Engineering Papers⌕ Search

Engineering topics

Bucci, C.

Publications and source records attributed to Bucci, C..

At least 19 records

Data-driven background model for the CUORE experiment

Here, we present the model we developed to reconstruct the CUORE radioactive background based on the analysis of an experimental exposure of 1038.4 kg yr. The data reconstruction relies on a simultaneous Bayesian fit applied to energy spectra over a broad energy range. The high granularity of the CUORE detector, together with the large exposure and extended stable operations, allow for an in-depth exploration of both spatial and time dependence of backgrounds. We achieve high sensitivity to both bulk and surface activities of the materials of the setup, detecting levels as low as 10 nBq kg −1 and 0.1 nBq cm −2 , respectively. We compare the contamination levels we extract from the background model with prior radio-assay data, which informs future background risk mitigation strategies. The results of this background model play a crucial role in constructing the background budget for the CUPID experiment as it will exploit the same CUORE infrastructure.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat

CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of 100 Mo. It will operate at ~10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of 100 Mo-enriched Li 2 MoO 4 crystals, facing thin Ge-wafer-based bolometric light detectors. In the CUPID design, the detector structure is novel and needs to be validated. In particular, the CUORE cryostat presents a high level of mechanical vibrations due to the use of pulse tubes and the effect of vibrations on the detector performance must be investigated. In this paper we report the first test of the CUPID-design bolometric light detectors with NTD-Ge sensors in a dilution refrigerator equipped with a pulse tube in an above-ground lab. Light detectors are characterized in terms of sensitivity, energy resolution, pulse time constants, and noise power spectrum. Despite the challenging noisy environment due to pulse-tube-induced vibrations, we demonstrate that all the four tested light detectors comply with the CUPID goal in terms of intrinsic energy resolution of 100 eV RMS baseline noise. Indeed, we have measured 70–90 eV RMS for the four devices, which show an excellent reproducibility. We have also obtained high energy resolutions at the 356 keV line from a 133 Ba source, as good as Ge semiconductor γ detectors in this energy range.

47 OTHER INSTRUMENTATION↗

Twelve-crystal prototype of Li 2 MoO 4 scintillating bolometers for CUPID and CROSS experiments

An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied depending on the size of phonon NTD-Ge sensors glued to both LMO and Ge absorbers, shape of the Ge light detectors (circular vs. square, from two suppliers), in different light collection conditions (with and without reflector, with aluminum coated LMO crystal surface). The scintillating bolometer array was operated over 8 months in the low-background conditions that allowed to probe a very low, μBq/kg, level of the LMO crystals radioactive contamination by 228 Th and 226 Ra.

47 OTHER INSTRUMENTATION↗

CUPID: The Next-Generation Neutrinoless Double Beta Decay Experiment

We report CUPID is a next-generation tonne-scale bolometric neutrinoless double beta decay experiment that will probe the Majorana nature of neutrinos and discover lepton number violation in case of observation of this singular process. CUPID will be built on experience, expertise and lessons learned in CUORE and will be installed in the current CUORE infra-structure in the Gran Sasso underground laboratory. The CUPID detector technology, successfully tested in the CUPID-Mo experiment, is based on scintillating bolometers of Li 2 MoO 4 enriched in the isotope of interest 100 Mo. In order to achieve its ambitious science goals, the CUPID collaboration aims to reduce the backgrounds in the region of interest by a factor 100 with respect to CUORE. This performance will be achieved by introducing the high efficient α/β discrimination demonstrated by the CUPID-0 and CUPID-Mo experiments, and using a high transition energy double beta decay nucleus such as 100 Mo to minimize the impact of the gamma background. CUPID will consist of about 1500 hybrid heat-light detectors for a total isotope mass of 250 kg. The CUPID scientific reach is supported by a detailed and safe background model based on CUORE, CUPID-Mo and CUPID-0 results. The required performances have already been demonstrated and will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An energy-dependent electro-thermal response model of CUORE cryogenic calorimeter

The Cryogenic Underground Observatory for Rare Events (CUORE) is the most sensitive experiment searching for neutrinoless double-beta decay (0νββ) in 130 Te. CUORE uses a cryogenic array of 988 TeO 2 calorimeters operated at ~10 mK with a total mass of 741 kg. To further increase the sensitivity, the detector response must be well understood. Here, we present a non-linear thermal model for the CUORE experiment on a detector-by-detector basis. We have examined both equilibrium and dynamic electro-thermal models of detectors by numerically fitting non-linear differential equations to the detector data of a subset of CUORE channels which are well characterized and representative of all channels. Further, we demonstrate that the hot-electron effect and electric-field dependence of resistance in NTD-Ge thermistors alone are inadequate to describe our detectors' energy-dependent pulse shapes. We introduce an empirical second-order correction factor in the exponential temperature dependence of the thermistor, which produces excellent agreement with energy-dependent pulse shape data up to 6 MeV. We also present a noise analysis using the fitted thermal parameters and show that the intrinsic thermal noise is negligible compared to the observed noise for our detectors.

