Engineering Papers⌕ Search

Engineering topics

Canizares, C. R.

Publications and source records attributed to Canizares, C. R..

At least 19 records

Initial Results From The Chandra High Energy Transmission Grating Spectrometer

The High Energy Transmission Grating Spectrometer (HETGS) on the Chandra X-ray Observatory provides spectral resolving powers of 200-1000 over the range 0.4-8.0 keV (1.5-30 A) with effective area of 2-200 square centimeters. Initial observations during the activation and calibration phases of the mission show that the HETGS is performing as predicted prior to Chandra launch. The talk presented very preliminary results that illustrate the power of the HETGS for performing detailed studies of a wide range of celestial sources, including plasma diagnostics. This written version gives a brief summary of that talk with examples of preliminary spectra of Capella, the Crab pulsar, SS433 and the SNR E0102-72.

Canizares, C. R.↗

Detections of hard X-ray emissions from bright early-type galaxies with ASCA

Five bright elliptical galaxies in the Virgo Cluster, NGC 4365, NGC 4374 (M84), NGC 4406 (M86), NGC 4472 (M49), and NGC 4636, were observed with ASCA. In addition to the extended thermal X-ray emission of temperature kT approximately 1 keV, harder X-rays with color temperature kT greater than or equal to 2 keV were detected from all of them. The 2-10 keV luminosities of this hard component for the five galaxies, integrated within 5 min, are distributed within a relatively narrow range of (1-4) x 10(exp 40) ergs/s. The hard X-ray component is primarily attributed to the integrated emission from discrete X-ray sources. In NGC 4406 and NGC 4374 the data indicate that the hard component is contributed additionally by foreground/background emission from the hot intracluster medium (ICM) of the Virgo Cluster. The hard component of NGC 4472 seems also contributed by the Virgo ICM emission, but in this case there is evidence that the ICM brightness is locally enhanced within approximately 10 min of NGC 4472.

Matsushita, K.↗

The MIT high resolution X-ray spectroscopy instruments on AXAF

The general design and performance characteristics of MIT's two dispersive spectrometers, the Bragg Crystal Spectrometer (BCS) and the High Energy Transmission Grating Spectrometer (HETG), now being developed for the Advanced X-ray Astrophysics Facility (AXAF), are described. Particular attention is given to the development of the critical technologies incorporated into these instruments, including BCS diffractors, imaging gas flow proportional counters, and grating elements for the HETG. The principal stages and the current status of the developments are reviewed.

Canizares, C. R.↗

Proportional counter windows for the Bragg Crystal Spectrometer on AXAF

A Bragg Crystal Spectrometer (BCS) using a gas flow proportional counter as its primary detector is among the instruments under development for AXAF. The BCS will employ windows of 1-micron-thick polyimide coated on both sides with 200 A of Al; this window composition, while X-ray transmitting, will leak gas at a lower rate than the polypropylene film-based windows formerly employed. Accounts are given of the results obtained with additional innovative X-ray window materials currently under development, including diamond and Si-enriched Si3N4.

Markert, T. H.↗

Soft X-ray properties of Seyfert galaxies. I - Spectra

Results are presented from a study of soft X-ray spectra of 75 Seyfert galaxies observed by the Einstein Observatory IPC. The spectra in this sample (mostly high-luminosity Seyfert type 1s) are found to be consistent with a single power-law index alpha = 81. The AGN spectra observed with the IPC are compared with those from higher energy experiments, where AGN spectra have power law indices alpha = 0.7. It is found that the IPC spectra are systematically steeper than the HEAO 1 A-2 spectra of the same Seyfert galaxies, indicating a flattening toward higher energies.

Kruper, J. S.↗

A comparison of three regions of Puppis A

High resolution X-ray spectral observations of Puppis A were performed with the FPCS on the Einstein Observatory at three regions of the remnant: the shock front, the bright eastern knot, and the interior. Plasma diagnostics of lines from OVII and OVIII constrain the values of electron temperature, ionization timescale, and hydrogen column density. Results of the diagnostics for these three regions are compared. A nonequilibrium analysis of previously published fluxes of oxygen lines shows that the interior has not yet reached ionization equilibrium.

