Engineering Papers⌕ Search

Engineering topics

Butler, Leslie G.

Publications and source records attributed to Butler, Leslie G..

Theoretical and experimental analysis of the modulated phase grating X-ray interferometer

X-ray grating interferometry allows for the simultaneous acquisition of attenuation, differential-phase contrast, and dark-field images, resulting from X-ray attenuation, refraction, and small-angle scattering, respectively. The modulated phase grating (MPG) interferometer is a recently developed grating interferometry system capable of generating a directly resolvable interference pattern using a relatively large period grating envelope function that is sampled at a pitch that is small enough that X-ray spatial coherence can be achieved by using a microfocus X-ray source or G0 grating. We present the theory of the MPG interferometry system for a 2-dimensional staggered grating, derived using Fourier optics, and we compare the theoretical predictions with experiments we have performed with a microfocus X-ray system at Pennington Biomedical Research Center, LSU. The theoretical and experimental fringe visibility is evaluated as a function of grating-to-detector distance. Additionally, quantitative experiments are performed with porous carbon and alumina compounds, and the mean normalized dark-field signal is compared with independent porosimetry measurements. Qualitative analysis of attenuation and dark-field images of a dried anchovy are shown.

47 OTHER INSTRUMENTATION↗

The Scientific Case for Concurrent Neutron and X-ray Scattering and Spectroscopy

The interrogation of materials with X-rays or neutrons to determine the structure, energetics, and dynamics of materials is fundamental to advancing materials' physical and chemical science and developing innovative material technologies. A transcending challenge in developing novel materials is that progress hinges on understanding the structure and dynamics across multiple time and length scales in complex materials that feature multiple components, interfaces, and compositions. Despite the ever-growing demands on materials’ characterization, existing approaches are almost exclusively based on isolated X-ray or neutron scattering, i.e., an approach commensurate with the more narrowly defined needs of fifty years ago. A three-day workshop sponsored by the U.S. National Science Foundation (NSF) analyzed the demand for concurrent neutron and X-ray (NeX) experiments. It was held at the Spring Hill Suites, San Jose, California, from June 2 to 4, 2022. In this workshop, 70 national and international experts ascertained the crucial need to establish NeX capabilities to advance the science of complex materials and systems in the US. Here, we illustrate the need for NeX scattering and spectroscopy experiments by showcasing examples that span areas as diverse as biomaterials, energy science, soft matter, and nanomaterials. To provide NeX capability will require new instrumentation that enables concurrent experiments. Affected areas include chemistry, soft matter, quantum materials, pure and applied chemistry, bioscience, geoscience, and applied materials. NeX benefits research outcomes due to the complementarity of the two techniques, which is essential for better model refinement. While joint refinement of data from separate neutron and X-ray experiments is critical to avoid ambiguities, especially in multiphase-multicomponent materials, concurrent experiments overcome scientific and technical barriers associated with single measurements, separated by location and, thus, time. Among all the examples, these factors introduce uncertainties in the results that complicate data analysis. [1,2] [3] While models are strongly sample-dependent, the principles of joint refinement are generally applicable to these disciplines, including the development of advanced parameterization, modeling, and analysis techniques that also consider the temporal and spatial resolutions of the two methods, leading to unambiguous data interpretation. Solutions for technical barriers must be found to realize NeX experiments, including developing robust sample environments that meet the optical requirements of neutrons and X-rays.

36 MATERIALS SCIENCE↗

Neutron Imaging of Al6061 Prepared by Solid-State Friction Stir Additive Manufacturing

Solid-state Friction Stir Additive Manufacturing has recently gained attention as a result of its capacity to fabricate large-scale parts while preserving the mechanical properties of the feedstock material. However, the correlation between the quality of layer-by-layer bonding of the deposited metal and processing parameters has remained unknown. Neutron imaging techniques, with 90% total transmission per cm, are employed for Al6061 parts fabricated by MELD ® Technology as a non-destructive evaluation approach for the first time to investigate the layer-by-layer structure of a stadium-shaped ingot in different sections. The post-processed results show the fabricated parts with an optimized set of processing parameters are void-free. However, the hydrocarbon-based feedstock lubricant segregates between the layers, which consequently may lead to non-uniform weaker mechanical properties along the build direction and stimulate crack initiation during mechanical loading. The tensile test results show 14% lower strain-to-failure values in alleged contaminated areas in transmission imaging results. Additionally, layer bonding is significantly impacted by hot-on-hot and hot-on-cold layer deposition schemes, especially for larger layer thicknesses.

