Engineering Papers⌕ Search

Engineering topics

Bruker, M. W.

Publications and source records attributed to Bruker, M. W..

New Results at JLab Describing Operating Lifetime of GaAs Photo-guns

Po­lar­ized elec­trons from GaAs pho­to­cath­odes have been key to some of the high­est-im­pact re­sults of the Jef­fer­son Lab sci­ence pro­gram over the past 30 years. Dur­ing this time, var­i­ous stud­ies have given in­sight into im­prov­ing the op­er­a­tional life­time of these pho­to­cath­odes in DC high-volt­age photo-guns while using lasers with spa­tial Gauss­ian pro­files of typ­i­cally 0.5 mm to 1 mm FWHM, cath­ode volt­ages of 100 kV to 130 kV, and a wide range of beam cur­rents up to mul­ti­ple mA. In this con­tri­bu­tion, we show re­cent ex­per­i­men­tal data from a 100 kV to 180 kV setup and de­scribe our progress at pre­dict­ing the life­time based on the cal­cu­la­ble dy­nam­ics of ion­ized gas mol­e­cules in­side the gun. These new ex­per­i­men­tal stud­ies at Jef­fer­son Lab are specif­i­cally aimed at ex­plor­ing the ion dam­age of higher-volt­age guns being built for in­jec­tors.

Bruker, M. W.↗

Operational Experience of the New Booster Cryomodule at the Upgraded Injector Test Facility

Since the early 1990s, the in­jec­tor of the CEBAF ac­cel­er­a­tor at Jef­fer­son Lab has re­lied on a nor­mal-con­duct­ing RF graded-beta cap­ture sec­tion to boost the ki­netic en­ergy of the elec­tron beam from 100 / 130 keV to 600 keV for sub­se­quent ac­cel­er­a­tion using a cry­omod­ule hous­ing two su­per­con­duct­ing 5-cell cav­i­ties sim­i­lar to those used through­out the ac­cel­er­a­tor. To sim­plify the in­jec­tor de­sign and im­prove the beam qual­ity, the nor­mal-con­duct­ing RF cap­ture sec­tion and the cry­omod­ule will be re­placed with a new sin­gle booster cry­omod­ule em­ploy­ing a su­per­con­duct­ing, β = 0.6, 2-cell-cav­ity cap­ture sec­tion and a sin­gle, β = 0.97, 7-cell cav­ity. The Up­graded In­jec­tor Test Fa­cil­ity at Jef­fer­son Lab is cur­rently host­ing the new cry­omod­ule to eval­u­ate its per­for­mance with beam be­fore in­stal­la­tion at CEBAF. While demon­strat­ing sat­is­fac­tory per­for­mance of the booster and good agree­ment with sim­u­la­tions, our beam test re­sults also speak to lim­i­ta­tions of ac­cel­er­a­tor op­er­a­tions in a noisy, ther­mally un­reg­u­lated en­vi­ron­ment.

Bruker, M. W.↗

Bunch Length Measurements at the CEBAF Injector at 130 kV

In this work, we investigated the evolution in bunch length of beams through the CEBAF injector for 8?770 fC charge per bunch. Using the software General Particle Tracer (GPT), we have simulated beams through the beamline of the CEBAF injector to predict bunch lengths at the location of a beam chopper for comparison with measurements and to validate the model. We performed these simulations with the existing injector using a 130 kV gun voltage. The mea- surements have been done using chopper phase scanning technique for two injector laser drive frequencies 499 MHz and 249.5 MHz. Acknowledgement This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics under contract DE-AC05-06OR23177.

Pokharel, S.↗

pyJSPEC - A Python Module for IBS and Electron Cooling Simulation

The intrabeam scattering is an important collective effect that can deteriorate the property of a high-intensity beam and electron cooling is a method to mitigate the IBS effect. JSPEC (JLab Simulation Package on Electron Cooling) is an open-source C++ program developed at Jefferson Lab, which simulates the evolution of the ion beam under the IBS and/or the electron cooling effect. The Python wrapper of the C++ code, pyJSPEC, for Python 3.x environment has been recently developed and released. It allows the users to run JSPEC simulations in a Python environment. It also makes it possible for JSPEC to collaborate with other accelerator and beam modeling programs as well as plentiful python tools in data visualization, optimization, machine learning, etc. In this paper, we will introduce the features of pyJSPEC and demonstrate how to use it with sample codes and numerical results.

