Engineering Papers⌕ Search

Engineering topics

Bruegge, Carol J.

Publications and source records attributed to Bruegge, Carol J..

At least 19 records

Multi-Angle Imager for Aerosols (MAIA) spectral and radiometric calibration

The Multi-angle Imaging SpectroRadiometer (MISR) was launched as part of NASA’s Terra satellite suite of instruments. Still operational, it makes use of observations from multiple view angles to retrieve aerosol abundance and particle properties. The Multi-Angle Imager for Aerosols (MAIA) instrument improves on this heritage by incorporating polarimetry and an expanded spectral range. Combining these data with surface measurements, the relationship between pollution and human health will be explored. MAIA has just completed camera testing, building on the experience from MISR. Spectral calibration now makes use of a double subtractive monochromator, built with the intent to allow the exit slit output to be uniform in spectral content. For radiometric testing, hardware upgrades have included adding UV lamps to the 1.65 cm (65") integrating sphere, use of a NIST-traceable sphere to establish absolute radiances, and the addition of a UV transfer spectrometer to support characterization of the sphere output from 300 to 2500 nm. During camera build, Newton’s rings were observed in the detector Quantum Efficiency (QE) measurements. This is due to etaloning within the detector itself. Etaloning was also evident in the spectral and radiometric characterizations performed on the completed camera. Spectral metrics, including center wavelength and width, are presented here using a moment’s analysis. This better represents the band properties, particularly in bands where fringing is observed, as compared to a full-width at half-maximum determination. It is believed that the MAIA camera has been carefully characterized, and meet its spectral and radiometric requirements.

Harten, Gerard Van↗

Geometric calibration of the Multi-Angle Imager for Aerosols (MAIA)

The Multi-Angle Imager for Aerosols (MAIA) instrument is currently scheduled for launch into polar Earth orbitin 2022. MAIA uses a single camera on a 2-axis gimbal for multi-angle viewing. The camera focal plane consistsof one visible and one SWIR detector, comprising a total of 14 wavelength channels from the UV to SWIR.Three of the channels are polarimetric to enhance the camera's sensitivity to airborne particle type. The MAIAtelescope is a standard four-mirror anastigmat and has signi?cant distortion of the ?eld-of-view. Each channelin the camera comprises one or two rows of pixels, and each row has a total of 1216 pixels. This talk will reviewthe tests undertaken to measure pixel positions in the focal plane with respect to their corresponding angles inobject space, i.e. the pointing angle of each pixel. This measurement is necessary to achieve good geo-locationof ground control points, a precursor to the successful registration of the 14 channels to each other.

Bruegge, Carol J.↗

Regional Changes in Earths Color and Texture as Observed From Space Over a 15-Year Period

Earth-observing satellites provide global observations of many geophysical variables. As these variables are derived from measured radiances, the underlying radiance data are the most reliable sources of information for change detection. Here, we identify statistically significant trends in the color and spatial texture of the Earth as viewed from multiple directions from the Multi-angle Imaging SpectroRadiometer (MISR), which has been sampling the angular distribution of scattered sunlight since 2000. Globally, our results show that the Earth has been appearing relatively bluer (up to 1.6 % per decade from both nadir and oblique views) and smoother (up to 1.5 % per decade only from oblique views) over the past 15 years. The magnitude of the global blueing trends is comparable to that of uncertainties in radiometric calibration stability. Regional shifts in color and texture, which are significantly larger than global means, are observed, particularly over polar regions, along the boundaries of the subtropical highs, the tropical western Pacific, Southwestern Asia, and Australia. We demonstrate that the large regional trends cannot be explained either by uncertainties in radiometric calibration or variability in total or spectral solar irradiance; hence, they reflect changes internal to the Earths climate system. The 15-year-mean true color composites and texture images of the Earth at both nadir and oblique views are also presented for the first time.

regional trends↗

Ten Years of MISR Observations from Terra: Looking Back, Ahead, and in Between

The Multi-angle Imaging SpectroRadiometer (MISR) instrument has been collecting global Earth data from NASA's Terra satellite since February 2000. With its nine along-track view angles, four visible/near-infrared spectral bands, intrinsic spatial resolution of 275 m, and stable radiometric and geometric calibration, no instrument that combines MISR's attributes has previously flown in space. The more than 10-year (and counting) MISR data record provides unprecedented opportunities for characterizing long-term trends in aerosol, cloud, and surface properties, and includes 3-D textural information conventionally thought to be accessible only to active sensors.

remote sensing↗

Desert Test Site Uniformity Analysis

Desert test sites such as Railroad Valley (RRV) Nevada, Egypt-1, and Libya-4 are commonly targeted to assess the on-orbit radiometric performance of sensors. Railroad Valley is used for vicarious calibration experiments, where a field-team makes ground measurements to produce accurate estimates of top-of-atmosphere (TOA) radiances. The Sahara desert test sites are not instrumented, but provide a stable target that can be used for sensor cross-comparisons, or for stability monitoring of a single sensor. These sites are of interest to NASA's Atmospheric Carbon Observation from Space (ACOS) and JAXA's Greenhouse Gas Observation SATellite (GOSAT) programs. This study assesses the utility of these three test sites to the ACOS and GOSAT calibration teams. To simulate errors in sensor-measured radiance with pointing errors, simulated data have been created using MODIS Aqua data. MODIS data are further utilized to validate the campaign data acquired from June 22 through July 5, 2009. The first GOSAT vicarious calibration experiment was conducted during this timeframe.

