Engineering PapersSearch

Engineering topics

Cacciani, A.

Publications and source records attributed to Cacciani, A..

Compact Doppler Magnetograph

Here we present a design for a high-performance, compact, low-cost flight instrument that measures velocity and magnetic fields on the photospere. This instrument is called the Compact Doppler Magnetograph, or CDM, and is based on the magneto-optical filter invented by A. Cacciani.

Doppler

A spacecraft going behind the Sun will support SOHO

The problems that can be solved by combining the Solar and Heliospheric Observatory (SOHO) and the magnetic structures on and around the sun (MagSonas) observations are discussed. A magneto-Doppler imager and X and Ka band linearly polarized radio signals sent to the other side of the sun can support extended SOHO mission. This is the purpose of the MagSonas mission. The MagSonas radio system, designed to serve as spacecraft communications and a sounding coronal magnetic field, is described.

Ruzmaikin, A.

L = 1 rotational splitting detected from a 69 day run using the magneto-optical filter installed at JPL

The preliminary analysis of a 69 day observation run taken at the JPL using the magneto-optical filter is presented. The aim is to estimate the rotational splitting of l = 1 modes. A value of Delta nu = 0.44 +/- 0.09 micro-Hz is found. In a second, more accurate analysis, it is planned to investigate the low frequency part of the power spectrum. The observational statistics are presented.

Cacciani, A.

Test of the magneto optical filter during the comet P/Shoemaker-Levy 9 impacts on Jupiter. A Doppler signal detected?

The observations made in July 1994 on the impact of fragment A of the comet P/Shoemaker-Levy 9 with Jupiter are described. The instrumentation used was a magneto-optical filter, acting as a two-channel filter. The data showed a double-peak transient which occurred after the impact, and whose general properties indicated a true jovian origin. The peaks appear in absorption. A numerical simulation can explain the main characteristics of the observed signal where the two peaks have the same polarity and appear only in the channel at shorter wavelengths. The simulation carried out appeared to indicate that the observed signal could be produced by the combination of shock waves and the expanding material with a velocity of 13 +/- 8 km/s. This implies that two separate impacts may have been observed. The developed simulation can be extended to predict long term effects.

Cacciani, A.

Doppler Observations of the Impact of Comet SL9 Fragment A

An attempt to detect Doppler effects on Jupiter during the impact of fragment A of the Shoemaker-Levy 9 comet is discussed. A short description is given of the technique used to observe the impact. Observations are presented, and a theoretical analysis and inter- pretation are given. The instrumentation used is an advanced and more sensitive version of the Magneto-Optical Filter & a 40 cm telescope.

Shoemaker-Levy 9 Jupiter comet fragment A doppler

Observations of intermediate- and high-degree p-mode oscillations during sunspot cycles 21 and 22

Extensive time series of resolved solar images have been available for helioseismological investigations since the late 1970's. The paper presents examples of the frequencies, power levels, modal energies, and widths of solar intermediate-degree and high-degreee p-modes obtained at the Mt. Wilson Observatory's 60-Foot Solar Tower Telescope during the rising phase of the current sunspot cycle. It is shown that the inclusion of frequency splittings from the high-degree p-modes has made it possible to demonstrate that the sun's internal equatorial angular velocity is not constant with radius but varies systematically with radius throughout the solar convection zone and below.

Rhodes, E. J.

Solar magnetic fields measurements with a magneto-optical filter

The presence of a magnetic field at different levels inside the sun has crucial implications for helioseismology. The solar oscillation observing program carried out since 1983 at Mt. Wilson with Cacciani magneto-optical filter has recently been modified to acquire full-disk magnetograms with 2 arcsec spatial resolution. A method for the correct determination of magnetic maps which are free of contamination by velocity signal is presented. It is shown that no cross-talk exists between the Doppler and Zeeman shifts of the Na D lines, provided that instrumental polarization effects are taken into account. The observed line-of-sight photospheric field was used to map the vector field in the inner corona, above active regions, in the current free approximation.

Cacciani, A.

Preparation of a second station for the measurement of solar oscillations of low degree 'l'

An observing station to detect low-degree global solar oscillations is already operational at the Jet Propulsion Laboratory. A second station for continuative measurements of such oscillations has recently been installed and successfully tested in Rome. The high transmission and stability of the magneto-optical filter (MOF) coupled with the lock-in amplifier technique allow analog and real-time detection of oscillation modes with a noise level of only a few cm/s. Observing runs and estimates of the signal-to-noise ratio are shown in time and frequency domains. Routine observations will establish whether the MOF sensitivity and stability are suitable for the detection of stellar oscillations.

