Engineering Papers⌕ Search

Engineering topics

Brown, Richard

Publications and source records attributed to Brown, Richard.

At least 37 records · Page 2

Resilient buildings for fire-adapted landscapes: EE and flexible loads integrated with solar and storage microgrids

Energy efficiency (EE) and flexible loads can be part of a resilient buildings packagewhen they are combined with solar and storage in a clean energy microgrid to reduce the carbonfootprint of buildings and enable resilience to extreme events. Recent large wildfires and an emerging understanding of the fire-adapted landscapes in the American West underscore the urgency of work towards scaling and commercializing these systems. For example, a recent power shutoff in Northern California (October 9-12, 2019) resulted in 738k customers disconnected at the peak of the outage and is emblematic of challenges to come. Our paper reports on insights from a clean energy microgrid deployment pilot that integrates a 50 kWAC PV array, a 109 kW / 174 kWh battery system, switchgear to safely isolate from the regional power system, and communicating controllers for HVAC and refrigeration. The project will be commissioned in May 2020 and is sited at a critical infrastructure site in rural Northern California – in this case a gasoline station with convenience store. Our experience and results shed light on capabilities of integrated microgrids to provide value to customers during blue sky conditions and resilience during black sky days with high fire risk, and what opportunities and barriers exist for scaling these integrated microgrid systems in the near term. We use a simulation model to estimate how EE and flexibility can extend the run time of solar and storage, improving the reliability of power at critical sites.

Alstone, Peter↗

Direct-DC Power in Buildings: Identifying the Best Applications Today for Tomorrow’s Building Sector

Driven by the increased use of direct current (DC) sources (photovoltaics, battery storage) and DC end-use devices (electronics, solid-state lighting, efficient motors), DC power distribution in buildings and DC microgrids have been proposed as a way to achieve greater efficiency, cost savings, and resiliency in a transitioning building sector. Despite these important benefits, several market and technological barriers inhibit the development of DC distribution, and the market for DC in buildings is still largely in the demonstration phase. Therefore, to jumpstart this technology, a clear path forward must emerge at this early stage of deployment. The goal of this paper is to define specific end-use cases for which DC distribution in buildings is a value proposition today by defining clear efficiency and resiliency benefits while addressing barriers to implementation. The paper begins with a technology and market assessment of DC distribution equipment, end uses, and technology standards. That is followed by results from an expert elicitation of DC power and building end-use professionals (e.g., electrical designers, building operators, engineers) and reports on-site visits and lessons learned from successful (and less successful) field deployments of DC distribution projects in North America. We present specific adoption pathways at the community and building level that can be implemented today, and evaluate them using qualitative and quantitative metrics, such as technology and market readiness, energy savings, and resiliency.

building-level electrical distribution↗

Solar+ Optimizer: A Model Predictive Control Optimization Platform for Grid Responsive Building Microgrids

With the falling costs of solar arrays and battery storage and reduced reliability of the grid due to natural disasters, small-scale local generation and storage resources are beginning to proliferate. However, very few software options exist for integrated control of building loads, batteries and other distributed energy resources. The available software solutions on the market can force customers to adopt one particular ecosystem of products, thus limiting consumer choice, and are often incapable of operating independently of the grid during blackouts. In this paper, we present the “Solar+ Optimizer” (SPO), a control platform that provides demand flexibility, resiliency and reduced utility bills, built using open-source software. SPO employs Model Predictive Control (MPC) to produce real time optimal control strategies for the building loads and the distributed energy resources on site. SPO is designed to be vendor-agnostic, protocol-independent and resilient to loss of wide-area network connectivity. The software was evaluated in a real convenience store in northern California with on-site solar generation, battery storage and control of HVAC and commercial refrigeration loads. Preliminary tests showed price responsiveness of the building and cost savings of more than 10% in energy costs alone.

