of environments associated with chemical explosives and provides a unique tag to evaluate debris fields.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Enhanced Ion Detection for Atomic Mass Spectrometry

In atomic mass spectrometry, polyatomic interferences that obscure ions of interest are a serious concern and in many cases hamper, or make impossible, the measurement of low signal analytes. Electron multipliers in pulse counting mode are used prolifically when low intensity ion beams are present during analysis as they provide on the order of 106-107 signal amplification, however simply counting the number of electron pulses ignores differences in the impact physics that are present depending on ion identity. The objective of this research was to investigate the efficacy of utilizing advanced neural network analysis and machine learning to recognize the differences in the analog electron multiplier pulse shapes for atomic vs. polyatomic ions of similar or identical mass as a means of distinguishing the two ion types. In this work, we’ve successfully discriminated polyatomic interferants from atomic analytes of interest for two different mass spectrometers, and three different ion pairs; Krypton isotope/hydride and methane/oxygen (noble gas mass spectrometer) and 129I atomic vs 129I polyatomic (Triton mass spectrometer). Discrimination accuracy for these experiments ranged from 76% to 95%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulating the effects of underground nuclear explosions with an exploding wire

Exploding wires can deposit significant amounts of energy (1000’s of Joules on a nano-microsecond timescales) into a very confined space. Under the right conditions they can even produce neutrons. While most exploding wire studies have been performed in open air and to a lesser extent liquids we have started to investigate enclosing the wire element in solid matrices like concrete to mimic the effects of an underground nuclear explosion. The temperatures and pressures achieved are quite sufficient to induce structural cracking and localized flash melting in the enclosing media like a real underground nuclear detonation. As a result exploding wires would appear to form the perfect trigger for releasing confined chemical species including gases in geological media to study migration behavior in a controlled environment. Details of the apparatus and some illustrations of it potential will be given.

Underground Nuclear Explosions, Exploding Wires, X↗

The Preparation of Non-radioactive Glassy Surrogate Nuclear Explosion Debris (SNED) Loaded with an Isotopically Altered Noble Gas

The measurement of the Kr and Xe isotope ratios in nuclear explosion debris is an important forensic tool as the method requires very little sample preparation. Fragments of debris are simply crushed or heated to release the trapped gases Kr and Xe arising from fission product decay. As suitable test materials are not readily available we have been investigating a method to incorporate isotopically enriched 129Xe in glassy materials that mimic nuclear explosion debris. The approach used to prepare these materials will be described along with some of the example results obtained.

Trinitite, Nuclear forensics, Fission Xe, Surrogat↗

Source Attribution of Cyanides using Anionic Impurity Profiling, Stable Isotope Ratios, Trace Elemental Analysis and Chemometrics

Chemical attribution signatures (CAS) for chemical threat agents (CTAs) are being investigated to provide an evidentiary link between CTAs and specific sources to support criminal investigations and prosecutions. In a previous study, anionic impurity profiles developed using high performance ion chromatography (HPIC) were demonstrated as CAS for matching samples from eight potassium cyanide (KCN) stocks to their reported countries of origin. Herein, a larger number of solid KCN stocks (n = 13) and, for the first time, solid sodium cyanide (NaCN) stocks (n = 15) were examined to determine what additional sourcing information can be obtained through anion, carbon stable isotope, and elemental analyses of cyanide stocks by HPIC, isotope ratio mass spectrometry (IRMS), and inductively coupled plasma optical emission spectroscopy (ICP-OES), respectively. The HPIC anion data was evaluated using the variable selection methods of Fisher-ratio (F-ratio), interval partial least squares (iPLS), and genetic algorithm-based partial least squares (GAPLS) and the classification methods of partial least squares discriminate analysis (PLSDA), K nearest neighbors (KNN), and support vector machines discriminate analysis (SVMDA). In summary, hierarchical cluster analysis (HCA) of anion impurity profiles from multiple cyanide stocks from six reported country of origins resulted in cyanide samples clustering into three groups: Czech Republic, Germany, and United States, independent of the associated alkali metal (K or Na). The three country groups were independently corroborated by HCA of cyanide elemental profiles and corresponded to countries with known solid cyanide factories. Both the anion and elemental CAS are believed to originate from the aqueous alkali hydroxides used in cyanide manufacture. Carbon stable isotope measurements resulted in two clusters: Germany and United States (the single Czech stock grouped with United States stocks). The carbon isotope CAS is believed to originate from the carbon source and process used to make the HCN utilized in cyanide synthesis. Classification errors for two validation studies using anion impurity profiles collected over five years on different instruments were as low as zero for KNN and SVMDA, demonstrating the excellent reliability (so far) of using anion impurities for matching a cyanide sample to its country of manufacture (i.e., factory). Variable selection reduced errors for those classification methods having errors greater than zero with iPLS-forward selection, and F-ratio typically providing the lowest errors. Finally, using anion profiles to match cyanides to a specific stock or stock group resulted in cross-validation errors ranging from zero to 5.3%.

chemical forensics↗

Feasibility of a Fieldable Mass Spectrometer FY 2015 Year-end Report

Currently, the International Atomic Energy Agency (IAEA) monitors the production of enriched uranium hexafluoride (UF 6 ) at declared facilities by collecting a few grams of product in sample tubes that are then sent to central laboratories for processing and isotope ratio analysis by thermal ionization mass spectrometry. Analysis of results may not be available for some time after collection. In addition, new shipping regulations will make it more difficult to transport this amount of UF 6 to a laboratory. The IAEA is interested in an isotope ratio technique for uranium in UF 6 that can be moved to and operated at the enrichment facility itself. This report covers the tasks and activities of the Feasibility of a Fieldable Mass Spectrometer Project for FY 2015, which investigates the feasibility of an in-field isotope ratio technique— the forward deployment of a technique to the non-laboratory situation of a protected room with power and heat at the facility of interest. A variety of nontraditional elemental ionization techniques were considered. It was determined that only two of these should be moved forward for testing with the candidate in-field mass spectrometer and with the adsorbed UF 6 sample types.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High Precision Isotopic Analysis of Actinide Bearing Materials: Performance of a New Generation of Purpose Built Actinide Multi-Collector ICPMS Instruments

Recently, a new class of multi-collector inductively coupled plasma mass spectrometers (MC-ICPMS) has been introduced commercially that includes detector arrays purpose built for actinide measurements. These detector arrays significantly enhance the data quality possible for applications encountered in nuclear forensics. Two such instruments are described in this paper, the NeptunePlusTM, developed by Thermo-Fisher (Bremen, Germany), and the NuPlasma2, developed by Nu Instruments (Wrexham, UK). Research results are presented that have been obtained by the authors using the first commercial NeptunePlusTM. This paper also presents performance characteristics and results for traditional liquid introduction, including a means for ultra-trace detection via electrochemical separation prior to solution nebulization, as well as solid sample introduction with femtosecond-laser ablation. We also discuss the advantages and limitations of the current systems for detection of the transient signals associated with these two methods for introducing sample into the plasma.

electrochemical separation↗

ICP-MS Workshop

This is a short document that explains the materials that will be transmitted to LLNL and DNN HQ regarding the ICP-MS Workshop held at PNNL June 17-19th. The goal of the information is to pass on to LLNL information regarding the planning and preparations for the Workshop at PNNL in preparation of the SIMS workshop at LLNL.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