36 MATERIALS SCIENCE↗

wavepy - Python package for x-ray grating interferometry with applications in imaging and wavefront characterization

X-ray grating interferometry has been employed for a wide range of imaging applications by using the Talbot self-images of a grating. At synchrotron facilities, it has also been exploited to characterize the coherence and wavefront of the x-ray beam. The method is relatively straightforward, easy to implement, and provides accurate quantitative data. However, to exploit its full potential, it requires highly specialized, robust data analysis. It this work, we have set the framework for the development and dissemination of a robust open-source code that is tailored to the data analysis for imaging and beam characterization using grating interferometry.

Grizolli, Walan↗

Neutron interferometry detection of early crack formation caused by bending fatigue in additively manufactured SS316 dogbones

In our research, fatigue in selective laser melted (SLM) and conventionally manufactured stainless steel (SS) 316 dogbones was studied with neutron imaging methods for attenuation, diffraction, and scattering. Neutron attenuation tomography and Bragg edge imaging did not reveal crack formation. Conversely, to efficiently detect the microcrack evolution, two methods of grating-based neutron interferometry, Talbot-Lau and far-field, were employed. Both interferometry methods detect early crack formation via the dark-field (scattering) images, especially for porous microstructures in the range of 0.6 μm to 2 μm. The dark-field image combines sensitivity to micrometer-sized scattering centers at crack formation with sub-millimeter imaging resolution. The crack formation observed with neutron interferometry dark-field was validated post-imaging with additional fatigue cycles to fracture. Further inspection was performed by scanning electron microscopy (SEM) and optical photography. In the two fatigued dogbones, SLM and conventional crack formation was determined to within 1 mm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Porosity detection in electron beam-melted Ti-6Al-4V using high-resolution neutron imaging and grating-based interferometry

A high-resolution neutron tomography system and a grating-based interferometer are used to explore electron beam-melted titanium test objects. The high-resolution neutron tomography system (attenuation-based imaging) has a pixel size of 6.4 µm, appropriate for detecting voids near 25 µm over a (1.5 cm) 3 volume. The neutron interferometer provides dark-field (small-angle scattering) images with a pixel size of 30 µm. Moreover, the interferometer can be tuned to a scattering length, in this case, 1.97 µm, with a field-of-view of (6 cm)3. The combination of high-resolution imaging with grating-based interferometry provides a way for nondestructive testing of defective titanium samples. A chimney-like pore structure was discovered in the attenuation and dark-field images along one face of an electron beam-melted (EBM) Ti-6Al-4V cube. Tomographic reconstructions of the titanium samples are utilized as a source for a binary volume and for skeletonization of the pores. As a result, the dark-field volume shows features with dimensions near and smaller than the interferometer auto-correlation scattering length.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Study of Morphological Changes in MgH2 Destabilized LiBH4 Systems Using Computed X-ray Microtomography

The objective of this study was to apply three-dimensional x-ray microtomographic imaging to understanding morphologies in the diphasic destabilized hydride system: MgH2 and LiBH4. Each of the single phase hydrides as well as two-phase mixtures at LiBH4:MgH2 ratios of 1:3, 1:1, and 2:1 were prepared by high energy ball milling for 5 minutes (with and without 4 mol % TiCl3 catalyst additions). Samples were imaged using computed microtomography in order to (i) establish measurement conditions leading to maximum absorption contrast between the two phases and (ii) determine interfacial volume. The optimal energy for measurement was determined to be 15 keV (having 18% transmission for the MgH2 phase and above 90% transmission for the LiBH4 phase). This work also focused on the determination of interfacial volume. Results showed that interfacial volume for each of the single phase systems, LiBH4 and MgH2, did not change much with catalysis using 4 mol % TiCl3. However, for the mixed composite system, interphase boundary volume was always higher in the catalyzed system; increasing from 15% to 33% in the 1:3 system, from 11% to 20% in the 1:1 system, and 2% to 14% in the 2:1 system. The parameters studied are expected to govern mass transport (i.e., diffusion) and ultimately lead to microstructure-based improvements on H2 desorption and uptake rates.

36 MATERIALS SCIENCE↗