Engineering Papers⌕ Search

Engineering topics

Burkhardt, Earle

Publications and source records attributed to Burkhardt, Earle.

Final Design and Analysis of the Superconducting Magnets for the Material Plasma Exposure Experiment

The Material Plasma Exposure eXperiment (MPEX), which has completed its final design, is a new linear plasma device to advance the understanding of plasma-material interactions through the generation and delivery of plasmas as they are expected in future fusion reactor divertors. MPEX will be a steady-state device to study high-fluence exposures of plasma-facing materials and components. The requirements for the magnetic field at the heating stages and the target make the application of superconducting coils necessary. The final designs for the superconducting magnets have been developed using three cryostat designs with warm bore diameters of 65 cm and 156 cm. The large bores are required to for other systems such as vacuum, water cooling, and RF power. There are 19 superconducting coils in MPEX that are contained in six cryostats. Although design, fabrication, and testing for the magnets as stand-alone units are straightforward, challenges will arise during the integration of the system. Various field profiles will be used during operation. The magnetic field where the electron cyclotron heating occurs needs to operate at both 1.25 and 2.50 T. Analyses that have been performed on the final design include designing the coils and determining operating currents to meet field requirements, forces between cryostats, the effects of coil and/or cryostat movement, and quench analysis. To ensure that the magnetic field requirements are met, a plan for monitoring the magnetic field at specified locations has been developed which includes the effect of coil and/or cryostat movement.

Burkhardt, Earle↗

TCR Central Shutdown Rod Fine Motion Control

Transformational Challenge Reactor (TCR) is a Helium cooled 3 MWt test reactor that leverages advances in materials and manufacturing, computing, and AI in its design. Classical design of a shutdown rod uses either gravity, pneumatic, or springs to quickly release the Central Shutdown Rod (CSR) containing neutron absorber into the reactor core stopping nuclear reaction. Generally, the motor/actuator resides outside the reactor, but the motion is transmitted through a penetration into the pressure vessel. There are also designs where the control rod drive incorporates magnetic latches with coil residing outside the pressure boundary for precise position control of the rod. We are proposing a magnetic coupling to position the shutdown rod without any penetration into the pressure vessel for the entire drive length of TCR shutdown rod. Electromagnets are currently used in non-power nuclear reactors for shutdown rods, but these electromagnets are resident inside the reactor pressure vessel. This paper will describe the use of an electromagnet outside the pressure vessel to position and release the shutdown rod. A prototype was developed at ORNL to demonstrate the concept, and a design optimization of the ferritic core and material was conducted to maximize the lift force of the electromagnet. An elevated temperature testing was also performed to ensure that the system will perform under the temperature conditions inside an operating reactor.

Fountain, Eliott J.↗