47 OTHER INSTRUMENTATION↗

Latest Results from the CUORE Experiment

Abstract The Cryogenic Underground Observatory for Rare Events (CUORE) is the first cryogenic experiment searching for $$0\nu \beta \beta $$ 0 ν β β decay that has been able to reach the one-tonne mass scale. The detector, located at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy, consists of an array of 988 $${\mathrm{TeO}}_{2}$$ TeO 2 crystals arranged in a compact cylindrical structure of 19 towers. CUORE began its first physics data run in 2017 at a base temperature of about 10 mK and in April 2021 released its $$3{\mathrm{rd}}$$ 3 rd result of the search for $$0\nu \beta \beta $$ 0 ν β β , corresponding to a tonne-year of $$\mathrm{TeO}_{2}$$ TeO 2 exposure. This is the largest amount of data ever acquired with a solid state detector and the most sensitive measurement of $$0\nu \beta \beta $$ 0 ν β β decay in $${}^{130}\mathrm{Te}$$ 130 Te ever conducted . We present the current status of CUORE search for $$0\nu \beta \beta $$ 0 ν β β with the updated statistics of one tonne-yr. We finally give an update of the CUORE background model and the measurement of the $${}^{130}\mathrm{Te}$$ 130 Te $$2\nu \beta \beta $$ 2 ν β β decay half-life and decay to excited states of $${}^{130}\mathrm{Xe}$$ 130 Xe , studies performed using an exposure of 300.7 kg yr.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimization of the first CUPID detector module

CUPID will be a next generation experiment searching for the neutrinoless double β decay, whose discovery would establish the Majorana nature of the neutrino. Based on the experience achieved with the CUORE experiment, presently taking data at LNGS, CUPID aims to reach a background free environment by means of scintillating Li 2 100 MoO 4 crystals coupled to light detectors. Indeed, the simultaneous heat and light detection allows us to reject the dominant background of α particles, as proven by the CUPID-0 and CUPID-Mo demonstrators. In this work we present the results of the first test of the CUPID baseline module. In particular, we propose a new optimized detector structure and light sensors design to enhance the engineering and the light collection, respectively. We characterized the heat detectors, achieving an energy resolution of (5.9 ± 0.2) keV FWHM at the Q-value of 100 Mo (about 3034 keV). We studied the light collection of the baseline CUPID design with respect to an alternative configuration which features gravity-assisted light detectors’ mounting. In both cases we obtained an improvement in the light collection with respect to past measures and we validated the particle identification capability of the detector, which ensures an α particle rejection higher than 99.9%, fully satisfying the requirements for CUPID.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Machine Learning Techniques for Pile-Up Rejection in Cryogenic Calorimeters

CUORE Upgrade with Particle IDentification (CUPID) is a foreseen ton-scale array of Li 2 MoO 4 (LMO) cryogenic calorimeters with double readout of heat and light signals. Its scientific goal is to fully explore the inverted hierarchy of neutrino masses in the search for neutrinoless double beta decay of 100 Mo. Pile-up of standard double beta decay of the candidate isotope is a relevant background. We generate pile-up heat events via injection of Joule heater pulses with a programmable waveform generator in a small array of LMO crystals operated underground in the Laboratori Nazionali del Gran Sasso, Italy. This allows to label pile-up pulses and control both time difference and underlying amplitudes of individual heat pulses in the data. We present the performance of supervised learning classifiers on data and the attained pile-up rejection efficiency.