Vicarious calibration↗

Calibration Refinements in Support of MISR

The Multi-angle Imaging SpectroRadiometer (MISR) is one of five instruments on-board the EOSI Terra spacecraft, and has collected science data since March 2000. A multi-angle capability is provided by ninecameras, which view up to 70' forward and aft of the spacecraft track and enable unique geophysical retrievals. Throughout its mission, a calibration team has made periodic refinements to the process used to calibrate MISR. These have resulted in improved absolute, and band and camera-relative calibrations, as well as in derived geophysical data products. Data reprocessing is on-going, such that these refinements also improve previous data acquisitions. The calibration process is believed to be mature at this time, with no other changes anticipated. Bimonthly deployments of the on-board-calibrator continue to monitor instrument response degradations, and provide correction coefficients needed to maintain the accuracy of the radiance products.

refinements↗

Comparison of Coincident Multiangle Imaging Spectroradiometer and Moderate Resolution Imaging Spectroradiometer Aerosol Optical Depths over Land and Ocean Scenes Containing Aerosol Robotic Network Sites

The Multiangle Imaging Spectroradiometer (MISR) and the Moderate Resolution Imaging Spectroradiometer (MODIS), launched on 18 December 1999 aboard the Terra spacecraft, are making global observations of top-of-atmosphere (TOA) radiances. Aerosol optical depths and particle properties are independently retrieved from these radiances using methodologies and algorithms that make use of the instruments corresponding designs. This paper compares instantaneous optical depths retrieved from simultaneous and collocated radiances measured by the two instruments at locations containing sites within the Aerosol Robotic Network (AERONET). A set of 318 MISR and MODIS images, obtained during the months of March, June, and September 2002 at 62 AERONET sites, were used in this study. The results show that over land, MODIS aerosol optical depths at 470 and 660 nm are larger than those retrieved from MISR by about 35% and 10% on average, respectively, when all land surface types are included in the regression. The differences decrease when coastal and desert areas are excluded. For optical depths retrieved over ocean, MISR is on average about 0.1 and 0.05 higher than MODIS in the 470 and 660 nm bands, respectively. Part of this difference is due to radiometric calibration and is reduced to about 0.01 and 0.03 when recently derived band-to-band adjustments in the MISR radiometry are incorporated. Comparisons with AERONET data show similar patterns.

Moderate Resolution Imaging Spectroradiometer (MOD↗

2003 Railroad Valley vicarious calibration experiment

The Multi-angle Imaging SpectroRadiometer (MISR) is one of five instruments on-board the EOS/Terra spacecraft. The instrument has nine cameras, which view up to 70 degrees forward and aft of the spacecraft track.

MISR↗

Instrument Verification Tests on the Multi-Angle Imaging SpectroRadiometer (MISR)

The Multi-angle Imaging SpectroRadiometer (MISR) cameras completed detailed calibrationa done characterization testing a year ago, as reported in earlier literature. Since that time the cameras have been assembled onto a common flight optical bench, along with photodiode detector standards and diffuse calibration targets.

MISR↗

On-Board Calibrator for the Multi-angle Imaging SpectroRadiometer

The EOS/MISR instrument includes nine pushroom cameras, each at different view to Earth, and an on-board calibrator. The latter includes photodiode detectors, used as the radiometric standards for the experiment, and two Spectralon diffuse panels.

Multi-angle Imaging SpectroRadiometer pushroom cam↗

The MISR Calibration Program

The Multiangle Imaging SpectroRadiometer (MISR) is currently under development for NASA's Earth Observing System. The instrument consists of nine pushbroom cameras, each with four spectral bands in the visible and near-infrared. The cameras point in different view directions to provide measurements from nadir to highly oblique view angles in the along-track plane. Multiple view-angle observations provide a unique resource for studies of clouds, aerosols, and the surface. MISR is built to challenging radiometric and geometric performance specifications. Radiometric accuracy, for example, must be within +/- 3%/ 1 sigma, and polarization insensitivity must be better than +/- 1 %. An onboard calibrator (OBC) provides monthly updates to the instrument gain coefficients. Spectralon diffuse panels are used within the OBC to provide a uniform target for the cameras to view. The absolute radiometric scale is established both preflight and in orbit through the use of detector standards. During the mission, ground data processing to accomplish radiometric calibration, geometric rectification and registration of the nine view-angle imagery, and geophysical retrievals will proceed in an automated fashion. A global dataset is produced every 9 days. This paper details the preflight characterization of the MISR instrument, the design of the OBC, and the radiance product processing.

Bruegge, Carol J.↗

State of The Art Radiometer Standards For NASA'S Earth Observing System

The Multi-Angle Imaging SpectroRadiometer (MISR), to be launched in 1998, is one of five instruments on NASA's first Earth Observing System (EOS) platform. The 3% absolute radiometric calibration requirement is considered challenging, particularly since it must be maintained through the five-year mission life. The Instrument requirements have led to the development of an On-Board Calibrator (OBC) consisting of diffuse panels and photodiode-based radiometric standards.

SpectroRadiometer↗

Comparison Of Measurments Of Atmospheric Water Vapor

Report presents experimental intercomparison among measurements by four spectrometric instruments for determining concentration of atmospheric water vapor. Three instruments ground-based and needed to provide independent data to calibrate and validate measurements taken by fourth instrument, which is airborne visible/infrared imaging spectrometer (AVIRIS). Remote down-looking instruments like AVIRIS increases accuracy and coverage of water-vapor measurements.

Bruegge, Carol J.↗