Detailed analysis of a waked turbine using a high-resolution scanning lidar.
Abstract not provided.
Engineering topics
Publications and source records attributed to Bryant, Joshua.
Abstract not provided.
The Scaled Wind Farm Technology (SWiFT) facility, operated by Sandia National Laboratories for the U.S. Department of Energy's Wind and Water Power Program, is a wind energy research site with multiple wind turbines scaled for the experimental study of wake dynamics, advanced rotor development, turbine control, and advanced sensing for production-scale wind farms. The SWiFT site currently includes three variable-speed, pitch-regulated, three-bladed wind turbines. The six volumes of this manual provide a detailed description of the SWiFT wind turbines, including their operation and user interfaces, electrical and mechanical systems, assembly and commissioning procedures, and safety systems.
Purpose: Cone-beam computed tomographic images (CBCTs) are increasingly used for setup correction, soft tissue targeting, and image-guided adaptive radiotherapy. However, CBCT image quality is limited by low contrast and imaging artifacts. This analysis investigates the detectability of soft tissue boundaries in CBCT by performing a multiple-observer segmentation study. Methods and Materials: In four prostate cancer patients prostate, bladder and rectum were repeatedly delineated by five observers on CBCTs and fan-beam CTs (FBCTs). A volumetric analysis of contouring variations was performed by calculating coefficients of variation (COV: standard deviation/average volume). The topographical distribution of contouring variations was analyzed using an average surface mesh-based method. Results: Observer- and patient-averaged COVs for FBCT/CBCT were 0.09/0.19 for prostate, 0.05/0.08 for bladder, and 0.09/0.08 for rectum. Contouring variations on FBCT were significantly smaller than on CBCT for prostate (p < 0.03) and bladder (p < 0.04), but not for rectum (p < 0.37; intermodality differences). Intraobserver variations from repeated contouring of the same image set were not significant for either FBCT or CBCT (p < 0.05). Average standard deviations of individual observers' contour differences from average surface meshes on FBCT vs. CBCT were 1.5 vs. 2.1 mm for prostate, 0.7 vs. 1.4 mm for bladder, and 1.3 vs. 1.5 mm for rectum. The topographical distribution of contouring variations was similar for FBCT and CBCT. Conclusion: Contouring variations were larger on CBCT than FBCT, except for rectum. Given the well-documented uncertainty in soft tissue contouring in the pelvis, improvement of CBCT image quality and establishment of well-defined soft tissue identification rules are desirable for image-guided radiotherapy.