14 SOLAR ENERGY↗

Developing Flexible, Networked Lighting Control Systems That Reliably Save Energy in California Buildings

An important strategy to meet California's ambitious energy efficiency goals is to use innovative wireless communications, embedded sensors, data analytics and controls to significantly reduce lighting energy use in commercial buildings. This project developed a suite of networked lighting solutions to further this goal. The technologies include a platform for low-cost sensing, distributed intelligence and communications, the “PermaMote,” which is a self-powered sensor and controller for lighting applications. The project team also developed a task ambient daylighting system that integrates sensors with data-driven daylighting control using an open communication interface, called the “Readings-At-Desk” (RAD) system. To address the problem of building occupants being confused about how to operate traditional lighting control systems, the research team created content that could be the basis for a user interface standard for lighting controls. Finally, to address the difficulty of ensuring that advanced lighting control systems actually deliver their promised energy savings, the project team developed a new method for evaluating and specifying lighting systems’ performance. The research team validated these technologies in the laboratory, showing significant lighting energy savings, up to 73% for the PermaMote sensor system from occupancy control and daylight dimming features, compared to the same light source (LED replacement lamps) operated via simple on/off scheduling. The project team also developed a proposed standard lighting data model and user interface elements, which were contributed to the ANSI Lighting Systems Committee (C137) for standardization. Existing data models are incomplete and inconsistent, whereas the lighting-specific data model developed here is clear and comprehensive, to serve as a starting point for creating common, universally agreed upon semantic definitions of key lighting parameters, to promote interoperability. For the task on verifiable performance of lighting systems, the project team developed a more effective metric for capturing the actual energy impact of a lighting system over time — the energy usage intensity (kWh/ft2/year). Three commercial lighting systems were tested in FLEXLAB® using this new metric, and the tests show a wide range in the accuracy of the self-reported energy-use metric, from 0.5% to 28% error compared to direct measurement of lighting energy using dedicated submeters. Overall, the project team estimates that these advanced technologies can reduce California office lighting energy use by 20% (above and beyond normal advanced lighting controls mandated by Title 24), resulting in about 1,600 GWh/year in savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy-saving opportunities of direct-DC loads in buildings

Despite the recent interest in direct current (DC) power distribution in buildings, the market for DC-ready loads remains small. The existing DC loads in various products or research test beds are not always designed to efficiently leverage the benefits of DC. This work addresses a pressing need for a study into the development of efficient DC loads. In particular, it focuses on documenting and demonstrating how to best leverage a DC input to eliminate or improve conversion stages in a load's power converter. This work identifies how typical building loads can benefit from DC input, including bath fans, refrigerators, wall adapters, task lights, and zone lighting. It then details the development of several prototypes that demonstrate efficiency savings with DC. The most efficient direct-DC loads are explicitly designed for DC from the ground up, rather than from an AC modification.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Accelerating the Deployment of Advanced Energy Communities: The Oakland EcoBlock A Zero Net Energy, Low Water Use Retrofit Neighborhood Demonstration Project

This report describes the design development process and recommendations of a Community-Scale Zero Net Energy Master Plan for a residential block in Oakland, the Oakland EcoBlock. The recommended master plan includes an integrated system of energy efficiency retrofits, a direct current solar/storage/electric vehicle microgrid, alternating/direct current houses, and water efficiency retrofits with rainwater capture. The recommended master plan is projected to be close to zero-net energy (95 percent) for homes, reduce carbon emissions by 65 percent at the block scale (including transportation), and reduce water use 60–70 percent. The integrated system of energy efficiency and a direct current solar/storage/electric vehicle (EV) charging microgrid is the first of its kind at the residential block scale. This breakthrough because the deep energy efficiency retrofit savings free up enough capacity in the solar supply and storage to enable residents to switch from natural gas to electricity for heating and domestic hot water and to provide EV charging for 33 percent of vehicle miles traveled. The savings in household transportation costs are a game changer because when combined with savings in the electric and water utility bills, the total cash flow savings are projected to fund the capital improvements of the proposed systems. This project’s benefits include lower and more predictable utility bills; greater resiliency because the system can operate during outages, and vastly improved indoor air quality by reducing natural gas consumption. The local energy storage reduces peak demand for the utility. California benefits from a model that exceeds the targets for reductions in energy consumption and carbon emissions and the reductions in water use address California’s severe water challenges. The Oakland EcoBlock is a transformative model for accelerating the rapid deployment of advanced energy communities.