Fischbach, K. F.↗

Radio-quiet QSO and the X-ray background

Upper limits on the extragalactic soft X-ray background flux (epsilon of about 0.1-0.3 keV) are used to constrain the contribution of X-ray sources with steep spectra to the X-ray background above 1 keV. The effective spectral index of the extragalactic X-ray background is less than 0.76 over the energy range 0.2 and 3.5 keV. Objects with power-law spectra of energy index 1.4, as recently found for a sample of radio-quiet QSO, cannot contribute more than 13 percent of the 2-10 keV X-ray background.

Fabian, A. C.↗

Do massive black holes reside in elliptical galaxies?

The accretion by a central black hole of the hot interstellar medium in an elliptical galaxy is investigated, and the minimum expected luminosity and manner of its emission is estimated. It is not obviously detected at any wavelength. The problem of 'starving the monster', if indeed there is a monster, is raised. The simplest conclusion from the evidence is that most bright elliptical galaxies do not contain massive black holes.

Fabian, A. C.↗

Transmission grating spectroscopy and the Advanced X-ray Astrophysics Facility (AXAF)

The use of transmission gratings with grazing-incidence telescopes in celestial X-ray astrononmy is reviewed. The basic properties of transmission grating spectrometers and the use of 'phased' gratings to enhance the diffraction efficiency are outlined. The fabrication of the gratings is examined, giving special attention to the AXAF High Energy Transmission Grating. The performance of finite-period thick gratings is briefly discussed, and the performance of the transmission grating spectrometers planned for SPECTROSAT and AXAF are examined.

Schattenburg, M. L.↗

The MIT spectroscopy investigations on AXAF and the study of supernova remnants

The MIT High Resolution X-Ray Spectroscopy experiment on the AXAF, which will study physical conditions in celestial sources by means of detailed measurements of emission and absorption features in their spectra, involves two complementary dispersive instruments: Bragg Crystal Spectrometer (BCS) and High Energy Transmission Grating (HETG). This paper discusses the principles of operation of BCS and HETG and the results that will be obtained by these instruments. Measurements of individual line strengths obtained by the AXAF spectrometers will allow the application of plasma diagnostic techniques to a study of the detailed physical conditions in celestial objects, particularly in the optically thin plasma of supernova remnants, which is particularly well suited to the application of plasma diagnostics.

Canizares, C. R.↗

The X-ray surface brightness distribution and spectral properties of six early-type galaxies

Detailed analysis is presented of the Einstein X-ray observations of six early-type galaxies. The results show that effective cooling is probably present in these systems, at least in the innermost regions. Interaction with the surrounding medium has a major effect on the X-ray surface brightness distribution at large radii, at least for galaxies in clusters. The data do not warrant the general assumptions of isothermality and gravitational hydrostatic equilibrium at large radii. Comparison of the X-ray surface brightness profiles with model predictions indicate that 1/r-squared halos with masses of the order of 10 times the stellar masses are required to match the data. The physical model of White and Chevalier (1984) for steady cooling flows in a King law potential with no heavy halo gives a surface brightness distribution that resembles the data if supernovae heating is present.

Trinchieri, G.↗

High-resolution X-ray spectroscopic evidence of nonequilibrium conditions in the Cygnus Loop

High-resolution spectroscopic X-ray observations of a portion of the Cygnus Loop made with the Focal Plane Crystal Spectrometer aboard the Einstein Observatory are reported. Emission lines for O VII, O VIII, and Ne IX are measured, and upper limits are set to other transitions in O VII and O VIII. The detected emission line fluxes are consistent with emission from an equilibrium plasma with an electron temperature of about 3 x 10 to the 6th K, a value similar to that obtained by numerous previous observers. The absence of any O VII forbidden line emission strongly suggests that the emitting plasma is not in collisional ionization equilibrium. This is shown to be the case using several line diagnostics formed from the observed emission lines and a simple model describing the X-ray emission from an ionizing nonequilibrium plasma.

Vedder, P. W.↗

X-ray studies of galactic and intergalactic gas in the Pegasus I cluster

Einstein Observatory IPC observations of Pegasus I show hot gas in a low density intergalactic medium as well as in a galactic medium within each of the dominant elliptical galaxies, NGC 7619 and NGC 7626. The short central cooling times inferred, of 100 million years or less, suggest that the galaxies contain cooling flows of about 1 solar mass/yr. The intergalactic gas, which is about 5 times less dense than in the least dense of the known Abell clusters, is incapable of stripping the hot gas from the elliptical galaxies or the neutral gas from the spirals. The gas around NGC 7619 appears to be influencing one of the radio lobes of NGC 7626.