47 OTHER INSTRUMENTATION↗

Search for Majorana neutrinos exploiting millikelvin cryogenics with CUORE

The possibility that neutrinos may be their own antiparticles, unique among the known fundamental particles, arises from the symmetric theory of fermions proposed by Ettore Majorana in 1937. Given the profound consequences of such Majorana neutrinos, among which is a potential explanation for the matter–antimatter asymmetry of the universe via leptogenesis, the Majorana nature of neutrinos commands intense experimental scrutiny globally; one of the primary experimental probes is neutrinoless double beta (0νββ) decay. Here we show results from the search for 0νββ decay of 130 Te, using the latest advanced cryogenic calorimeters with the CUORE experiment3. CUORE, operating just 10 millikelvin above absolute zero, has pushed the state of the art on three frontiers: the sheer mass held at such ultralow temperatures, operational longevity, and the low levels of ionizing radiation emanating from the cryogenic infrastructure. We find no evidence for 0νββ decay and set a lower bound of the process half-life as 2.2 × 10 25 years at a 90 percent credibility interval. We discuss potential applications of the advances made with CUORE to other fields such as direct dark matter, neutrino and nuclear physics searches and large-scale quantum computing, which can benefit from sustained operation of large payloads in a low-radioactivity, ultralow-temperature cryogenic environment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New results from the CUORE experiment

We report that the Cryogenic Underground Observatory for Rare Events (CUORE) is the first bolometric experiment searching for neutrino-less double-beta (0vββ) decay that has been able to reach the one-ton scale. The detector, located at the Laboratori Nazionali del Gran Sasso in Italy, consists of an array of 988 TeO 2 crystals arranged in a compact cylindrical structure of 19 towers. Following the completion of the detector construction in August 2016, CUORE began its first physics data run in 2017 at a base temperature of about 10 mK. Following multiple optimization campaigns in 2018, CUORE is currently in stable operating mode. In 2019, CUORE released its second result of the search for 0vββ corresponding to a TeO 2 exposure of 372.5 kg∙yr and a median exclusion sensitivity to a 130 Te 0vββ decay half-life of 1.7 ∙ 10 25 yr. We find no evidence for 0vββ decay and set a 90% C.I. Bayesian lower limit of 3.2 ∙ 10 25 yr on the 130 Te 0vββ decay half-life. We present the current status of CUORE’s search for 0vββ. We give an update of the CUORE background model and the measurement of the 130 Te two neutrino double-beta (2vββ) decay half-life. Eventually, we show the preliminary results on half-life limits from the analysis of 130 Te 0vββ and 2vββ decay to the first 0 + excited state of 130 Xe.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimization of a single module of CUPID

CUPID is the next generation experiment which will use scintillating cryogenic calorimeters to search for the neutrinoless double β decay. This unobserved process would shed light on the nature of the neutrino, which up to our knowledge could be a Majorana or a Dirac particle, and would give us an important hint to explain the lack of antimatter in the universe. This ambitious search needs a detector with unique characteristics such as an extremely low background level and an excellent energy resolution. CUPID is now in advanced R&D state to optimize the detector design in order to completely exploit the potentialities of scintillating cryogenic calorimeters. In the following I will describe the test performed at the LNGS (Laboratori Nazionali del Gran Sasso) of a single module of the future CUPID detector. In this contribution we present the performance obtained with a novel assembly concept, proving that it matches the requirements for CUPID.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Searching for New Physics in two-neutrino double beta decay with CUPID

In the past few years, attention has been drawn to the fact that a precision analysis of two-neutrino double beta decay (2υββ) allows the study of interesting physics cases like the emission of Majoron bosons and possible Lorentz symmetry violation. These processes modify the summed-energy distribution of the two electrons emitted in 2υββ. CUPID is a next-generation experiment aiming to exploit 100 Mo-enriched scintillating Li 2 MoO 4 crystals, operating as cryogenic calorimeters. Given the relatively fast half-life of 100 Mo 2υββ and the large exposure that can be reached by CUPID, we expect to measure with very high precision the 100 Mo 2υββ spectrum shape, reaching great sensitivities in the search for distortions induced by the physics beyond the Standard Model. In this contribution, we present the CUPID exclusion sensitivity for such New Physics processes, as well as the preliminary projected background of CUPID.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CUORE opens the door to tonne-scale cryogenics experiments

The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution – comparable to semiconductor detectors – and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require ever greater exposures, which has driven them to ever larger cryogenic detectors, with the CUORE experiment being the first to reach a tonne-scale, mK-cooled, experimental mass. CUORE, designed to search for neutrinoless double beta decay, has been operational since 2017 at a temperature of about 10 mK. This result has been attained by the use of an unprecedentedly large cryogenic infrastructure called the CUORE cryostat: conceived, designed and commissioned for this purpose. In this article the main characteristics and features of the cryogenic facility developed for the CUORE experiment are highlighted. In this work, a brief introduction of the evolution of the field and of the past cryogenic facilities are given. The motivation behind the design and development of the CUORE cryogenic facility is detailed as are the steps taken toward realization, commissioning, and operation of the CUORE cryostat. The major challenges overcome by the collaboration and the solutions implemented throughout the building of the cryogenic facility will be discussed along with the potential improvements for future facilities. The success of CUORE has opened the door to a new generation of large-scale cryogenic facilities in numerous fields of science. Broader implications of the incredible feat achieved by the CUORE collaboration on the future cryogenic facilities in various fields ranging from neutrino and dark matter experiments to quantum computing will be examined.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Background identification in cryogenic calorimeters through $\alpha -\alpha$ delayed coincidences

