Engineering Papers⌕ Search

Engineering topics

Burke, Thomas

Publications and source records attributed to Burke, Thomas.

Water heating energy use reductions from EPA WaterSense lavatory plumbing fittings

Hot water savings from water-efficient lavatory fittings lead to reductions in water heating energy consumption, and ultimately to decreases in carbon emissions. This paper characterizes existing and proposed approaches used to estimate hot water savings and carbon emissions reductions stemming from the U.S. Environmental Protection Agency's WaterSense program. Also described are refinements that improve the accuracy of residential hot water use percentage estimates of lavatory fittings. The authors conclude that (1) hot water percentages for showers and faucets calculated using up-to-date, publicly available national data are consistent with those found by regional studies and household-level models of water use; (2) the accuracy of heating energy savings estimates attributable to WaterSense-labeled lavatory products, as well as associated emissions reductions, can be refined by modifying the existing energy factor/uniform energy factor (EF/UEF)-based estimation approach with available data. The refined approach accounts for more nuanced conditions than the EF/UED-based approach but depends on data not always available; and (3) the approaches described and intermediate outputs can be generalized for other water conservation programs or estimating purposes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Adapter Python IO (Adapter) v1.0

The Adapter Python IO software, in short Adapter or the Adapter software, encapsulates certain Python IO capabilities used for loading in and writing out data when performing analytical Python code runs. More specificcally, it provides a Python API to load data tables from various formats such as XLSX (MS Excel), CSV, and database, into Python code as Pandas DataFrames, as well as to write out tables into a database or CSV files. The Adapter software standardizes a way to point the code to one or multiple input files of one or multiple formats. Therefore, its main feature is the ability to convert data tables identified in one main and, optionally, one or more additional input files, into database tables and Pandas DataFrames for downstream usage in any compatible software. In addition to the loading capability, an instance of the Adapter IO object has the capability to write data out. If the write capability is invoked, all loaded tables are written as either a single database or a set of CSV files, or both, to a location specified in the dedicated input table.

Grahovac, Milica↗

Using Field-Metered Data to Quantify Annual Energy Use of Portable Air Conditioners

As many regions of the United States experience rising temperatures, consumers have come to rely increasingly on cooling appliances (including portable air conditioners) to provide a comfortable indoor temperature. Home occupants sometimes use a portable air conditioner (PAC) to maintain a desired indoor temperature in a single room or enclosed space. Although PACs in residential use are few compared to centrally installed and room air conditioning (AC) units, the past few years have witnessed an increase of PACs use throughout the United States. There is, however, little information and few research projects focused on the energy consumption and performance of PACs, particularly studies that collect information from field applications of PACs. The operation and energy consumption of PACs may differ among geographic locations and households, because of variations in cooling load, frequency, duration of use, and other user-selected settings. In addition, the performance of building envelope (thermal mass and air leakage) as well as inter-zonal mixing within the building would substantially influence the ability to control and maintain desirable indoor thermal conditions. Lawrence Berkeley National Laboratory (LBNL) conducted an initial field-metering study aimed at increasing the knowledge and data related to PAC operation and energy consumption in the United States. LBNL performed its field-metering study from mid-April to late October 2014. The study, which monitored 19 sites in the Northeastern United States (4 in upstate New York and 15 near Philadelphia), collected real-time data on PAC energy consumption along with information regarding housing characteristics, consumer behavior, and environmental conditions that were expected to affect PAC performance. Given the limited number of test sites, this study was not intended to be statistically representative of PAC users in the United States but rather to understand the system response to the cooling demand and to some extent, the operating hours of the studied units. Specifically, the primary objectives of the field-metering study were to (1) expand knowledge of the installation, energy consumption profiles, consumer patterns of use, and environmental parameters related to PAC use; (2) develop distributions of hours of PAC operation for three operating modes: standby, 1 fan-only, and cooling; and (3) describe how individual consumers’ selection of PAC capacity, the area of the space to be cooled, the temperature set point, and environmental conditions affect energy use. Beginning to understand the energy consumption of PACs operating in American homes and commercial settings will help develop a more accurate energy use profile that characterizes relevant variables. This report on LBNL’s field-metering study of PAC energy use describes: a general definition of a PAC and how it operates (section 2); current practices and sources of data for estimating PAC energy use (section 3); the process LBNL used to select field-metering sites, along with characteristics of the sites and the PACs studied (section 4); data collection methods and instrumentation (section 5); analysis methods (section 6); results and discussion (section 7); and conclusions (section 8).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Using Field-Metered Data to Quantify Annual Energy Use of Portable Air Conditioners