Cacciani, A.

The Effects of Seeing on Noise

The effect of the supergranulation velocity field combined with seeing smearing of the solar image on the measurement of solar oscillations is discussed. Depending on the nature of the observational velocity determination scheme, the image motions can shift the background velocity pattern and produce a source of noise that reduces the quality of the observations. The magnitude of this effect is estimated and observational results which are consistent with this estimate are presented.

Ulrich, R. K.

The 1984 solar oscillation program of the Mount Wilson 60-foot tower

The instrumentation, data, and preliminary results from the summer, 1984, solar oscillation observing program which was carried out using the 60-foot tower telescope of the Mt. Wilson Observatory are described. This program was carried out with a dedicated solar oscillation observing system and obtained full-disk Dopplergrams every 40 seconds for up to 11 hours per day. Between June and September, 1984, observations were obtained with a Na magneto-optical filter on 90 different days. The data analysis has progressed to the point that spherical harmonic filter functions were employed to generate a few one-dimensional power spectra from a single day's observations.

Rhodes, E. J., Jr.

The Magneto-optical Filter, Working Principles and Recent Progress

The Magneto-Optical Filter is described which allows simultaneous magnetic and velocity measurements (in both imaging and non-imaging modes) without the need for a spectrograph. In this way the stability and alignment problems of the spectrograph are completely overcome. Its major advantages are: wavelength absolute reference and stability, high signal to noise ratio and independence of the transmission profile from the incidence angle of the solar beam. It is an imaging instrument allowing high wave number analysis in the solar oscillation spectrum and a continuous monitoring of the image position through the chromospheric facular structures. The apparatus in use at Mt. Wilson is assembled in a modular form. The most important part of it is a glass cell containing the sodium vapor. The filter is easy to use but the cell is not easy to construct in an optimal way. The technology is in progress both to use Na and K together and to prevent the windows from becoming coated during a long-term operation.

Cacciani, A.

Evaluation of a Magneto-optical Filter and a Fabry-perot Interferometer for the Measurement of Solar Velocity Fields from Space

A program was developed to evaluate the performance of three different devices as possible space-borne solar velocity field imagers. Two of these three devices, a magneto-optical filter and a molecular adherence Fabry-Perot interferometer were installed in a newly-constructed observing system located at the 60-foot tower telescope at the Mt. Wilson Observatory. Time series of solar filtergrams and Dopplergrams lasting up to 10 hours per day were obtained with the filter while shorter runs were obtained with the Fabry-Perot. Two-dimensional k (sub h)-omega power spectra which show clearly the well-known p-mode ridges were computed from the time series obtained with the magneto-optical filter. These power spectra were compared with similar power spectra obtained recently with the 13.7-m McMath spectrograph at Kitt Peak.

Rhodes, E. J., Jr.

A compact Dopplergraph/magnetograph suitable for space-based measurements of solar oscillations and magnetic fields

A compact Dopplergraph/magnetograph placed in a continuous solar-viewing orbit will allow us to make major advancements in our understanding of solar internal structure and dynamics. An international program is currently being conducted at JPL and Mt. Wilson to develop such an instrument. By combining a unique magneto-optical resonance filter with CID and CCD cameras we have been able to obtain full- and partial-disk Dopplergrams and magnetograms. Time series of the velocity images are converted into k-omega power spectra which show clear- the solar nonradial p-mode oscilations. Magnetograms suitable for studying the long-term evolution of solar active regions have also been obtained with this instrument. A flight instrument based on this concept is being studied for possible inclusion in the SOHO mission.

Rhodes, E. J., Jr.

Applications of the magneto-optical filter to stellar pulsation measurements

A proposed method of employing the Cacciani magneto-optical filter (MOF) for stellar seismology studies is described. The method relies on the fact that the separation of the filter bandpasses in the MOF can be changed by varying the level of input power to the filter cells. With the use of a simple servosystem the bandpass of a MOF can be tuned to compensate for the changes in the radial velocity of a star introduced by the orbital motion of the Earth. Such a tuned filter can then be used to record intensity fluctuations through the MOF bandpass over an extended period of time for each given star. Also, the use of a two cell version of the MOF makes it possible to alternately chop between the bandpass located in the stellar line wing and a second bandpass located in the stellar continuum. Rapid interchange between the two channels makes it possible for atmospheric-introduced noise to be removed from the time series.

Rhodes, E. J., Jr.