Localization and modeling of radioactive contaminations is a challenge that ultra-low background experiments are constantly facing. These are fundamental steps both to extract scientific results and to further reduce the background of the detectors. Here we present an innovative technique based on the analysis of $\alpha -\alpha$ delayed coincidences in 232 Th and 238 U decay chains, developed to investigate the contaminations of the ZnSe crystals in the CUPID-0 experiment. This method allows to disentangle surface and bulk contaminations of the detectors relying on the different probability to tag delayed coincidences as function of the $\alpha$ decay position.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Novel technique for the study of pileup events in cryogenic bolometers

Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such as CUPID, in order to reject background due to pile-up of two-neutrino double-beta decay events. In this paper, we describe a technique developed to study the pile-up rejection capability of cryogenic bolometers. Our approach, which consists of producing controlled pile-up events with a programmable waveform generator, has the benefit that we can reliably and reproducibly control the time separation and relative energy of the individual components of the generated pile-up events. The resulting data allow us to optimize and benchmark analysis strategies to discriminate between individual and pile-up pulses. We describe a test of this technique performed with a small array of detectors at the Laboratori Nazionali del Gran Sasso, in Italy; we obtain a 90% rejection efficiency against pulser-generated pile-up events with rise time of ~15 ms down to time separation between the individual events of 2 ms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Search for double-beta decay of $$\mathrm {^{130}Te}$$ to the $$0^+$$ states of $$\mathrm {^{130}Xe}$$ with CUORE

Abstract The CUORE experiment is a large bolometric array searching for the lepton number violating neutrino-less double beta decay ( $$0\nu \beta \beta $$ 0 ν β β ) in the isotope $$\mathrm {^{130}Te}$$ 130 Te . In this work we present the latest results on two searches for the double beta decay (DBD) of $$\mathrm {^{130}Te}$$ 130 Te to the first $$0^{+}_2$$ 0 2 + excited state of $$\mathrm {^{130}Xe}$$ 130 Xe : the $$0\nu \beta \beta $$ 0 ν β β decay and the Standard Model-allowed two-neutrinos double beta decay ( $$2\nu \beta \beta $$ 2 ν β β ). Both searches are based on a 372.5 kg $$\times $$ × yr TeO $$_2$$ 2 exposure. The de-excitation gamma rays emitted by the excited Xe nucleus in the final state yield a unique signature, which can be searched for with low background by studying coincident events in two or more bolometers. The closely packed arrangement of the CUORE crystals constitutes a significant advantage in this regard. The median limit setting sensitivities at 90% Credible Interval (C.I.) of the given searches were estimated as $$\mathrm {S^{0\nu }_{1/2} = 5.6 \times 10^{24} \, \mathrm {yr}}$$ S 1 / 2 0 ν = 5.6 × 10 24 yr for the $${0\nu \beta \beta }$$ 0 ν β β decay and $$\mathrm {S^{2\nu }_{1/2} = 2.1 \times 10^{24} \, \mathrm {yr}}$$ S 1 / 2 2 ν = 2.1 × 10 24 yr for the $${2\nu \beta \beta }$$ 2 ν β β decay. No significant evidence for either of the decay modes was observed and a Bayesian lower bound at $$90\%$$ 90 % C.I. on the decay half lives is obtained as: $$\mathrm {(T_{1/2})^{0\nu }_{0^+_2} > 5.9 \times 10^{24} \, \mathrm {yr}}$$ ( T 1 / 2 ) 0 2 + 0 ν > 5.9 × 10 24 yr for the $$0\nu \beta \beta $$ 0 ν β β mode and $$\mathrm {(T_{1/2})^{2\nu }_{0^+_2} > 1.3 \times 10^{24} \, \mathrm {yr}}$$ ( T 1 / 2 ) 0 2 + 2 ν > 1.3 × 10 24 yr for the $$2\nu \beta \beta $$ 2 ν β β mode. These represent the most stringent limits on the DBD of $$^{130}$$ 130 Te to excited states and improve by a factor $$\sim 5$$ ∼ 5 the previous results on this process.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