Engineering Papers⌕ Search

Engineering topics

Calaprice, F.

Publications and source records attributed to Calaprice, F..

34 records · Page 2

CALIS—A CALibration Insertion System for the DarkSide-50 dark matter search experiment

This paper describes the design, fabrication, commissioning and use of a CALibration source Insertion System (CALIS) in the DarkSide-50 direct dark matter search experiment. CALIS deploys radioactive sources into the liquid scintillator veto to characterize the detector response and detection efficiency of the DarkSide-50 Liquid Argon Time Projection Chamber, and the surrounding 30 t organic liquid scintillator neutron veto. It was commissioned in September 2014 and has been used successfully in several gamma and neutron source campaigns since then. A description of the hardware and an excerpt of calibration analysis results are given below.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of argon response and light detection in the DarkSide-50 dual phase TPC

A Geant4-based Monte Carlo package named G4DS has been developed to simulate the response of DarkSide-50, an experiment operating since 2013 at LNGS, designed to detect WIMP interactions in liquid argon. In the process of WIMP searches, DarkSide-50 has achieved two fundamental milestones: the rejection of electron recoil background with a power of ~10 7 , using the pulse shape discrimination technique, and the measurement of the residual 39 Ar contamination in underground argon, ~3 orders of magnitude lower with respect to atmospheric argon. These results rely on the accurate simulation of the detector response to the liquid argon scintillation, its ionization, and electron-ion recombination processes. This work provides a complete overview of the DarkSide Monte Carlo and of its performance, with a particular focus on PARIS, the custom-made liquid argon response model.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quenching measurements and modeling of a boron-loaded organic liquid scintillator

Organic liquid scintillators are used in a wide variety of applications in experimental nuclear and particle physics. Boron-loaded scintillators are particularly useful for detecting neutron captures, due to the high thermal neutron capture cross section of 10 B. These scintillators are commonly used in neutron detectors, including the DarkSide-50 neutron veto, where the neutron may produce a signal when it scatters o protons in the scintillator or when it captures on 10 B. Reconstructing the energy of these recoils is complicated by scintillation quenching. Understanding how nuclear recoils are quenched in these scintillators is an important and dicult problem. In this article, we present a set of measurements of neutron-induced proton recoils in a boron-loaded organic liquid scintillator at recoil energies ranging from 57-467 keV, and we compare these measurements to predictions from different quenching models. We and that a modified Birks' model whose denominator is quadratic in dE=dx best describes the measurements, with χ 2 /NDF = 1:6. This result will help model nuclear recoil scintillation in similar detectors and can be used to improve their neutron tagging efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of low electric fields on alpha scintillation light yield in liquid argon

Measurements were made of scintillation light yield of alpha particles from the $^{222}$Rn decay chain within the DarkSide-50 liquid argon time projection chamber. Furthermore, the light yield was found to increase as the applied electric field increased, with alphas in a 200 V/cm electric field exhibiting a 2% increase in light yield compared to alphas in no field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The DarkSide experiment: Present status and future

Here, DarkSide is a multi-stage program devoted to direct searches of Dark Matter particles with detectors based on double phase liquid Argon Time Projection Chamber. The DarkSide-50 setup is running underground at the Laboratori Nazionali del Gran Sasso. First it was operated with Atmospheric Argon and during that run (1422 ± 67) kg×d of truly background-free exposure has been accumulated. Obtained data made it possible to set a 90% C.L. upper limit on the WIMP-nucleon cross section of 6.1 × 10 –44 cm 2 (for a WIMP mass of 100 GeV/c 2 ). Presently the detector is filled with Underground Argon, which is depleted in 39 Ar by a factor of (1.4 ± 0.2)×10 3 with respect to Atmospheric Argon. Acquired so far (2616 ± 43) kg×d (71 live days) in combination with the data from the Atmospheric Argon run give us the 90% C.L. upper limit on the WIMP-nucleon spin-independent cross section of 2.0×10 –44 cm 2 for a WIMP mass of 100 GeV/c 2 . Up to date this is the best limit obtained with an argon target.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The DarkSide-50 Experiment: a Liquid Argon Target for Dark Matter Particles

The DarkSide-50 experiment, located at the “Laboratori Nazionali del Gran Sasso (INFN)”, is based on low-radioactivity argon double phase time projection chamber, surrounded by an active liquid scintillator veto, designed for the zero background achievement. The liquid argon features sufficient self shielding and easy scalability to multi-tons scale. The impressive reduction of the 39 Ar isotope (compared to the atmospheric argon), along with the excellent pulse shape discrimination, make this technology a possible candidate for the forthcoming generation of multi-ton Dark Matter experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

The search for sterile neutrinos with SOX-Borexino

The aim of the SOX-Borexino project is to verify or falsify the existence of eV-scale sterile neutrinos. The existence of sterile neutrinos is suspected because of several anomalies, which were observed in previous experiments. A ~3.7 PBq electron antineutrino source made of {sup 144}Ce will be installed below the Borexino detector at LNGS, Italy, to search for short-baseline oscillations of active-to-sterile neutrinos within the detector volume. Source delivery and beginning of data acquisition is planned for end of 2016, preliminary results are expected already in 2017.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The electronics and data acquisition system for the DarkSide-50 veto detectors

