Cader, Tahir

Publications and source records attributed to Cader, Tahir.

Anomalous behavior detection by an artificial intelligence-enabled system with multiple correlated sensors

Multi-metric artificial intelligence (AI)/machine learning (ML) models for detection of anomalous behavior of a machine/system are disclosed. The multi-metric AI/ML models are configured to detect anomalous behavior of systems having multiple sensors that measure correlated sensor metrics such as coolant distribution units (CDUs). The multi-metric AI/ML models perform the anomalous system behavior detection in a manner that enables both a reduction in the amount of sensor instrumentation needed to monitor the system's operational behavior as well as a corresponding reduction in the complexity of the firmware that controls the sensor instrumentation. As such, AI-enabled systems and corresponding methods for anomalous behavior detection disclosed herein offer a technical solution to the technical problem of increased failure rates of existing multi-sensor systems, which is caused by the presence of redundant sensor instrumentation that necessitates complex firmware for controlling the sensor instrumentation.

Serebryakov, Sergey↗

Classification based anomaly detection

An example device includes processing circuitry and a memory. The memory includes instructions that cause the device to perform various functions. The functions include receiving datastreams from a plurality of sensors of a high performance computing system, classifying each datastream of the each sensor to one of a plurality of datastream models, selecting an anomaly detection algorithm from a plurality of anomaly detection algorithms for each datastream, determining parameters of the each anomaly detection algorithm, determining an anomaly threshold for each datastream, and generating an indication that the sensor associated with the datastream is acting anomalously.

Serebryakov, Sergey↗

Prototype Integrated Hydrogen Fuel Cell Powered Data Center (Cooperative Research and Development Final Report)

Data centers are the backbone of the modern economy-from the server rooms that power small- to medium-sized organizations, to the enterprise-class data centers that support American corporations, and the server farms that run cloud computing services. Rather than a traditional grid-centric data center approach, work under the CRADA will be directed towards implementing a proof-of-concept "hydrogen-based" data center utilizing hydrogen fuel cells, electrolyzers, and solar photovoltaics as key building blocks. This integrated proof-of-concept builds on preliminary work done by HPE and its partners Mercedes-Benz Research & Development North America, Inc. (MBRDNA) and Power Innovations, to dramatically simplify the electrical infrastructure in the data center, leverage the latest automotive-scale hydrogen fuel cell technologies, and tightly couple renewably generated DC power directly to the Information Technology (IT). While some limited aspects of this concept have been demonstrated previously the entire integrated proof of concept proposed here has not yet been realized.

08 HYDROGEN↗

Artificial Intelligence for Data Center Operations (AI Ops)

HPC data centers such as the one at NREL's ESIF will increasingly need to rely on automation to keep pace with exascale growth in compute capability and to manage and optimize the data center environment and facility resources. Artificial intelligence (AI) and machine learning (ML) approaches provide the means to improve HPC data center efficiency (energy, operational, and managerial efficiency) and resiliency by learning historical trends and training models to operate on real-time data collected from both IT and facilities sources. The goal of coupled improvement of data center resiliency and energy efficiency through automated data collection and AI has led to a multi-year, multi-staged collaboration between NREL and Hewlett-Packard Enterprise's Advanced Technology Group, referred to as Artificial Intelligence for Data Center Operations (AIOps). The extended efforts within the AIOps project include a common goal of building capabilities for an advanced smart facility and demonstration of data collection and AI modeling techniques in the ESIF data center.

97 MATHEMATICS AND COMPUTING↗

Sustainability, Feasibility, and Economics of a Fuel Cell-Powered Data Center

Data centers, used for cloud computing or data storage, consume huge amounts of power and are increasing rapidly in number, and consequently, this increase in power consumption has raised concerns with green and sustainable energy supplies to minimize carbon emissions. Significant renewable power can be a carbon-free energy source to reduce the carbon footprint of a data center; however, direct integration of wind and solar power with data center causes concern of the power quality for uninterrupted power supply to computer servers. The reliable power supply can be accomplished by using power produced from fuel cells fueled by hydrogen. If fed with hydrogen derived from renewable sources, fuel cells will realize carbon-free data centers. This presentation shows various renewable-integration scenarios to meet reliable and sustainable power requirements for a data center.

