Engineering topics
Bumble, B.
Publications and source records attributed to Bumble, B..
Development of a Massive, Highly Multiplexible, Phonon-Mediated Particle Detector Using Kinetic Inductance Detectors
Here, we present a status update on the development of a phonon-mediated particle detector using kinetic inductance detector (KID). The design is intended for \(\mathscr {O}(1)\) kg substrate, using \(\mathscr {O}(10^{2})\) KIDs on a single readout line, to image the athermal phonon distribution at < 1 mm position resolution and \(\mathscr {O}(10)\) eV energy resolution. The design specification is set by the need to improve position reconstruction fidelity while maintaining low energy threshold for future rare-event searches such as for low-mass dark matter. Furthermore, we report on the design, which shows negligible crosstalk and > 95% inductor current uniformity, using the coplanar waveguide feedline, ground shield, and a new class of KIDs with symmetric coplanar stripline (sCPS) inductor. The multiplexing is designed upon the frequency-geometry relation we develop for the sCPS KIDs. We introduce the fabrications of the Nb RF assessment prototypes and the high phonon collection efficiency Al–Nb devices. We achieve \(\lesssim \) 0.07% frequency displacement on a 80-KID RF assessment prototype, and the result indicates that we may place more than 180 resonances in our 0.4 GHz readout band with minimal frequency misordering. The coupling quality factors are \(\sim \) 10 \(^{5}\) as designed. Finally, we update our work in progress in fabricating the \(\mathscr {O}(10^{2})\) KID, bi-material, \(\mathscr {O}(1)\) kg detectors, and the expected position and energy resolutions.
Search for optical pulsations in PSR J0337+1715
In this study, we report on a search for optical pulsations from PSR J0337+1715 at its observed radio pulse period. PSR J0337+1715 is a millisecond pulsar (2.7 ms spin period) in a triple hierarchical system with two white dwarfs, and has a known optical counterpart with g-band magnitude 18. The observations were done with the Array Camera for Optical to Near-IR Spectrophotometry (ARCONS) at the 200" Hale telescope at Palomar Observatory. No significant pulsations were found in the range 4000-11000 angstroms, and we can limit pulsed emission in g-band to be fainter than 25 mag.
A frequency and sensitivity tunable microresonator array for high-speed quantum processor readout
Superconducting microresonators have been successfully utilized as detection elements for a wide variety of applications. With multiplexing factors exceeding 1000 detectors per transmission line, they are the most scalable low-temperature detector technology demonstrated to date. For high-throughput applications, fewer detectors can be coupled to a single wire but utilize a larger per-detector bandwidth. For all existing designs, fluctuations in fabrication tolerances result in a non-uniform shift in resonance frequency and sensitivity, which ultimately limits the efficiency of bandwidth utilization. Here, we present the design, implementation, and initial characterization of a superconducting microresonator readout integrating two tunable inductances per detector. We demonstrate that these tuning elements provide independent control of both the detector frequency and sensitivity, allowing us to maximize the transmission line bandwidth utilization. Finally, we discuss the integration of these detectors in a multilayer fabrication stack for high-speed readout of the D-Wave quantum processor, highlighting the use of control and routing circuitry composed of single-flux-quantum loops to minimize the number of control wires at the lowest temperature stage.
Arrays of membrane isolated yttrium-barium-copper-oxide kinetic inductance bolometers
We are developing of arrays of membrane isolated resonator-bolometers, each with a kinetic inductance device (KID) to measure the temperature of the membrane. The KIDs are fabricated out of the high temperature superconductor YBCO to allow operation at relatively high temperatures. The bolometers are designed to offer higher sensitivity than sensors operating at 300 K, but they require less expensive and lighter weight cooling than even more sensitive conventional superconducting detectors operating at lower temperatures. The bolometer arrays are applicable as focal planes in infrared imaging spectrometers, such as for planetary science missions or earth observing satellites. We describe the devices and present measurements of their sensitivity.
Direct Detection of SDSS J0926+3624 Orbital Expansion with ARCONS
AM Canum Venaticorum (AM CVn) stars belong to a class of ultra-compact, short period binaries with spectra dominated largely by helium. SDSS J0926+3624 is of particular interest as it is the first observed eclipsing AM CVn system. We observed SDSS J0926+3624 with the \textbf{Ar}ray \textbf{C}amera for \textbf{O}ptical to \textbf{N}ear-IR \textbf{S}pectrophotometry (ARCONS) at the Palomar 200" telescope. ARCONS uses a relatively new type of energy-resolved photon counters called Microwave Kinetic Inductance Detectors (MKIDs). ARCONS, sensitive to radiation from 350 to 1100 nm, has a time resolution of several microseconds and can measure the energy of a photon to $\sim10%$. We present the light curves for these observations and examine changes in orbital period from prior observations. Using a quadratic ephemeris model, we measure a period rate of change $\dot{P} = (3.07 \pm 0.56)\times 10^{-13}$. In addition, we use the high timing resolution of ARCONS to examine the system's high frequency variations and search for possible quasi-periodic oscillations (QPOs). Finally, we use the instrument's spectral resolution to examine the light curves in various wavelength bands. We do not find any high frequency QPOs or significant spectral variability throughout an eclipse.
