Engineering Papers⌕ Search

Engineering topics

Cancelo, G.

Publications and source records attributed to Cancelo, G..

First Search for Dark Photon Dark Matter with a madmax Prototype

We report the first result from a dark photon dark matter search in the mass range from 78.62 to 83.95 μ eV / c 2 with a dielectric haloscope prototype for (Magnetized Disc and Mirror Axion eXperiment). Putative dark photons would convert to detectable photons within a stack consisting of three sapphire disks and a mirror. The emitted power of this system is received by an antenna and successively digitized using a low-noise receiver. No significant signal attributable to dark photons has been observed above the expected background. Assuming unpolarized dark photon dark matter with a local density of ρ χ = 0.3 G eV cm 3 we exclude a dark photon to photon mixing parameter χ > 2.7 × 10 − 12 over the full mass range and χ > 1.1 × 10 − 13 at a mass of 80.57 μ eV / c 2 with a 95% confidence level. This is the first physics result from a prototype and exceeds previous constraints on χ in this mass range by up to almost three orders of magnitude. Published by the American Physical Society 2025

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Confirmation of the spectral excess in DAMIC at SNOLAB with skipper CCDs

Here, we present results from a 3.25 kg–day target exposure of two silicon charge-coupled devices (CCDs), each with 24 megapixels and skipper readout, deployed in the DAMIC setup at SNOLAB. With a reduction in pixel readout noise of a factor of 10 relative to the previous detector, we investigate the excess population of low-energy events in the CCD bulk previously observed above expected backgrounds. We address the dominant systematic uncertainty of the previous analysis through a depth fiducialization designed to reject surface backgrounds on the CCDs. The measured bulk ionization spectrum confirms the presence of an excess population of low-energy events in the CCD target with characteristic rate of ~7 events per kg-day and electron-equivalent energies of ~80 eV, whose origin remains unknown.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Implementing machine learning methods on QICK hardware for qubit readout & control

Quantum readout and control is a fundamental aspect of quantum computing that requires accurate measurement of qubit states. Errors emerge in all stages, from initialization to readout, and identifying errors in post-processing necessitates resource-intensive statistical analysis. In our work, we use a lightweight fully-connected neural network (NN) to classify states of a transmon system with no prior processing. Our NN accelerator yields higher fidelities (92%) than the classical matched filter method (84%). By exploiting the natural parallelism of NNs and their placement near the source of data on field-programmable gate arrays (FPGAs), we can achieve ultra-low latency on the Quantum Instrumentation Control Kit (QICK). Integrating machine learning methods on QICK opens several pathways for efficient real-time processing of quantum circuits.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

EXCESS workshop: Descriptions of rising low-energy spectra

Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was initiated. In its first iteration in June 2021, ten rare event search collaborations contributed to this initiative via talks and discussions. The contributing collaborations were CONNIE, CRESST, DAMIC, EDELWEISS, MINER, NEWS-G, NUCLEUS, RICOCHET, SENSEI and SuperCDMS. They presented data about their observed energy spectra and known backgrounds together with details about the respective measurements. In this paper, we summarize the presented information and give a comprehensive overview of the similarities and differences between the distinct measurements. The provided data is furthermore publicly available on the workshop's data repository together with a plotting tool for visualization.

Adari, Prakruth↗

Measurement of the bulk radioactive contamination of detector-grade silicon with DAMIC at SNOLAB

We present measurements of bulk radiocontaminants in the high-resistivity silicon CCDs from the DAMIC experiment at SNOLAB. We utilize the exquisite spatial resolution of CCDs to discriminate between α and β decays, and to search with high efficiency for the spatially-correlated decays of various radioisotope sequences. Using spatially-correlated β decays, we measure a bulk radioactive contamination of 32 Si in the CCDs of 140 ± 30 μBq/kg, and place an upper limit on bulk 210 Pb of < 160 μBq/kg. Using similar analyses of spatially-correlated α and β decays, we set upper limits of < 11 μBq/kg (0.9 ppt) on 238 U and < 7.3 μBq/kg (1.8 ppt) on 232 Th in the bulk silicon. The ability of DAMIC CCDs to identify and reject spatially-coincident backgrounds, particularly from 32 Si, has significant implications for the next generation of silicon-based dark matter experiments, where β's from 32 Si decay will likely be a dominant background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results on low-mass weakly interacting massive particles from an 11 kg d target exposure of DAMIC at SNOLAB

