Engineering Papers⌕ Search

Engineering topics

Burcher, E. E.

Publications and source records attributed to Burcher, E. E..

29 records · Page 2

Optical analysis of a compound quasi-microscope for planetary landers

A quasi-microscope concept, consisting of facsimile camera augmented with an auxiliary lens as a magnifier, was introduced and analyzed. The performance achievable with this concept was primarily limited by a trade-off between resolution and object field; this approach leads to a limiting resolution of 20 microns when used with the Viking lander camera (which has an angular resolution of 0.04 deg). An optical system is analyzed which includes a field lens between camera and auxiliary lens to overcome this limitation. It is found that this system, referred to as a compound quasi-microscope, can provide improved resolution (to about 2 microns ) and a larger object field. However, this improvement is at the expense of increased complexity, special camera design requirements, and tighter tolerances on the distances between optical components.

Wall, S. D.↗

Transmitting and reflecting diffuser

A near-Lambertian diffuser is described which transmits and reflects ultraviolet light. An ultraviolet grade fused silica substrate is coated with vaporized fuse silica. The coating thickness is controlled, one thickness causing ultraviolet light to diffuse and another thickness causing ultraviolet light to reflect a near Lambertian pattern.

Keafer, L. S., Jr.↗

Design and evaluation of controls for drift, video gain, and color balance in spaceborne facsimile cameras

The facsimile camera is an optical-mechanical scanning device which has become an attractive candidate as an imaging system for planetary landers and rovers. This paper presents electronic techniques which permit the acquisition and reconstruction of high quality images with this device, even under varying lighting conditions. These techniques include a control for low frequency noise and drift, an automatic gain control, a pulse-duration light modulation scheme, and a relative spectral gain control. Taken together, these techniques allow the reconstruction of radiometrically accurate and properly balanced color images from facsimile camera video data. These techniques have been incorporated into a facsimile camera and reproduction system, and experimental results are presented for each technique and for the complete system.

Katzberg, S. J.↗

Electro-optical device for monitoring wire size

Device recognizes variations in wire size and is being used during computer memory-plane fabrication. Decrease in wire diameter, due to stretching, permits removal of wire from memory-plant mold. Monitoring provides means of detecting imperfect wire and permits fabrication of computer memory plane to be stopped prior to its insertion into mold.

Burcher, E. E.↗

Automatic focus control for facsimile camera

Focus control performs function of automatically focusing facsimile camera throughout object field being scanned. It does this by determining and adjusting focus of imaging sensor accordingly. Since facsimile camera images a scene by scanning discrete strips, it is possible to have entire three-dimensional scene in perfect focus at point of imaging by use of focus control.

Sinclair, A. R.↗

First-order optical analysis of a quasi-microscope for planetary landers

A first-order geometrical optics analysis of a facsimile camera augmented with an auxiliary lens as magnifier is presented. This concept, called quasi-microscope, bridges the gap between surface resolutions of the order of 1 to 10 mm which can be obtained directly with planetary lander cameras and resolutions of the order of 0.2 to 10 microns which can be obtained only with relatively complex microscopes. A facsimile camera was considered in the analysis; however, the analytical results can also be applied to television and film cameras. It was found that quasi-microscope resolutions in the range from 10 to 100 microns are obtainable with current state-of-the-art lander facsimile cameras. For the Viking lander camera having an angular resolution of 0.04 deg, which was considered as a specific example, the best achievable resolution would be about 20 microns. The preferred approach to increase the resolution of the quasi-microscope would be, if possible, through an increase in angular resolution of the camera. A twofold to threefold improvement in resolution could also be achieved with a special camera focus position, but this approach tends to require larger and heavier auxiliary optics.

Huck, F. O.↗

Laser communication system for controlling several functions at a location remote to the laser

A multichannel laser remote control system is described. The system is used in areas where radio frequency, acoustic, and hardware control systems are unsatisfactory or prohibited and where line of sight is unobstructed. A modulated continuous wave helium-neon laser is used as the transmitter and a 360 degree light collector serves as the antenna at the receiver.

Burcher, E. E.↗

A transmitting and reflecting diffuser for ultraviolet light

Fabrication of ultraviolet radiation diffusing layer in configuration that uses ultraviolet properties of fused silica condensate is discussed. Construction and operation of the device are described. Diagram of reflecting diffuser to show construction and method of operation is included.

Keafer, L. S., Jr.↗

Multispectral facsimile reproducer

Facsimile reproducer records spatially well-registered true-color and false-color video data on tape. Proposed optical arrangement allows light sources to be adjusted along the mirror scanning direction in such a manner that no electronic delays are required if the reproducer is operated synchronously with the camera.

Burcher, E. E.↗