Engineering Papers⌕ Search

Engineering topics

Carlson, Matthew

Publications and source records attributed to Carlson, Matthew.

Integrated Thermal Energy Storage and Brayton Cycle Equipment Demonstration (Integrated TESTBED) Project Design Basis

The Integrated Thermal Energy Storage and Brayton cycle Equipment Demonstration (Integrated TESTBED) project seeks to retire commercial-scale risks associated with the design, integration,and operation of a supercritical carbon dioxide (sCO2) power cycle and concentrating solar power (CSP) thermal energy storage (TES) system. This requires an understanding of commercial-scale collector system transient impacts on the TES system, the dynamics of heat exchange from theTES to the power cycle, and the control and operation of the power cycle to accommodate various dispatch strategies. In order to retire these risks, Heliogen has proposed to construct a 5 MWe CSP demonstration facility based on directly heated particle and sCO2 technology. The receivers, primary heat exchanger, and power cycle will be deployed at a full commercial scale based on Heliogen’s modular plant architecture to ensure actual system integration risks are validated during design, construction, and operation. This work summarizes the design basis for the Integrated TESTBED project demonstration facility including a design target for capacity factor to support test operations, hours of storage, particle silo arrangement, centrifugal article receivers, a diffusion bonded particle-sCO2 heat exchanger, and a 5 MWe (net) integrally geared sCO2 recompression Brayton cycle.

14 SOLAR ENERGY↗

Design of Modular Test Facility for Particle/sCO2 Heat Exchanger Evaluation

Heliogen has designed a 1.3 MW particle and supercritical carbon dioxide (sCO2) test loop to retire technical and manufacturing risks. The data from this facility will be used to validate near commercial-scale particle heat exchanger modules. The heat exchanger is scaled to capture all features of the full-scale modules. Testing will be conducted with CARBOBEAD HSP 16/30, a larger particle size than other recent testing. The system was designed to ASME codes with the constraint that sCO2 piping and other major components are stainless steels.

14 SOLAR ENERGY↗

sCO2 heat exchanger control software

SAND2022-6992 O The sCO2 Heat Exchanger Control Software was written for control and operation of high temperature, high pressure supercritical CO2 systems designed for use as heat exchangers. The software was written using the basic LabVIEW package with LabVIEW modules added to it. The software controls valves and actuators, displays data from pressure transducers and thermocouples, and is able to record data at different storage rates. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Garcia Maldonado, Luis↗

Design of a 1 MWth Supercritical Carbon Dioxide Primary Heat Exchanger Test System

A new generation of Concentrating Solar Power (CSP) technologies is under development to provide dispatchable renewable power generation and reduce the levelized cost of electricity (LCOE) to 6 cents/kWh by leveraging heat transfer fluids (HTF) capable of operation at higher temperatures and coupling with higher efficiency power conversion cycles. The U.S. Department of Energy (DOE) has funded three pathways for Generation 3 CSP (Gen3CSP) technology development to leverage solid, liquid, and gaseous HTFs to transfer heat to a supercritical carbon dioxide (sCO 2 ) Brayton cycle. Here we present the design and off-design capabilities of a 1 MWth sCO 2 test system that can provide sCO 2 coolant to the primary heat exchangers (PHX) coupling the high-temperature HTFs to the sCO 2 working fluid of the power cycle. This system will demonstrate design, performance, lifetime, and operability at a scale relevant to commercial CSP. A dense-phase high pressure canned motor pump is used to supply up to 5.3 kg/s of sCO 2 flow to the primary heat exchanger at pressures up to 250 bar and temperatures up to 715 °C with ambient air as the ultimate heat sink. Key component requirements for this system are presented in this paper.

14 SOLAR ENERGY↗

Evaluation of Alternative Designs for a High Temperature Particle-to-sCO 2 Heat Exchanger

This paper presents an evaluation of alternative particle heat-exchanger designs, including moving packed-bed and fluidized-bed designs, for high-temperature heating of a solar-driven supercritical CO 2 (sCO 2 ) Brayton power cycle. The design requirements for high pressure (=20 MPa) and high temperature (=700 °C) operation associated with sCO 2 posed several challenges requiring high-strength materials for piping and/or diffusion bonding for plates. Designs from several vendors for a 100 kW-thermal particle-to-sCO 2 heat exchanger were evaluated as part of this project. Cost, heat-transfer coefficient, structural reliability, manufacturability, parasitics and heat losses, scalability, compatibility, erosion and corrosion, transient operation, and inspection ease were considered in the evaluation. An analytic hierarchy process was used to weight and compare the criteria for the different design options. The fluidized-bed design fared the best on heat transfer coefficient, structural reliability, scalability, and inspection ease, while the moving packed-bed designs fared the best on cost, parasitics and heat losses, manufacturability, compatibility, erosion and corrosion, and transient operation. A 100 kWt shell-and-plate design was ultimately selected for construction and integration with Sandia's falling particle receiver system.

14 SOLAR ENERGY↗

Evaluation of Alternative Designs for a High Temperature Particle-to-SCO2 Heat Exchanger

This paper presents an evaluation of alternative particle heat-exchanger designs, including moving packed-bed and fluidized-bed designs, for high-temperature heating of a solar-driven supercritical CO2 (sCO2) Brayton power cycle. The design requirements for high pressure (= 20 MPa) and high temperature (= 700 degrees C) operation associated with sCO2 posed several challenges requiring high-strength materials for piping and/or diffusion bonding for plates. Designs from several vendors for a 100 kW-thermal particle-to-sCO2 heat exchanger were evaluated as part of this project. Cost, heat-transfer coefficient, structural reliability, manufacturability, parasitics and heat losses, scalability, compatibility, erosion and corrosion, transient operation, and inspection ease were considered in the evaluation. An analytical hierarchy process was used to weight and compare the criteria for the different design options. The fluidized-bed design fared the best on heat transfer coefficient, structural reliability, scalability and inspection ease, while the moving packed-bed designs fared the best on cost, parasitics and heat losses, manufacturability, compatibility, erosion and corrosion, and transient operation. A 100 kWt shell-and-plate design was ultimately selected for construction and integration with Sandia's falling particle receiver system.

14 SOLAR ENERGY↗

Multi-objective optimization of a PCHE-type intermediate heat exchanger using genetic algorithms

For the advanced nuclear reactor systems and power conversion units, it is important to optimize the design of intermediate heat exchangers (IHXs) which transfer heat from the primary loop to the secondary or intermediate loop. For a multi-objective optimization problem, a printed circuit heat exchanger-type IHX with zigzag and S-shaped fin channels is selected to be optimized in terms of both the total cost and the heat exchanger thermal effectiveness using genetic algorithms. A computer code is developed to search a set of optimized designs of the zigzag channel geometry. It is found that among the Pareto-optimal solutions, the total cost is approximately linearly related to the thermal effectiveness between 88 and 95% while it rises rapidly after the effectiveness exceeds 95%. An optimal flow channel diameter is also determined through the optimization. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