decarbonization codes↗

Techno-economic analysis of DC power distribution in commercial buildings

Improvements in building end-use efficiency have significantly reduced the energy intensity of new buildings, but diminishing returns make it a challenge to build very-low energy buildings cost-effectively. A largely untapped efficiency strategy is to improve the efficiency of power distribution within buildings. Direct current (DC) distribution with modern power electronics has the potential to eliminate much of the power conversion loss in alternating current (AC) building distribution networks that include photovoltaics and DC end uses. Previous literature suggests up to 15% energy savings from DC power distribution in very energy efficient buildings with onsite generation and battery storage. This paper extends prior energy modeling of DC versus AC distribution in buildings, to consider the cost of implementing DC systems on a life-cycle basis. A techno-economic analysis framework based on commercially available products that evaluates the cost-effectiveness of DC systems is presented. The analysis is conducted for three commercial building types in two California climate zones and for various PV and battery storage capacities. Monte Carlo simulation is used to compute the payback period and lifecycle cost savings of DC versus AC distribution systems. A future-market scenario is also examined, which evaluates how future efficiency improvements in power converters and changes in electricity tariffs may affect cost savings. This analysis shows that DC systems can be cost-effective in all scenarios that include large capacities of battery storage and onsite solar, whereas for systems without storage, DC distribution is generally not cost-effective.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Exploration of PG&E Auto DR Incentive Options (Final Project Report)

Demand Response programs offer incentives to customers to modify energy use during times of peak demand. There is a growing trend toward automating demand response. The market benefits from the use of common communication standards to facilitate automation because it allows communication and control companies to build technology using common protocols that reduces the cost of integrating ADR technologies into buildings. Common communication standards also allow electricity providers to build common platforms to communicate with customer or aggregator end-use equipment. This report considers strategies for increasing the use of automated DR technology for residential and small and medium business (SMB) customers within the Pacific Gas and Electric (PG&E) service territory. PG&E is interested in designing new incentive structures for automated DR equipment. In developing these new structures, it is important to understand the incremental cost of the automated demand response (ADR) communication technology. This technology is usually imbedded in end-use controls to communicate with an end-use device. Standards based ADR technologies require that the control system have the ability to communicate using an open standard communication protocol, usually either Open Automated Demand Response (OpenADR, certification for which is available through the OpenADR Alliance) or Smart Energy Profile.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A simulation-based efficiency comparison of AC and DC power distribution networks in commercial buildings

Direct current (DC) power distribution has recently gained traction in buildings research due to the proliferation of on-site electricity generation and battery storage, and an increasing prevalence of internal DC loads. The research discussed in this paper uses Modelica-based simulation to compare the efficiency of DC building power distribution with an equivalent alternating current (AC) distribution. The buildings are all modeled with solar generation, battery storage, and loads that are representative of the most efficient building technology. A variety of paramet ric simulations determine how and when DC distribution proves advantageous. These simulations also validate previous studies that use simpler approaches and arithmetic efficiency models. This work shows that using DC distribution can be considerably more efficient: a medium sized office building using DC distribution has an expected baseline of 12% savings, but may also save up to 18%. In these results, the baseline simulation parameters are for a zero net energy (ZNE) building that can island as a microgrid. DC is most advantageous in buildings with large solar capacity, large battery capacity, and high voltage distribution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

United States Data Center Energy Usage Report

This report estimates historical data center electricity consumption back to 2000, relying on previous studies and historical shipment data, and forecasts consumption out to 2020 based on new trends and the most recent data available. Figure ES-1 provides an estimate of total U.S. data center electricity use (servers, storage, network equipment, and infrastructure) from 2000-2020. In 2014, data centers in the U.S. consumed an estimated 70 billion kWh, representing about 1.8% of total U.S. electricity consumption. Current study results show data center electricity consumption increased by about 4% from 2010-2014, a large shift from the 24% percent increase estimated from 2005-2010 and the nearly 90% increase estimated from 2000-2005. Energy use is expected to continue slightly increasing in the near future, increasing 4% from 2014-2020, the same rate as the past five years. Based on current trend estimates, U.S. data centers are projected to consume approximately 73 billion kWh in 2020.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

How low can they go when going with the flow? Tolerance of egg and larval fishes to rapid decompression

Egg and larval fish that drift downstream are likely to encounter river infrastructure and consequently rapid decompression, which may result in significant injury. In juvenile fish, pressure-related injury (or barotrauma) occurs when pressures fall sufficiently below the pressure at which the fish has acclimated. Because eggs and larvae are less-developed and more fragile than juveniles, there is a presumption that they may be at least as, if not more, susceptible to barotrauma injury, but studies to date report inconsistent results and none have considered the relationship between pressure change and barotrauma over a sufficiently broad range of pressure changes to enable detrimental levels to be properly determined. To address this, we exposed eggs and larvae of three physoclistic species to rapid decompression in a barometric chamber over a broad range of discrete pressure changes. Eggs, but not larvae, were unaffected by all levels of decompression tested. At exposure pressures below ~40 kPa, or ~40% of atmospheric pressure, swim bladder deflation occurred in all species and internal haemorrhage was observed in one species. None of these injuries killed the fish within 24 hours, but subsequent mortality cannot be excluded. Consequently, if larval drift is expected, it seems prudent to maintain exposure pressures at river infrastructure at 40% or more of the pressure to which a drifting larvae has acclimated.