25 ENERGY STORAGE↗

Conducting plastic cold plates

Cold plates are described herein. In one example, a cold plate can include a thermally conductive plastic forming a coolant channel that includes a heat spreader formed into the thermally conductive plastic and an exterior surface of the thermally conductive plastic with a coupling location to couple a heat pipe to the exterior surface of the thermally conductive plastic.

97 MATHEMATICS AND COMPUTING↗

Renewable Hydrogen for a Carbon-Free Data Center

Business case analysis of a carbon-free data center using hydrogen-powered fuel cells to meet the data center's power needs. Presented at the U.S. Department of Energy Fuel Cell Technologies Office's Hydrogen and Fuel Cells for Data Center Applications Project Meeting.

30 DIRECT ENERGY CONVERSION↗

Implementing the Data Center Energy Productivity Metric in a High Performance Computing Data Center

As data centers proliferate in size and number, the improvement of their energy efficiency and productivity has become an economic and environmental imperative. Making these improvements requires metrics that are robust, interpretable, and practical. We discuss the properties of a number of the proposed metrics of energy efficiency and productivity. In particular, we focus on the Data Center Energy Productivity (DCeP) metric, which is the ratio of useful work produced by the data center to the energy consumed performing that work. We describe our approach for using DCeP as the principal outcome of a designed experiment using a highly instrumented, high-performance computing data center. We found that DCeP was successful in clearly distinguishing different operational states in the data center, thereby validating its utility as a metric for identifying configurations of hardware and software that would improve energy productivity. We also discuss some of the challenges and benefits associated with implementing the DCeP metric, and we examine the efficacy of the metric in making comparisons within a data center and between data centers.

Sego, Landon H.↗

Implementing the Data Center Energy Productivity Metric

As data centers proliferate in both size and number, their energy efficiency is becoming increasingly important. We discuss the properties of a number of the proposed metrics of energy efficiency and productivity. In particular, we focus on the Data Center Energy Productivity (DCeP) metric, which is the ratio of useful work produced by the data center to the energy consumed performing that work. We describe our approach for using DCeP as the principal outcome of a designed experiment using a highly instrumented, high performance computing data center. We found that DCeP was successful in clearly distinguishing between different operational states in the data center, thereby validating its utility as a metric for identifying configurations of hardware and software that would improve (or even maximize) energy productivity. We also discuss some of the challenges and benefits associated with implementing the DCeP metric, and we examine the efficacy of the metric in making comparisons within a data center and among data centers.

Sego, Landon H↗

Energy Efficient and Sustainable HPC at Pacific Northwest National Laboratory

Power consumption in US data centers has been escalating at an alarming rate. In response to Public Law 109-431, EPA reported that electricity usage by US data centers accounted for 1.5% of the total electricity used in the US in 2006. They projected that if current data center operating practices continue, electricity usage will almost double to 2.9% of the total electricity used in the US in 2011 (EPA, 2007). Consequently EPA issued a call to action to both government and industry to collaborate and set aggressive goals to reduce power consumption in data centers. In the spirit of responding to the findings and recommendations of the EPA report, the Pacific Northwest National Laboratory (PNNL) has teamed with several key organizations including: The Green Grid (TGG), ASHRAE TC9.9, IBM, 3M, and SprayCool. As part of this effort, a highly instrumented liquid-cooled cluster has been installed at PNNL. The cluster is housed in an 800 ft2 data center which resides in a mixed-use data center with a significant amount of instrumentation as well. The eventual objective of the effort is to be able to report the real-time power consumption, energy efficiency, and productivity of the liquid-cooled data center. Preliminary results from the effort at PNNL are reported in this paper. Thermal results are reported for the hottest server components, including the microprocessors and memory DIMMs. Under all conditions tested, the components have not exceeded manufacturers’ specifications. More importantly, the data show that the liquid-cooled servers can be maintained within specifications while rejecting to non-chilled facility water at 78°F (25.6°C). Furthermore, a reasonable extrapolation suggests that the specifications can still be maintained at 86°F (30°C). In an effort to address global warming, work has started on the qualification of a new 3M Fluoroketone fluid that has a Global Warming Potential (GWP) of 1. This GWP is the lowest published value of all commercially available coolants. Details are provided in the body of this paper.