EXCESS OPTICAL ENHANCEMENT OBSERVED WITH ARCONS FOR EARLY CRAB GIANT PULSES
We observe an extraordinary link in the Crab pulsar between the enhancement of an optical pulse and the timing of the corresponding giant radio pulse. At optical through infrared wavelengths, our observations use the high time resolution of ARray Camera for Optical to Near-IR Spectrophotometry, a unique superconducting energy-resolving photon-counting array at the Palomar 200 inch telescope. At radio wavelengths, we observe with the Robert C. Byrd Green Bank Telescope and the Green Bank Ultimate Pulsar Processing Instrument backend. We see an 11.3% ± 2.5% increase in peak optical flux for pulses that have an accompanying giant radio pulse arriving near the peak of the optical main pulse, in contrast to a 3.2% ± 0.5% increase when an accompanying giant radio pulse arrives soon after the optical peak. We also observe that the peak of the optical main pulse is 2.8% ± 0.8% enhanced when there is a giant radio pulse accompanying the optical interpulse. We observe no statistically significant spectral differences between optical pulses accompanied by and not accompanied by giant radio pulses. Our results extend previous observations of optical-radio correlation to the time and spectral domains. Our refined temporal correlation suggests that optical and radio emission are indeed causally linked, and the lack of spectral differences suggests that the same mechanism is responsible for all optical emission.
Demonstration and Design Criteria of Transition-Edge Sensors (TESs) with Noise Equivalent Power Below 10 (exp -19) W/Hz(sup 1/2) for Space-Borne Grating Spectrometers
No abstract available
Comparing Transition-Edge Sensor Response Times in a Modified Contact Scheme with Different Support Beams
We present measurements of the thermal conductance, G, and effective time constants, tau, of three transition-edge sensors (TESs) populated in arrays operated from 80-87mK with T(sub C) approximately 120mK. Our TES arrays include several variations of thermal architecture enabling determination of the architecture that demonstrates the minimum noise equivalent power (NEP), the lowest tau and the trade-offs among designs. The three TESs we report here have identical Mo/Cu bilayer thermistors and wiring structures, while the thermal architectures are: 1) a TES with straight support beams of 1mm length, 2) a TES with meander support beams of total length 2mm and with 2 phononfilter blocks per beam, and 3) a TES with meander support beams of total length 2mm and with 6 phonon-filter blocks per beam. Our wiring scheme aims to lower the thermistor normal state resistance R(sub N) and increase the sharpness of the transition alpha=dlogR/dlogT at the transition temperature T(sub C). We find an upper limit of given by (25+/-10), and G values of 200fW/K for 1), 15fW/K for 2), and 10fW/K for 3). The value of alpha can be improved by slightly increasing the length of our thermistors.
Development of Fast, Background-Limited Transition-Edge Sensors for the Background-Limited Infrared/Sub-Millimetre Spectrograph (BLISS) for SPICA
We report experimental progress toward demonstrating background-limited arrays of membrane-isolated transition-edge sensors (TESs) for the Background Limited Infrared/Sub-mm Spectrograph (BLISS). BLISS is a space-borne instrument with grating spectrometers for wavelengths lambda = 35-435 microns and with R = lambda/(delta)lambda approx. 500. The goals for BLISS TESs are: noise equivalent power (NEP) = 5x10(exp -20) W/Hz(1/2) and response time t<30ms. We expect background-limited performance from bilayers TESs with T(sub c)=65mK and G=15fW/K. However, such TESs cannot be operated at 50mK unless stray power on the devices, or dark power PD, is less than 200aW. We describe criteria for measuring P? that requires accurate knowledge of TC. Ultimately, we fabricated superconducting thermistors from Ir (T(sub c) > or = 135mK) and Mo/Cu proximitized bilayers, where T(sub c) is the thermistor transition temperature. We measured the Ir TES arrays in our 50mK adiabatic demagnetization refrigerator test system, which can measure up to eight 1x32 arrays simultaneously using a time-division multiplexer, as well as our single-pixel test system which can measure down to 15mK. In our previous Ir array measurements our best reported performance was NEP=2.5x10(exp -19) W/Hz(1/2) and tapprox.5ms for straight-beam TESs. In fact, we expected NEPapprox.1.5x10(exp -19)W/Hz(1/2) for meander beam TESs, but did not achieve this previously due to 1/f noise. Here, we detail improvements toward measuring the expected NEP and demonstrate NEP=(1.3+0.2)x10(exp -19)W/Hz(1/2) in our single-pixel test system and NEP=(1.6+0.3)x10(exp -19)W/Hz(1/2) in our array test system.