Zhang, H.↗

Manufacturing the Harmonic Kicker Cavity Prototype for the Electron-Ion Collider

High-bunch-frequency beam-separation schemes, such as the injection scheme proposed for the Rapid Cycling Synchrotron at the Electron-Ion Collider, demand rise and fall times an order of magnitude below what can realistically be accomplished with a stripline kicker. Nanosecond-time-scale kick waveforms can instead be obtained by Fourier synthesis in a harmonically resonant quarter-wave radio-frequency cavity which is optimized for high shunt impedance. Originally developed for the Jefferson Lab Electron-Ion Collider (JLEIC) Circulator Cooler Ring, a hypothetical 11-pass ring driven by an energy-recovery linac at Jefferson Lab, our high-power prototype of such a harmonic kicker cavity, which operates at five modes at the same time, will demonstrate the viability of this concept with a beam test at Jefferson Lab. As the geometry of the cavity, tight mechanical tolerances, and number of ports complicate the design and manufacturing process, special care must be given to the order of the manufacturing steps. We present our experiences with the manufacturability of the present design, lessons learned, and first RF test results from the prototype.

Overstreet, S. A.↗

Manufacturing the Harmonic Kicker Cavity Prototype for the Electron-Ion Collider

High-bunch-frequency beam-separation schemes, such as the injection scheme proposed for the Rapid Cycling Synchrotron at the Electron-Ion Collider, demand rise and fall times an order of magnitude below what can realistically be accomplished with a stripline kicker. Nanosecond-time-scale kick waveforms can instead be obtained by Fourier synthesis in a harmonically resonant quarter-wave radio-frequency cavity which is optimized for high shunt impedance. Originally developed for the Jefferson Lab Electron-Ion Collider (JLEIC) Circulator Cooler Ring, a hypothetical 11-pass ring driven by an energy-recovery linac at Jefferson Lab, our high-power prototype of such a harmonic kicker cavity, which operates at five modes at the same time, will demonstrate the viability of this concept with a beam test at Jefferson Lab. As the geometry of the cavity, tight mechanical tolerances, and number of ports complicate the design and manufacturing process, special care must be given to the order of the manufacturing steps. We present our experiences with the manufacturability of the present design, lessons learned, and first RF test results from the prototype.

Overstreet, S. A.↗

New Results at JLab Describing Operating Lifetime of GaAs Photo-guns

Po­lar­ized elec­trons from GaAs pho­to­cath­odes have been key to some of the high­est-im­pact re­sults of the Jef­fer­son Lab sci­ence pro­gram over the past 30 years. Dur­ing this time, var­i­ous stud­ies have given in­sight into im­prov­ing the op­er­a­tional life­time of these pho­to­cath­odes in DC high-volt­age photo-guns while using lasers with spa­tial Gauss­ian pro­files of typ­i­cally 0.5 mm to 1 mm FWHM, cath­ode volt­ages of 100 kV to 130 kV, and a wide range of beam cur­rents up to mul­ti­ple mA. In this con­tri­bu­tion, we show re­cent ex­per­i­men­tal data from a 100 kV to 180 kV setup and de­scribe our progress at pre­dict­ing the life­time based on the cal­cu­la­ble dy­nam­ics of ion­ized gas mol­e­cules in­side the gun. These new ex­per­i­men­tal stud­ies at Jef­fer­son Lab are specif­i­cally aimed at ex­plor­ing the ion dam­age of higher-volt­age guns being built for in­jec­tors.

Bruker, M. W.↗

Operational Experience of the New Booster Cryomodule at the Upgraded Injector Test Facility

Since the early 1990s, the in­jec­tor of the CEBAF ac­cel­er­a­tor at Jef­fer­son Lab has re­lied on a nor­mal-con­duct­ing RF graded-beta cap­ture sec­tion to boost the ki­netic en­ergy of the elec­tron beam from 100 / 130 keV to 600 keV for sub­se­quent ac­cel­er­a­tion using a cry­omod­ule hous­ing two su­per­con­duct­ing 5-cell cav­i­ties sim­i­lar to those used through­out the ac­cel­er­a­tor. To sim­plify the in­jec­tor de­sign and im­prove the beam qual­ity, the nor­mal-con­duct­ing RF cap­ture sec­tion and the cry­omod­ule will be re­placed with a new sin­gle booster cry­omod­ule em­ploy­ing a su­per­con­duct­ing, β = 0.6, 2-cell-cav­ity cap­ture sec­tion and a sin­gle, β = 0.97, 7-cell cav­ity. The Up­graded In­jec­tor Test Fa­cil­ity at Jef­fer­son Lab is cur­rently host­ing the new cry­omod­ule to eval­u­ate its per­for­mance with beam be­fore in­stal­la­tion at CEBAF. While demon­strat­ing sat­is­fac­tory per­for­mance of the booster and good agree­ment with sim­u­la­tions, our beam test re­sults also speak to lim­i­ta­tions of ac­cel­er­a­tor op­er­a­tions in a noisy, ther­mally un­reg­u­lated en­vi­ron­ment.