We present constraints on the existence of weakly interacting massive particles (WIMPs) from a 11 kg-day target exposure of the DAMIC experiment at the SNOLAB underground laboratory. The observed energy spectrum and spatial distribution of ionization events with electron-equivalent energies $>$200 eV$_{\rm ee}$ in the DAMIC CCDs are consistent with backgrounds from natural radioactivity. An excess of ionization events is observed above the analysis threshold of 50 eV$_{\rm ee}$. While the origin of this low-energy excess requires further investigation, our data exclude spin-independent WIMP-nucleon scattering cross sections $\sigma_{\chi-n}$ as low as $3\times 10^{-41}$ cm$^2$ for WIMPs with masses $m_{\chi}$ from 7 to 10 GeV$c^{-2}$ . These results are the strongest constraints from a silicon target on the existence of WIMPs with $m_{\chi}$$<$9 GeV$c^{-2}$ and are directly relevant to any dark matter interpretation of the excess of nuclear-recoil events observed by the CDMS silicon experiment in 2013.

WIMP search, Dark Matter, DAMIC, SNOLAB↗

Differences in the response of two light guide technologies and two readout technologies after an exchange of liquid argon in the dewar

In this investigation the response to the scintillation light generated by through-going cosmic muons in liquid argon (LAr) was measured by two light guide technologies and two readout technologies after five weeks of running in the TallBo dewar at Fermilab. The response was remeasured after the dewar was drained of LAr, refilled, and then run again for an additional four weeks. After the dewar was refilled, there was clear evidence that the scintillation signal had dropped significantly. The two light guide technologies were developed at Indiana University and MIT/Fermilab. The two readout technologies were boards that passively or actively ganged 12 Hamamatsu MPPCs. Two possible explanations were identified for the degraded signal: the response of the two light guide technologies degraded due to damage caused by thermal cycling, and/or unknown differences in the trace residual Xe contamination in the fills of LAr led to the observed drop in scintillation light. Neither absorption nor quenching by N 2 , O 2 , and H 2 O contamination can account for the degradation. Neither the individual Hamamatsu MPPCs nor the passive/active ganging boards appear to have been affected by the thermal cycling. The path length distributions of the cosmics traversing the dewar appear quite similar in both event samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A measurement of absolute efficiency of the ARAPUCA photon detector in liquid argon

In the Fall of 2017, two photon detector designs for the Deep Underground Neutrino Experiment (DUNE) Far Detector were installed and tested in the TallBo liquid argon (LAr) cryostat at the Proton Assembly (PAB) facility, Fermilab. The designs include two light bars developed at Indiana University and a photon detector based on the ARAPUCA light trap engineered by Colorado State University and Fermilab. The performance of these devices is determined by analyzing 8 weeks of cosmic ray data. The current paper focuses solely on the ARAPUCA device as the performance of the light bars will be reported separately. The article briefly describes the ARAPUCA concept, the TallBo setup, and focuses on data analysis and results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Constraints on Light Dark Matter Particles Interacting with Electrons from DAMIC at SNOLAB

We report direct-detection constraints on light dark matter particles interacting with electrons. The results are based on a method that exploits the extremely low levels of leakage current of the DAMIC detector at SNOLAB of 2–6×10-22 A cm^-2. We evaluate the charge distribution of pixels that collect < 10 e- for contributions beyond the leakage current that may be attributed to dark matter interactions. Constraints are placed on so-far unexplored parameter space for dark matter masses between 0.6 and 100 MeV c^-2. We also present new constraints on hidden-photon dark matter with masses in the range 1.2–30 eV c^-2.