DarkSide-50 is a detector for dark matter candidates in the form of weakly interacting massive particles. It utilizes a liquid argon time projection chamber for the inner main detector, surrounded by a liquid scintillator veto (LSV) and a water Cherenkov veto detector (WCV). The LSV and WCV act as the neutron and cosmogenic muon veto detectors for DarkSide-50. This paper describes the electronics and data acquisition system used for these two detectors. The system is made of a custom built front end electronics and commercial National Instruments high speed digitizers. The front end electronics, the DAQ, and the trigger system have been used to acquire data in the form of zero-suppressed waveform samples from the 110 PMTs of the LSV and the 80 PMTs of the WCV. The veto DAQ system has proven its performance and reliability. This electronics and DAQ system can be scaled and used as it is for the veto of the next generation DarkSide-20k detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Current Status of the dark matter experiment DarkSide-50

DarkSide-50 is a dark matter direct search experiment at LNGS, searching for rare nuclear recoils possibly induced by WIMPs. It has two nested vetoes and a dual phase liquid argon TPC as dark matter detector. Key features of this experiment are the use of underground argon as radio-pure target and of muon and neutron active vetoes to suppress the background. The first data-taking campaign was running from November 2013 to April 2015 with an atmospheric argon target and a reduced efficiency neutron veto due to internal contamination. However, an upper limit on the WIMP-nucleon cross section of 6.1×10 -44 cm 2 at 90% CL was obtained for a WIMP mass of 100 GeV/c 2 and an exposure of (1422 ± 67) kg·d. At present DarkSide-50 started a 3 years run, intended to be background-free because the neutron veto was successfully recovered and underground argon replaced the atmospheric one. Additionally calibration campaigns for both the TPC and the neutron veto were completed. Thanks to the good performance of the background rejection, the results obtained so far suggest the scalability of DarkSide-50 to a ton-scale detector, which will play a key role into the dark matter search scenario.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The DarkSide awakens

Here, the DarkSide program at LNGS aims to perform background-free WIMP searches using two phase liquid argon time projection chambers, with the ultimate goal of covering all parameters down to the so-called neutrino floor. One of the distinct features of the program is the use of underground argon with has a reduced content of the radioactive 39 Ar compared to atmospheric argon. The DarkSide Collaboration is currently operating the DarkSide-50 experiment, the first such WIMP detector using underground argon. Operations with underground argon indicate a suppression of 39 Ar by a factor (1.4 ± 0.2) × 10 3 relative to atmospheric argon. The new results obtained with DarkSide-50 and the plans for the next steps of the DarkSide program, the 20t fiducial mass DarkSide-20k detector and the 200 t fiducial Argo, are reviewed in this proceedings.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A first walk on the DarkSide

DarkSide-50 (DS-50) at Gran Sasso underground laboratory (LNGS), Italy, is a direct dark matter search experiment based on a TPC with liquid argon. DS-50 has completed its first dark matter run using atmospheric argon as target. Here, the DS-50 detector performances and the results of the first physics run are reviewed in this proceeding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results From the First Use of Low Radioactivity Argon in a Dark Matter Search

Liquid argon is a bright scintillator with potent particle identification properties, making it an attractive target for direct-detection dark matter searches. The DarkSide-50 dark matter search here reports the first WIMP search results obtained using a target of low-radioactivity argon. DarkSide-50 is a dark matter detector, using a two-phase liquid argon time projection chamber, located at the Laboratori Nazionali del Gran Sasso. The underground argon is shown to contain Ar39 at a level reduced by a factor (1.4±0.2)×103 relative to atmospheric argon. We report a background-free null result from (2616±43) kg d of data, accumulated over 70.9 live days. When combined with our previous search using an atmospheric argon, the 90% C.L. upper limit on the WIMP-nucleon spin-independent cross section, based on zero events found in the WIMP search regions, is 2.0×10-44 cm2 (8.6×10-44 cm2, 8.0×10-43 cm2) for a WIMP mass of 100 GeV/c2 (1 TeV/c2, 10 TeV/c2).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The veto system of the DarkSide-50 experiment

Nuclear recoil events produced by neutron scatters form one of the most important classes of background in WIMP direct detection experiments, as they may produce nuclear recoils that look exactly like WIMP interactions. In DarkSide-50, we both actively suppress and measure the rate of neutron-induced background events using our neutron veto, composed of a boron-loaded liquid scintillator detector within a water Cherenkov detector. This paper is devoted to the description of the neutron veto system of DarkSide-50, including the detector structure, the fundamentals of event reconstruction and data analysis, and basic performance parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The DarkSide project

DarkSide is a graded experimental project based on radiopure argon, and is now, and will be, used in direct dark matter searches. The present DarkSide-50 detector, operating at the Gran Sasso National Laboratory, is a dual-phase, 50 kg, liquid argon time-projection-chamber surrounded by an active liquid scintillator veto. It is designed to be background free in 3 years of operation. DS-50 performances, when filled with atmospheric argon, are reported. However DS-50 filled with underground argon, shows impressive reduction of the 39Ar isotope. The application of this powerful technology in a future generation of the DarkSide program is discussed.

Agnes, P.↗

The DarkSide Multiton Detector for the Direct Dark Matter Search

A wide range of astronomical evidence implies the existence of Dark Matter, but as yet the nature of this major component of the Universe is completely unknown. A leading candidate explanation is that Dark Matter is composed of Weakly Interacting Massive Particles (WIMPs) formed in the early universe and gravitationally clustered together with the standard baryonic matter. Such WIMPs could in principle be detected through their collisions with ordinary nuclei in a sensitive target, producing observable low-energy (<100 keV) nuclear recoils. The predicted collision rates are very low and require ultra-low background detectors with large (0.1 { 10 tons) target masses, located in deep underground sites to reduce the background produced by neutrons from cosmic ray muons [1{4].

Dark Matter↗