Engineering Papers⌕ Search

Engineering topics

Burenkov, A.

Publications and source records attributed to Burenkov, A..

VUV-sensitive Silicon Photomultipliers for Xenon Scintillation Light Detection in nEXO

Future ton-scale liquefied noble gas detectors depend on efficient light detection in the vacuum ultraviolet (VUV) range. In the past years, silicon photomultipliers (SiPMs) have emerged as a valid alternative to standard photomultiplier tubes or large-area avalanche photodiodes. The next-generation double-beta decay experiment, nEXO, with a 5-ton liquid xenon time projection chamber will use SiPMs for detecting the 175-nm xenon scintillation light, in order to achieve an energy resolution of σ/Q ββ =1 %. This paper presents recent measurements of the VUV-HD generation SiPMs from Fondazione Bruno Kessler, Trento, Italy, in two complementary setups. It includes measurements of the photon-detection efficiency (PDE) with gaseous xenon scintillation light in a vacuum setup and dark measurements in a dry nitrogen gas setup. Here, we report improved PDE at 175 nm compared to previous generation devices that would meet the criteria of nEXO. Furthermore, we present the projected nEXO detector light collection and energy resolution that could be achieved by using these SiPMs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of silicon photomultiplier performance in external electric fields

In this paper, we report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149 K, relative to their performance in the absence of an external electric field. The SiPM devices used in this study show stable gain, photon detection efficiency, and rates of correlated pulses, when exposed to external fields, within the estimated uncertainties. No visible damage to the surface of the devices was caused by the exposure.

Noble liquid detectors (scintillation, ionization,↗

Characterization of an Ionization Readout Tile for nEXO

Anewdesign for the anode of a time projection chamber, consisting of a charge-detecting "tile", is investigated for use in large scale liquid xenon detectors. The tile is produced by depositing 60 orthogonal metal charge-collecting strips, 3 mm wide, on a 10 cm 10 cm fused-silica wafer. These charge tiles may be employed by large detectors, such as the proposed tonne-scale nEXO experiment to search for neutrinoless double-beta decay. Modular by design, an array of tiles can cover a sizable area. The width of each strip is small compared to the size of the tile, so a Frisch grid is not required. A grid-less, tiled anode design is beneficial for an experiment such as nEXO, where a wire tensioning support structure and Frisch grid might contribute radioactive backgrounds and would have to be designed to accommodate cycling to cryogenic temperatures. The segmented anode also reduces some degeneracies in signal reconstruction that arise in large-area crossed-wire time projection chambers. A prototype tile was tested in a cell containing liquid xenon. Very good agreement is achieved between the measured ionization spectrum of a 207Bi source and simulations that include the microphysics of recombination in xenon and a detailed modeling of the electrostatic field of the detector. An energy resolution E=5.5% is observed at 570 keV, comparable to the best intrinsic ionization-only resolution reported in literature for liquid xenon at 936 V/cm.

Jewell, M J.↗

Measurement of the drift velocity and transverse diffusion of electrons in liquid xenon with the EXO-200 detector

The EXO-200 Collaboration is searching for neutrinoless double β decay using a liquid xenon (LXe) time projection chamber. This measurement relies on modeling the transport of charge deposits produced by interactions in the LXe to allow discrimination between signal and background events. In this paper, we present measurements of the transverse diffusion constant and drift velocity of electrons at drift fields between 20 V/cm and 615 V/cm using EXO-200 data. Finally, at the operating field of 380 V/cm EXO-200 measures a drift velocity of 1.705 +0.014 –0.010 mm/μs and a transverse diffusion coefficient of 55 ± 4 cm 2 /s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

COHERENT Experiment: current status

The COHERENT Collaboration is realizing a long term neutrino physics research program. The main goals of the program are to detect and study elastic neutrino-nucleus scattering (CEνNS). This process is predicted by Standard Model but it has never been observed experimentally because of the very low energy of the recoil nucleus. COHERENT is using different detector technologies: CsI[Na] and NaI scintillator crystals, a single-phase liquid Ar and a Ge detectors. The placement of all the detector setups is in the basement of the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The current status of the COHERENT experimental program is presented.

36 MATERIALS SCIENCE↗

Cosmogenic backgrounds to $0νββ$ in EXO-200

As neutrinoless double-beta decay experiments become more sensitive and intrinsic radioactivity in detector materials is reduced, previously minor contributions to the background must be understood and eliminated. With this in mind, cosmogenic backgrounds have been studied with the EXO-200 experiment. Using the EXO-200 TPC, the muon flux (through a flat horizontal surface) underground at the Waste Isolation Pilot Plant (WIPP) has been measured to be $Φ$ = 4.07±0.14 (sys)±0.03 (stat)×10 -7 cm -2 s -1 , with a vertical intensity of $I_v$ = 2.97+0.14-0.13 (sys) ± 0.02 (stat) × 10 -7 cm -2 s -1 sr -1 . Simulations of muon-induced backgrounds identified several potential cosmogenic radionuclides, though only 137 Xe is a significant background for the 136 Xe $0νββ$ search with EXO-200. Muon-induced neutron backgrounds were measured using $γ$-rays from neutron capture on the detector materials. This provided a measurement of 137 Xe yield, and a test of the accuracy of the neutron production and transport simulations. The independently measured rates of 136 Xe neutron capture and of 137 Xe decay agree within uncertainties. Geant4 and FLUKA simulations were performed to estimate neutron capture rates, and these estimates agreed to within ~ 40% or better with measurements. The ability to identify 136 Xe($n,γ$) events will allow for rejection of 137 Xe backgrounds in future $0νββ$ analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

Search for 2 ν β β decay of Xe 136 to the 0 1 + excited state of Ba 136 with the EXO-200 liquid xenon detector

EXO-200 is a single phase liquid xenon detector designed to search for neutrinoless ββ decay of 136 Xe to the ground state of 136 Ba. We report here on a search for the two-neutrino ββ decay of 136 Xe to the first 0 + excited state, 0 + 1 , of Ba136 based on a 100 kg yr exposure of 136 Xe. Using a specialized analysis employing a machine learning algorithm, we obtain a 90% CL half-life sensitivity of 1.7×10 24 yr. We find no statistically significant evidence for the 2νββ decay to the excited state resulting in a lower limit of T 2ν 1/2 (0 + → 0 + 1 ) > 6.9 ×10 23 yr at 90% CL. In conclusion, this observed limit is consistent with the estimated half-life of 2.5×10 25 yr.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