Development and potential of composite moderators for elevated temperature nuclear applications
Not Available
Engineering topics
Publications and source records attributed to Brown, Nick.
Not Available
A novel experiment to simulate cyclic dryout in boiling water reactors has been developed to better understand the performance of nuclear grade FeCrAl cladding in a BWR during dryout conditions caused by an Anticipated Operational Occurrence or Anticipated Transient Without SCRAM - both of which are Design Basis Accidents. Internally pressurized C26 M FeCrAl alloy cladding and Zircaloy-2 cladding were subjected to rapid 300°-650 °C thermal cycling in a steam environment; actual maximum temperatures were found to vary between materials but were always above 650 °C. In the range of 32–55 MPa hoop stress, Zircaloy-2 cladding burst within 1–16 cycles (about 100 s of dryout duration above 600 °C), while at 76 MPa hoop stress, C26 M cladding remained virtually undeformed after completing 54 cycles (over 1000 s of dryout duration above 600 °C). Higher temperature 300°-700 °C and 300°C–800 °C cycling experiments had to be performed to induce C26 M burst – failure occurred after 20 cycles in the former and during the first cycle in the latter. Zircaloy-2 and C26 M failure criteria were used to generate hoop stress specific dryout lifetimes. Overall, the simulated cyclic dryout experiments show that nuclear grade C26 M cladding has significantly enhanced survivability under dryout conditions relative to Zircaloy-2.
Nuclear fuel and cladding in a light water reactor must maintain integrity under all normal operational and anticipated operational occurrences. In a Boiling Water Reactor (BWR) some Anticipated Operational Occurrences (AOOs) and Anticipated Transients Without SCRAM (ATWS) events have been known to result in cladding damage due to dryout with conventional Zircaloy-2 claddings. This work presents an assessment of commercially-fabricated, accident tolerant iron-chromium-aluminum (FeCrAl) alloy C26M cladding in such events with regard to the ballooning failure mode for unirradiated cladding In the severe accident test station (SATS), an experiment has been developed to gauge accident tolerance of fuel cladding materials under simulated cyclic dryout conditions. Thermal cycling from 300°C to 650°C was implemented on C26M and Zircaloy-2 tubes. The C26M tube did not fail after 54 cycles. The Zircaloy- 2 tube run under the same parameters as the C26M tube failed during the fourth cycle, consistent with expectations from the literature. Due to thermal gradients present in the furnace, both tubes experienced a maximum temperature at ~780°C. Due to differences in tube geometry, the hoop stress of the C26M tube was significantly higher than that of the Zircaloy-2 tube, 76 MPa at the maximum peak temperature compared to 55 MPa at burst, respectively. The cyclic dryout experiments show an increased performance of C26M over Zircaloy-2 under simulated conditions, an indication of C26M possessing superior high temperature oxidation resistance, mechanical properties and potentially resistance to fatigue.