Engineering Papers⌕ Search

Engineering topics

Caggiano, Joseph A

Publications and source records attributed to Caggiano, Joseph A.

Scatter in Cargo Radiography

As a complement to passive detection systems, radiographic inspection of cargo is an increasingly important tool for homeland security because it has the potential to detect highly attenuating objects associated with special nuclear material or surrounding shielding, in addition to screening for items such as drugs or contraband. Radiographic detection of such threat objects relies on high image contrast between regions of different density and atomic number (Z). Threat detection is affected by scatter of the interrogating beamin the cargo, the radiographic system itself, and the surrounding environment, which degrades image contrast. Here, we estimate the extent to which scatter plays a role in radiographic imaging of cargo containers. Stochastic transport simulations were performed to determine the details of the radiography equipment and surrounding environment, which are important in reproducing measured data and to investigate scatter magnitudes for typical cargo. We find that scatter plays a stronger role in cargo radiography than in typicalmedical imaging scenarios, even for low-density cargo, with scatter-toprimary ratios ranging from 0.14 for very low density cargo, to between 0.20 and 0.40 for typical cargo, and higher yet for dense cargo.

99 GENERAL AND MISCELLANEOUS↗

On the Search for Nuclear Resonance Fluorescence Signatures of 235U and 238U above 3 MeV

Nuclear resonance fluorescence is a physical process that provides an isotope-specific signature that could be used for the identification and characterization of materials. The technique involves the detection of prompt discrete-energy photons emitted from a sample that is exposed to MeV-energy photons. Potential applications of the technique range from detection of high explosives to characterization of special nuclear materials such as 235U. Pacific Northwest National Laboratory and Passport Systems have collaborated to conduct a pair of measurements to search for a nuclear resonance fluorescence response of 235U above 3 MeV and of 238U above 5 MeV using an 8 g sample of highly enriched uranium and a 90 g sample of depleted uranium. No new signatures were observed. The minimum detectable integrated cross section for 235U is presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fission fragment isomers populated via {sup 6}Li+{sup 232}Th

Short-lived isomers in fission fragments following bombardment of 45-MeV {sup 6}Li on {sup 232}Th were examined. Isomers in the A{approx}95, 122, and 132 mass regions were observed. New isomeric decays were observed in {sup 121}In[T{sub 1/2}=17(2) mus], {sup 123}In (T{sub 1/2}> or approx.100 mus), and {sup 125}Sb[T{sub 1/2}=25(4) mus]. These isomers are suggested to arise from nu(h{sub 11/2} x d{sub 3/2})7{sup -} and nu(h{sub 11/2} x s{sub 1/2})5{sup -} neutron core excitations coupling with the valence proton.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Potential Applications of Nuclear Resonance Fluorescence

Nuclear resonance fluorescence (NRF) is a photon-based active interrogation approach that provides isotope-specific signatures that can be used to detect and characterize samples. Photon energies are in the range of a few MeV, so that penetration through significant material is possible. Unlike other active interrogation techniques that are based on inducing fission, NRF is sensitive to a wide range of isotopes: for example {sup 11}B, {sup 12}C, {sup 13}C, {sup 14}N, {sup 16}O, {sup 27}Al, {sup 208}Pb, {sup 235}U, {sup 238}U and {sup 239}Pu just to name a few. NRF is most likely to outperform existing technologies for applications requiring isotopic information of sealed samples. Pacific Northwest National Laboratory is conducting a review of potential applications that could be addressed by NRF techniques. These applications cover a wide range of topics, from geo-location, to material assay, to safeguarding the nuclear fuel cycle. The objective of the project is to search for potential applications, define technical requirements, identify physical limitations, conduct an initial assessment of the technique and design a research approach for developing the applications. In this report, our current progress on will be presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Resonance Fluorescence of U-235

Nuclear resonance fluorescence is a physical process that provides an isotopic-specific signature that could be used for the identification and characterization of materials. The technique involves the detection of prompt discrete-energy photons emitted from a sample which is exposed to photons in the MeV energy range. Potential applications of the technique range from detection of high explosives to characterization of special nuclear materials. One isotope of significant interest is 235U. Pacific Northwest National Laboratory and Passport Systems have collaborated to conduct measurements to search for a nuclear resonance fluorescence response of 235U below 3 MeV using a 200 g sample of highly enriched uranium. Nine 235U resonances between 1650 and 2010 keV were identified in the preliminary analysis. Analysis of the measurement data to determine the integrated cross sections of the resonances is in progress.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Using Thin Films to Screen Possible Scintillator Materials

The discovery and optimization of new scintillators has traditionally been a rather slow process due to the difficulties of single crystal growth. This paper discusses the production of polycrystalline scintillator thin films (a few microns thick) which were tested in order to determine what characterizations could be made concerning a material’s ultimate potential as a scintillator prior to pursuing crystal growth. Thin films of CaF2(Eu), CeF3, and CeCl3, all known scintillators, were produced by vapor deposition. The hygroscopic CeCl3 was coated with multiple polymer-aluminum oxide bi-layers. Emission spectra peak wavelengths and decay times agreed with single crystal values. The films were too thin to measure gamma photopeaks, but using alpha energy deposition peaks, one could compare the relative photon yield/MeV between materials. The values obtained appear to give a relevant indication of a material’s light yield potential. The technique also appears useful for quickly determining the proper dopant amount for a given material.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Potential National Security Applications of Nuclear Resonance Fluorescence Methods

The objective of this report is to document the initial investigation into the possible research issues related to the development of NRF-based national security applications. The report discusses several potential applications ranging from measuring uranium enrichment in UF6 canisters to characterization of gas samples. While these applications are varied, there are only a few research issues that need to be addressed to understand the limitation of NRF in solving these problems. These research issues range from source and detector development to measuring small samples. The next effort is to determine how best to answer the research issues, followed by a prioritization of those questions to ensure that the most important are addressed. These issues will be addressed through either analytical calculations, computer simulations, analysis of previous data or collection of new measurements. It will also be beneficial to conduct a thorough examination of a couple of the more promising applications in order to develop concrete examples of how NRF may be applied in specific situations. The goals are to develop an understanding of whether the application of NRF is limited by technology or physics in addressing national security applications, to gain a motivation to explore those possible applications, and to develop a research roadmap so that those possibilities may be made reality.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A High-Efficiency Fieldable Germanium Detector Array

Historically, large germanium arrays for field applications have consisted of multiple detectors each housed in their own cryostat. In order to ruggedize the detectors for field use these cryostats have had additional support material introduced that significantly impacted cryogenic performance. This paper presents the development of a new cryostat design suitable for deployment of ~10 kg of high purity germanium detectors that achieves outstanding cryogenic performance (~5 W at 80 K) while providing the high detection efficiency required for stand-off measurements and the ruggedization required for use in a variety of field applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