break-point analysis↗

Using Public Participation to Improve MELs Energy Data Collection

Miscellaneous and electronic loads (MELs) comprise an increasing share of building energy consumption. Large-scale data collection is needed to inform meaningful energy reduction strategies because of the diversity of MELs and our lack of understanding about how people use them. Traditional methods of data collection, however, usually incur high labor and metering equipment expenses. As an alternative, this paper investigates the feasibility of crowdsourcing data collection to satisfy at least part of the data collection needs with acceptable accuracy. We assessed the reliability and accuracy of crowd-sourced data by recruiting 18 volunteers and testing our crowdsourcing protocol. The protocol asked volunteers to perform measurement tasks for three MELs devices of increasing complexity 1) record power meter and MELs product characteristics, 2) identify and measure all power modes available, and 3) report the measured power. Volunteers performed reasonably well for devices with functionalities with which they were familiar, but many could not correctly identify all available power modes in complex devices. Accuracy may improve when participants measure the power used by familiar devices in their home, or by providing more specific instructions, e.g. videos. Furthermore, crowdsourcing data collection from individual homeowners has the potential to generate valuable information about MELs energy use in homes when integrated with existing programs such as Home Energy Saver and Building America.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficiency in Small Server Rooms: Field Surveys and Findings

Fifty-seven percent of US servers are housed in server closets, server rooms, and localized data centers, in what are commonly referred to as small server rooms, which comprise 99percent of all server spaces in the US. While many mid-tier and enterprise-class data centers are owned by large corporations that consider energy efficiency a goal to minimize business operating costs, small server rooms typically are not similarly motivated. They are characterized by decentralized ownership and management and come in many configurations, which creates a unique set of efficiency challenges. To develop energy efficiency strategies for these spaces, we surveyed 30 small server rooms across eight institutions, and selected four of them for detailed assessments. The four rooms had Power Usage Effectiveness (PUE) values ranging from 1.5 to 2.1. Energy saving opportunities ranged from no- to low-cost measures such as raising cooling set points and better airflow management, to more involved but cost-effective measures including server consolidation and virtualization, and dedicated cooling with economizers. We found that inefficiencies mainly resulted from organizational rather than technical issues. Because of the inherent space and resource limitations, the most effective measure is to operate servers through energy-efficient cloud-based services or well-managed larger data centers, rather than server rooms. Backup power requirement, and IT and cooling efficiency should be evaluated to minimize energy waste in the server space. Utility programs are instrumental in raising awareness and spreading technical knowledge on server operation, and the implementation of energy efficiency measures in small server rooms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automated Measurement and Signaling Systems for the Transactional Network

The Transactional Network Project is a multi-lab activity funded by the US Department of Energy's Building Technologies Office. The project team included staff from Lawrence Berkeley National Laboratory, Pacific Northwest National Laboratory and Oak Ridge National Laboratory. The team designed, prototyped and tested a transactional network (TN) platform to support energy, operational and financial transactions between any networked entities (equipment, organizations, buildings, grid, etc.). PNNL was responsible for the development of the TN platform, with agents for this platform developed by each of the three labs. LBNL contributed applications to measure the whole-building electric load response to various changes in building operations, particularly energy efficiency improvements and demand response events. We also provide a demand response signaling agent and an agent for cost savings analysis. LBNL and PNNL demonstrated actual transactions between packaged rooftop units and the electric grid using the platform and selected agents. This document describes the agents and applications developed by the LBNL team, and associated tests of the applications.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy Efficient Digital Networks

Digital networks are the foundation of the information services, and play an expanding and indispensable role in our lives, via the Internet, email, mobile phones, etc. However, these networks consume energy, both through the direct energy use of the network interfaces and equipment that comprise the network, and in the effect they have on the operating patterns of devices connected to the network. The purpose of this research was to investigate a variety of technology and policy issues related to the energy use caused by digital networks, and to further develop several energy-efficiency technologies targeted at networks.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