Engineering Papers⌕ Search

Engineering topics

Brooks, Thomas E.

Publications and source records attributed to Brooks, Thomas E..

Predictive Thermal Control (PTC) Technology to Enable Thermally Stable Telescopes: First Two Year Status

Predictive Thermal Control Technology (PTCT) development project is a multiyear effort initiated in Fiscal Year (FY) 2017, to mature the Technology Readiness Level (TRL) of critical technologies required to enable ultra-thermally-stable ultraviolet/optical/infrared (UVOIR) space telescope primary-mirror assemblies for ultra-high-contrast observations of exoplanets. Key accomplishments of 2017 to 2019 include: creating a high-fidelity STOP (Structural, Thermal, and Optical Performance) model of the AMTD-2 (Advance Mirror Technology Development) 1.5-meter Ultra-Low Expansion (ULE®) mirror (manufactured by Harris Corp) by merging 3D X-Ray computed tomography data of the ‘as-built’ mirror and coefficient of thermal expansion (CTE) data maps for each of the 18 core elements; partially validating this model by measuring the mirror’s response to bulk temperature changes and lateral thermal gradients; designed and built (with PTC partner Harris Corp) a 1.5-meter enclosure with 26 actively-control thermal zones; and defined specifications for a potential 4-meter primary mirror thermal enclosure for the Habitable Exoplanet (HabEx) Imager mission.

Astrophysics↗

Optothermal Stability of Large ULE and Zerodur Mirrors

Marshall Space Flight Center's (MSFC) X-ray and Cryogenic Test Facility (XRCF) has tested the optothermal stability of two low-CTE, large-aperture mirrors in a thermal vacuum chamber. The mirrors deformed from several causes such as: thermal gradients, thermal soaks, coefficient of thermal expansion (CTE) gradients, CTE mismatch, and stiction. This paper focuses on how the aforementioned conditions affected the surface figure of the large optics while in vacuum at temperatures ranging from 230 to 310 K (-43 to 37 ˚C). The presented data, conclusions, and taxonomy are useful for designing mirrors and support structures for telescopes. The data is particularly useful for telescopes that require extreme dimensional stability or telescopes that operate at a temperature far from ambient.

Brooks, Thomas E.↗

Predictive Thermal Control Applied to HabEx

Exoplanet science can be accomplished with a telescope that has an internal coronagraph or with an external starshade. An internal coronagraph architecture requires extreme wavefront stability (10 pm change/10 minutes for 10(exp -10) contrast), so every source of wavefront error (WFE) must be controlled. Analysis has been done to estimate the thermal stability required to meet the wavefront stability requirement. This paper illustrates the potential of a new thermal control method called predictive thermal control (PTC) to achieve the required thermal stability. A simple development test using PTC indicates that PTC may meet the thermal stability requirements. Further testing of the PTC method in flight-like environments will be conducted in the X-ray and Cryogenic Facility (XRCF) at Marshall Space Flight Center (MSFC).

Brooks, Thomas E.↗

Modeling the Extremely Lightweight Zerodur Mirror (ELZM) Thermal Soak Test

Exoplanet science requires extreme wavefront stability (10 pm change/10 minutes), so every source of wavefront error (WFE) must be characterized in detail. This work illustrates the testing and characterization process that will be used to determine how much surface figure error (SFE) is produced by mirror substrate materials' CTE distributions. Schott's extremely lightweight Zerodur mirror (ELZM) was polished to a sphere, mounted, and tested at Marshall Space Flight Center (MSFC) in the X-Ray and Cryogenic Test Facility (XRCF). The test transitioned the mirror's temperature from an isothermal state at 292K to isothermal states at 275K, 250K and 230K to isolate the effects of the mirror's CTE distribution. The SFE was measured interferometrically at each temperature state and finite element analysis (FEA) has been completed to assess the predictability of the change in the mirror's surface due to a change in the mirror's temperature. The coefficient of thermal expansion (CTE) distribution in the ELZM is unknown, so the analysis has been correlated to the test data. The correlation process requires finding the sensitivity of SFE to a given CTE distribution in the mirror. A novel hand calculation is proposed to use these sensitivities to estimate thermally induced SFE. The correlation process was successful and is documented in this paper. The CTE map that produces the measured SFE is in line with the measured data of typical boules of Schott's Zerodur glass.

Brooks, Thomas E.↗