Dark Matter, DAMIC, SNOLAB↗

Results from 2015 and the 2016 upgrade of the CONNIE experiment for detecting coherent neutrino nucleus scattering

The CONNIE Experiment (Coherent Neutrino Nucleus Interaction Experiment) is currently collecting reactor neutrino data to search for the undiscovered standard model process of coherent neutrino-nucleus scattering (CNNS). The detector is composed of a silicon target of thick, fully-depleted, low-noise CCD detectors. Results from data collected in 2015 indicate backgrounds are controlled, and allow an estimate of sensitivity to be presented for a larger scale detector. A 2016 upgrade, adding additional target mass, and reducing readout noise, has been performed, increasing the total yield of signal events by a factor of 30, and already yielding science-quality data. Low-energy nuclear calibrations have been performed, enabling calibration down to the device energy threshold. An estimate of the sensitivity expected for measuring the coherent neutrino process is presented. Future prospects with improved detector energy thresholds are estimated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Increasing the efficiency of photon collection in LArTPCs: the ARAPUCA light trap

The Liquid Argon Time Projection Chambers (LArTPCs) are a choice for the next generation of large neutrino detectors due to their optimal performance in particle tracking and calorimetry. The detection of Argon scintillation light plays a crucial role in the event reconstruction as well as the time reference for non-beam physics such as supernovae neutrino detection and baryon number violation studies. Here in this contribution, we present the current R&D work on the ARAPUCA (Argon R&D Advanced Program at UNICAMP), a light trap device to enhance Ar scintillation light collection and thus the overall performance of LArTPCs. The ARAPUCA working principle is based on a suitable combination of dichroic filters and wavelength shifters to achieve a high efficiency in light collection. We discuss the operational principles, the last results of laboratory tests and the application of the ARAPUCA as the alternative photon detection system in the protoDUNE detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Direct-Detection Constraints on eV-Scale Hidden-Photon Dark Matter with DAMIC at SNOLAB

Here, we present direct detection constraints on the absorption of hidden-photon dark matter with particle masses in the range 1.2-30 eV$c^{-2}$ with the DAMIC experiment at SNOLAB. Under the assumption that the local dark matter is entirely constituted of hidden photons, the sensitivity to the kinetic mixing parameter $\kappa$ is competitive with constraints from solar emission, reaching a minimum value of 2.2$\times$$10^{-14}$ at 17 eV$c^{-2}$. These results are the most stringent direct detection constraints on hidden-photon dark matter with masses 3-12 eV$c^{-2}$ and the first demonstration of direct experimental sensitivity to ionization signals $<$12 eV from dark matter interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The CONNIE experiment

Here, the CONNIE experiment uses fully depleted, high resistivity CCDs as particle detectors in an attempt to measure for the first time the Coherent Neutrino-Nucleus Elastic Scattering of antineutrinos from a nuclear reactor with silicon nuclei.This talk, given at the XV Mexican Workshop on Particles and Fields (MWPF), discussed the potential of CONNIE to perform this measurement, the installation progress at the Angra dos Reis nuclear power plant, as well as the plans for future upgrades.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results of the engineering run of the Coherent Neutrino Nucleus Interaction Experiment (CONNIE)

The CONNIE detector prototype is operating at a distance of 30 m from the core of a 3.8 GW(th) nuclear reactor with the goal of establishing Charge-Coupled Devices (CCD) as a new technology for the detection of coherent elastic neutrino-nucleus scattering. We report on the results of the engineering run with an active mass of 4 g of silicon. The CCD array is described, and the performance observed during the first year is discussed. A compact passive shield was deployed around the detector, producing an order of magnitude reduction in the background rate. The remaining background observed during the run was stable, and dominated by internal contamination in the detector packaging materials. The in-situ calibration of the detector using X-ray lines from fluorescence demonstrates good stability of the readout system. The event rates with the reactor ON and OFF are compared, and no excess is observed coming from nuclear fission at the power plant. The upper limit for the neutrino event rate is set two orders of magnitude above the expectations for the standard model. The results demonstrate the cryogenic CCD-based detector can be remotely operated at the reactor site with stable noise below 2 e – RMS and stable background rates. In conclusion, the success of the engineering test provides a clear path for the upgraded 100 g detector to be deployed during 2016.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