Bruker, M. W.↗

JSPEC: A Program for IBS and Electron Cooling Simulation

Intrabeam scattering is an important collective effect that can deteriorate the properties of a high-intensity beam, and electron cooling is a method to mitigate the IBS effect. JSPEC (JLab Simulation Package for Electron Cooling) is an open-source program developed at Jefferson Lab, which simulates the evolution of the ion beam under the IBS and/or the electron cooling effect. JSPEC has been benchmarked with BETACOOL and experimental data. In this report, we will introduce the features of JSPEC, including the friction force calculation, the IBS expansion rate and electron cooling rate calculation, and the beam-dynamic simulations for the electron cooling process; explain how to set up the simulations in JSPEC; and demonstrate the benchmarking results.

Zhang, He↗

Demonstration of Electron Cooling using a Pulsed Beam from an Electrostatic Electron Cooler

Electron cooling continues to be an invaluable technique to reduce and maintain the emittance in hadron storage rings in cases where stochastic cooling is inefficient and radiative cooling is negligible. Extending the energy range of electron coolers beyond what is feasible with the conventional, electrostatic approach necessitates the use of RF fields for acceleration and, thus, a bunched electron beam. To experimentally investigate how the relative time structure of the two beams affects the cooling properties, we have set up a pulsed-beam cooling device by adding a synchronized pulsing circuit to the conventional electron source of the CSRm cooler at Institute of Modern Physics *. We show the effect of the electron bunch length and longitudinal ion focusing strength on the temporal evolution of the longitudinal and transverse ion beam profile and demonstrate the detrimental effect of timing jitter as predicted by theory and simulations. Compared to actual RF-based coolers, the simplicity and flexibility of our setup will facilitate further investigations of specific aspects of bunched cooling such as synchro-betatron coupling and phase dithering.

Bruker, M. W.↗

RF Harmonic Kicker R&D Demonstration and Its Application to the RCS Injection of the EIC

The Rapid Cycling Synchrotron (RCS) of the Electron-Ion Collider (EIC) at Brookhaven National Laboratory (BNL) is an accelerating component of the electron injection complex, which provides polarized electrons in electron-ion collisions in the main Electron Storage Ring (ESR). We present the injection scheme into the RCS based on an ultra-fast harmonic kicker, whose "five odd-harmonic modes" prototype was developed in the context of the Jefferson Lab EIC (JLEIC) conceptual design. In its early stage of R&D, the sharp (~3 ns width) waveform construction, beam dynamics, and pulsed power operation with short ramping time (~10 us) will be discussed together with the fabrication work of the JLEIC prototype.

Park, G. -T.↗

Demonstration of Electron Cooling using a Pulsed Beam from an Electrostatic Electron Cooler

Electron cooling continues to be an invaluable technique to reduce and maintain the emittance in hadron storage rings in cases where stochastic cooling is inefficient and radiative cooling is negligible. Extending the energy range of electron coolers beyond what is feasible with the conventional, electrostatic approach necessitates the use of RF fields for acceleration and, thus, a bunched electron beam. To experimentally investigate how the relative time structure of the two beams affects the cooling properties, we have set up a pulsed-beam cooling device by adding a synchronized pulsing circuit to the conventional electron source of the CSRm cooler at Institute of Modern Physics *. We show the effect of the electron bunch length and longitudinal ion focusing strength on the temporal evolution of the longitudinal and transverse ion beam profile and demonstrate the detrimental effect of timing jitter as predicted by theory and simulations. Compared to actual RF-based coolers, the simplicity and flexibility of our setup will facilitate further investigations of specific aspects of bunched cooling such as synchro-betatron coupling and phase dithering.

Bruker, M. W.↗