As many regions of the United States experience rising temperatures, consumers have come to rely increasingly on cooling appliances (including portable air conditioners) to provide a comfortable indoor temperature. Home occupants sometimes use a portable air conditioner (PAC) to maintain a desired indoor temperature in a single room or enclosed space. Although PACs in residential use are few compared to centrally installed and room air conditioning (AC) units, the past few years have witnessed an increase of PACs use throughout the United States. There is, however, little information and few research projects focused on the energy consumption and performance of PACs, particularly studies that collect information from field applications of PACs. The operation and energy consumption of PACs may differ among geographic locations and households, because of variations in cooling load, frequency, duration of use, and other user-selected settings. In addition, the performance of building envelope (thermal mass and air leakage) as well as inter-zonal mixing within the building would substantially influence the ability to control and maintain desirable indoor thermal conditions. Lawrence Berkeley National Laboratory (LBNL) conducted an initial field-metering study aimed at increasing the knowledge and data related to PAC operation and energy consumption in the United States.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measured Radiation Patterns of the Boeing 91-Element ICAPA Antenna With Comparison to Calculations

This report presents measured antenna patterns of the Boeing 91-Element Integrated Circuit Active Phased Array (ICAPA) Antenna at 19.85 GHz. These patterns were taken in support of various communication experiments that were performed using the antenna as a testbed. The goal here is to establish a foundation of the performance of the antenna for the experiments. An independent variable used in the communication experiments was the scan angle of the antenna. Therefore, the results presented here are patterns as a function of scan angle, at the stated frequency. Only a limited number of scan angles could be measured. Therefore, a computer program was written to simulate the pattern performance of the antenna at any scan angle. This program can be used to facilitate further study of the antenna. The computed patterns from this program are compared to the measured patterns as a means of validating the model.

Lambert, Kevin M.↗

Use of a Scale Model in the Design of Modifications to the NASA Glenn Icing Research Tunnel

Major modifications were made in 1999 to the 6- by 9-Foot (1.8- by 2.7-m) Icing Research tunnel (IRT) at the NASA Glenn Research Center, including replacement of its heat exchanger and associated ducts and turning vanes, and the addition of fan outlet guide vanes (OGV's). A one-tenth scale model of the IRT (designated as the SMIRT) was constructed with and without these modifications and tested to increase confidence in obtaining expected improvements in flow quality around the tunnel loop. The SMIRT is itself an aerodynamic test facility whose flow patterns without modifications have been shown to be accurate, scaled representations of those measured in the IRT prior to the 1999 upgrade program. In addition, tests in the SMIRT equipped with simulated OGV's indicated that these devices in the IRT might reduce flow distortions immediately downstream of the fan by two thirds. Flow quality parameters measured in the SMIRT were projected to the full-size modified IRT, and quantitative estimates of improvements in flow quality were given prior to construction. In this paper, the results of extensive flow quality studies conducted in the SMIRT are documented. Samples of these are then compared with equivalent measurements made in the full-scale IRT, both before and after its configuration was upgraded. Airspeed, turbulence intensity, and flow angularity distributions are presented for cross sections downstream of the drive fan, both upstream and downstream of the replacement flat heat exchanger, in the stilling chamber, in the test section, and in the wakes of the new comer turning vanes with their unique expanding and contracting designs. Lessons learned from these scale-model studies are discussed.

Canacci, Victor A.↗