54 ENVIRONMENTAL SCIENCES↗

Real-time Data Center Energy Efficiency At Pacific Northwest National Laboratory

The escalating consumption of power in data centers worldwide has brought the issue of data center energy efficiency to the forefront. Data center owners and operators now regard detailed knowledge of the energy efficiencies of their data centers as a competitive advantage. With funding from the Department of Energy (NNSA), PNNL has undertaken an in-depth analysis of the real-time energy efficiency for its Energy Smart Data Center Test Bed(ESDC-TB), which is housed in the mixed-use EMSL. The analysis is centered around the real-time display of The Green Grid’s proposed DCiE metric. To calculate this metric, PNNL relies on a variety of sources of data. At the ESDC-TB level, the data center is instrumented to the 100% level (all power consumption, and water temperatures and flow rates are measured). Most of this data is monitored in real-time, but the exception to this is with the CRAHs, which rely on a one-time power consumption measurement for the blowers (these are single speed blowers, so a one-time measurement suffices.). Outside of the data center (EMSL facility level), PNNL relies on the following: • Real-time data from the entire chiller plant (five chillers), six chilled water pumps, and one of four cooling towers (blowers only). • One-time power measurements for a single fixed speed pump that is representative of each grouping of pumps (the other pumps are assumed to possess the same power consumption levels). • One-time power measurements for a single two-speed cooling tower blower. This same blower model is deployed in three of the four cooling towers, so is assumed to be representative for all these blowers. • One-time power measurements for a single fixed speed cooling tower pump. This same pump model is deployed in all four cooling towers, so is assumed to be representative for all these pumps. A software tool named FRED was developed by PNNL to acquire, reduce, display, and archive all the data acquired from the ESDC-TB and EMSL. FRED provides the ability to display various levels of real-time data starting at the ESDC-TB and EMSL levels, then to lower levels as desired. For example, for the ESDC-TB, graphical screens are provided at the data center level, the rack level, the server level, and even the component level. In the near-term, FRED will also display the real-time DCiE. One of the major challenges to doing this in a mixed-use facility has been to quantify the power consumption of each major mechanical or electrical subsystem that is attributable to the IT equipment housed within the ESDC-TB (i.e., NW-ICE). PNNL has tackled this issue for its five chiller plant, and the analysis is presented in the paper. The analysis for all the remaining mechanical and electrical subsystems is now underway and will be presented in future publications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Liquid Cooling in Data Centers

Semiconductor manufacturers have aggressively attacked the problem of escalating microprocessor power consumption levels. Today, server manufacturers can purchase microprocessors that currently have power consumption levels capped at 100W maximum. However, total server power levels continue to increase, with the increase in power consumption coming from the supportin chipsets, memory, and other components. In turn, full rack heat loads are very aggressivley climbing as well, and this is making it increasingly difficult and cost-prohibitive for facility owners to cool these high power racks. As a result, facilities owners are turning to alternative, and more energy efficient, cooling solutions that deploy liquids in one form or another. The paper discusses the advent of the adoption of liquid-cooling in high performance computing centers. An overview of the following competing rack-based, liquid-cooling, technologies is provided: in-row, above rack, refrigerated/enclosed rack, rear door heat exchanger, and device-level (i.e., chip-level). Preparation for a liquid-cooled data center, retroft and greenfield (new), is discussed, with a focus on the key issues that are common to all liquid-cooling technologies that depend upon the delivery of water to the rack (or in some deployments, a Coolant Distribution Unit). The paper then discusses, in some detail, the actual implementation and deployment of a liquid device-level cooled (spray cooled) supercomputer at the Pacific Northwest National Laboratory. Initial results from a successful 30 day compliance test show excellent hardware stability, operating system (OS) and software stack stability, application stability and performance, and an availability level that exceeded expectations at 99.94%. The liquid-cooled supercomputer achieved a peak performance of 9.287 TeraFlops, which placed it at number 101 in the June 2007 Top500 fastest supercomputers worldwide. Long-term performance and energy efficiency testing is currently underway, and detailed results will be reported in upcoming publications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