Canizares, C. R.↗

An X-ray survey of hot white dwarf stars - Evidence for a m(He)/n(H) versus Teff correlation

Observations of 13 white dwarf and subdwarf stars using the Einstein Observatory High Resolution Image are reported. Included are stars of classes DA, DB, DAV, sDO, and sDB, with optically determined effective temperatures in the range 10,000-60,000 K. X-ray emission was detected from two of the 13: the very hot (55,000 K) DA1 star WD 2309 + 105 (= EG 233), with a count rate one-fifth that of HZ 43, and the relatively cool (26,000 K) DA3 star WD 1052 - 273 (=GD 125). The effective temperatures determined from ultraviolet and optical observations were used to place limits on the He content of the white dwarf photospheres, presuming that trace photospheric He is the missing opacity source which quenches the thermal X-rays in these stars. When presently obtained results were combined with those available from the literature evidence was found for a correlation between Teff and n(He)/n(H), in which HZ 43 is a conspicuous exception to the general trend. Both this correlation and the exceptional behavior of HZ 43 are qualitatively accounted for by a radiative acceleration model, in which the rate of upward movement of the He is a function of temperature and surface gravity

Petre, R.↗

High-resolution X-ray spectroscopy of the Crab Nebula and the oxygen abundance of the interstellar medium

The measurement and analysis of a high-resolution soft X-ray spectrum of the Crab Nebula obtained with the Focal Plane Crystal Spectrometer on the Einstein Observatory are reported. A hydrogen column density of 3.45 + or - 0.42 x 10 to the 21st/sq cm and an oxygen column density of 2.78 + or - 0.55 x 10 to the 18th/sq cm, corresponding to an oxygen abundance of 1.1 + or - 0.3 times solar, were obtained. The absence of any evident oxygen depletion effects suggests that most interstellar grains are reasonably transparent to soft X-rays, implying sizes of less than 0.4 micron. The detailed spectrum in the vicinity of the oxygen edge gives marginal evidence for a resonant absorption line and suggests an edge from singly ionized oxygen.

Schattenburg, M. L.↗

The Bragg crystal spectrometer for AXAF

The goal of MIT's high resolution X-ray spectrometry investigation on the Advanced X-ray Astrophysics Facility is to study the physical conditions in celestial sources by means of detailed measurements of their X-ray spectra. The investigation involves two complimentary dispersive instruments, a Bragg crystal spectrometer (BCS) and a high energy transmission grating spectrometer. Particular attention is given to the BCS which will be used to measure the strengths of individual lines from both point and extended objects in order to apply plasma diagnostic techniques to the study of cosmic X-ray sources.

Canizares, C. R.↗

The high energy transmission grating spectrometer for AXAF

Attention is given to a high energy transmission grating spectrometer that operates over the range 0.4-8 keV, giving resolving powers of 100-1000 and effective areas of 10-200 sq cm. The instrument, which is part of the MIT high resolution X-ray spectroscopy investigation, consists of a single array of grating facets of two types: medium energy gratings of 0.6-micron period, 0.5-micron thick silver mounted behind the outer three AXAF mirrors, and high energy gratings of 0.2-micron period, 1.0-micron thick gold mounted behind the inner three mirrors. The gratings are oriented so as to correct for coma and so that the medium and high energy spectra form a shallow 'X' at the AXAF focal plane. Likely targets include normal stars, binary X-ray sources, active galactic nuclei and quasars. The HETGS can also be used to give moderate resolution spectra of slightly extended sources and monochromatic images of sources with strong lines, such as supernova remnants in nearby galaxies.

Canizares, C. R.↗

X-ray properties of quasars and results from a deep X-ray survey of optically selected objects

A sample of 178 optically selected quasars and Seyfert galaxies is studied. Seventy seven of the objects have measured X-ray fluxes while the remainder have upper limits. The analysis strengthens and confirms the conclusion of Avni and Tananbaum (1982) that the X-ray-to-optical luminosity ratio of optically selected quasars decreases with increasing optical luminosity. The dependence of the ratio on look-back time is small and may be null. This suggests that the effect is intrinsic to the physical processes that give rise to the nonthermal emission in quasars.

Kriss, G. A.↗