Development of Fast, Background-Limited Transition-Edge Sensors for the Background-Limited Infrared/Sub-mm Spectrograph (BLISS) for SPICA
We report experimental progress toward demonstrating background-limited arrays of membrane-isolated transition-edge sensors (TESs) for the Background Limited Infrared/Sub-mm Spectrograph (BLISS). BLISS is a space-borne instrument with grating spectrometers for wavelengths lambda=35-435 micron and with R=lambda/delta lambda approximately equals 500. The goals for BLISS TESs are: noise equivalent power (NEP) = 5x10 (sup -20) W/Hz(exp 1/2) and response time tau <30ms. We expect background-limited performance from bilayers TESs with T(sub c) = 65mK and G=15fW/K. However, such TESs cannot be operated at 50mK unless stray power on the devices, or dark power P(sub D), is less than 200aW. We describe criteria for measuring P(sub D) that requires accurate knowledge of TC. Ultimately, we fabricated superconducting thermistors from Ir (T(sub c) >= 135mK) and Mo/Cu proximitized bilayers, where T(sub c) is the thermistor transition temperature. We measured the Ir TES arrays in our 50mK adiabatic demagnetization refrigerator test system, which can measure up to eight 1x32 arrays simultaneously using a time-division multiplexer, as well as our single-pixel test system which can measure down to 15mK. In our previous Ir array measurements our best reported performance was NEP=2.5x10(exp -19) W/Hz(sub 1/2) and Tau approximately equals 5ms for straight-beam TESs. In fact, we expected NEP approximately equals 1.5x10(exp -19)?W/Hz(sup 1/2) for meander beam TESs, but did not achieve this previously due to 1/f noise. Here, we detail improvements toward measuring the expected NEP and demonstrate NEP=(1.3+0.2)x10 (sup -19)W/Hz(exp 1/2) in our single-pixel test system and NEP=(1.6+/-0.3)x10(sup -19)W/Hz(sup 1/2) in our array test system.
Achieving BLISS: Challenges for Building Fast, Ultra-Sensitive Transition-Edge Sensors
Topics: 1.Motivation and Intro to TESs. 2. BLISS Specifications-tolerance to dark power. 3.Measuring stray (dark) power-Tc (alpha) and G measurements. a) Overview two methods: JTD vs. TES. b) TES arrays: measurement and complications for Pd, Tc, and alpha. 4. Results: Pd compare, NEP, tau, 1/f issues. LIRGs and ULIRGs: Excellent example of distinct optical/UV and IR luminosity. Interaction long known, but huge luminosity is not predicted based on optical studies. (greater than 90% of the energy is emitted at in the far-IR). Large luminosity has both starburst and accretion components.
Recent Results of a New Microwave SQUID Multiplexer
We are developing a proof-of-concept microwave SQUID multiplexer containing four SQUIDs coupled to GHz frequency resonant circuits and fed with a single microwave readout line. The resonators are half-wave coplanar waveguide sections and are similar to the structures used for the microwave kinetic inductance detectors developed in our group. Optimal values for the interdigital gap capacitors were determined to maximize the sensitivity of the transmitted and reflected microwave signal with respect to changes in the dynamic resistance of the SQUID. The dc current-bias line for the SQUID has an in-line inductive high frequency filter to minimize coupling between the bias line and resonator. A high frequency modulation scheme is proposed to eliminate the need for individual flux biasing of the SQUIDs, which extends the dynamic range of the readout. In this scheme a common modulation signal is imposed on each SQUID and the received signal is demodulated at one and two times the modulation frequency to maintain sensitivity at any flux state. We present the recent results of the microwave SQUID multiplexer system operating at a readout frequency range of 10 - 11GHz.
THz Instrumentation for the Herschel Space Observatory's Heterodyne Instrument for Far Infrared
The Heterodyne Instrument for Far Infrared (HIFI) on ESA's Herschel Space Observatory utilizes a variety of novel RF components in its five SIS receiver channels covering 480-1250 GHz and two HEB receiver channels covering 1410-1910 GHz. The local oscillator unit will be passively cooled while the focal plane unit is cooled by superfluid helium and cold helium vapors. HIFI employs W-band GaAs amplifiers, InP HEMT low noise IF amplifiers, fixed tuned broadband planar diode multipliers, high power W-bapd Isolators, and novel material systems in the SIS mixers. The National Aeronautics and Space Administration through the Jet Propulsion Laboratory is managing the development of the highest frequency (1119-1250 GHz) SIS mixers, the local oscillators oscillators for the three highest frequency receivers as well as W-band power amplifiers, high power W-band isolators, varactor diode devices for all high frequency multipliers and InP HEMT components for all the receiver channels intermediate frequency amplifiers. The NASA developed components represent a significant advancement in the available performance. This paper presents an update of the performance and the current state of development.
Possible transition-edge operation of diffusion-cooled hot-electron bolometers
Explore the source record for details and available documents.
Tantalum hot-electron bolometers for heterodyne receivers
Explore the source record for details and available documents.
1.8 THz superconductive hot-electron bolometer mixer for Herschel
Explore the source record for details and available documents.
Diffusion-cooled tantalum bolometers for heterodyne mixers
Explore the source record for details and available documents.