At least 19 records

System, algorithm, and method using short pulse interrogation with neutrons to detect and identify matter

A system, method, and algorithm for detecting and identifying special nuclear material (SNM) (including fissionable material), explosives, or drugs is disclosed. This material detection system relies on active interrogation of material using a short, intense neutron pulse, and characterization of the resulting prompt gamma response in two short time windows, the first concurrent with and the second immediately following the end of the neutron pulse, optionally subject to a total transit delay time of the neutrons from the neutron source to the target and from the target to the gamma detector. A high data rate analysis system implements data stream analysis and statistical correlations of the two short time window gamma responses to rapidly detect or identify SNM, explosives, or drugs. The duration of the neutron pulse is so short that minimal dose results. Various shields help to minimize the background signal falling on the gamma detector to improve sensitivity.

Derzon, Mark S.↗

Remote vibration sensing through opaque media using permanent magnets

A method of sensing vibrations or displacements remotely is provided. Magnets are attached to vibrating objects or the vibrating objects themselves are magnetic. A number of magnetic sensors are placed a specified distance from the magnets. Vibrational displacement of the vibrating objects is determined according to a model that maps changes in magnetic field to vibrations or spatial displacements.

Mazumdar, Yi Chen↗

System and method for measuring fluid properties using magnetic field techniques via magnetic tracer

A method and apparatus for determining a property of a fluid in a vessel. The method uses magnetic tracer particles and an externally applied magnetic field which orients the particles. When the fluid moves, it changes the orientation of the tracer particles, thus changing the magnetic fields. These changes are detected by external magnetic field sensors. By using mathematical models, the property of the fluid in the vessel is determined from the detected magnetic field. In this manner, fluid vorticity, velocity, strain and stress may be estimated.

42 ENGINEERING↗

Wireless Temperature Sensing Using Permanent Magnets for Nonlinear Feedback Control of Exothermic Polymers

Epoxies and resins can require careful temperature sensing and control in order to monitor and prevent degradation. To sense the temperature inside a mold, it is desirable to utilize a small, wireless sensing element. In this paper, we describe a new architecture for wireless temperature sensing and closed-loop temperature control of exothermic polymers. This architecture is the first to utilize magnetic field estimates of the temperature of permanent magnets within a temperature feedback control loop. We further improve performance and applicability by demonstrating sensing performance at relevant temperatures, incorporating a cure estimator, and implementing a nonlinear temperature controller. This novel architecture enables unique experimental results featuring closed-loop control of an exothermic resin without any physical connection to the inside of the mold. In this paper we describe each of the unique features of this approach including magnetic field-based temperature sensing, Extended Kalman Filtering (EKF) for cure state estimation, and nonlinear feedback control over time-varying temperature trajectories. We use experimental results to demonstrate how low-cost permanent magnets can provide wireless temperature sensing up to ~90°C. In addition, we use a polymer curecontrol test-bed to illustrate how internal temperature sensing can provide improved temperature control over both short and long time-scales. In conclusion, this wireless temperature sensing and control architecture holds value for a range of manufacturing applications.

47 OTHER INSTRUMENTATION↗

Remote Distributed Vibration Sensing Through Opaque Media Using Permanent Magnets

Vibration sensing is critical for a variety of applications from structural fatigue monitoring to understanding the modes of airplane wings. In particular, remote sensing techniques are needed for measuring the vibrations of multiple points simultaneously, assessing vibrations inside opaque metal vessels, and sensing through smoke clouds and other optically challenging environments. Here, in this paper, we propose a method which measures high-frequency displacements remotely using changes in the magnetic field generated by permanent magnets. We leverage the unique nature of vibration tracking and use a calibrated local model technique developed specifically to improve the frequency-domain estimation accuracy. The results show that two-dimensional local models surpass the dipole model in tracking high-frequency motions. A theoretical basis for understanding the effects of electronic noise and error due to correlated variables is generated in order to predict the performance of experiments prior to implementation. Simultaneous measurements of up to three independent vibrating components are shown. The relative accuracy of the magnet-based displacement tracking with respect to the video tracking ranges from 40 to 190 μm when the maximum displacements approach ±5 mm and when sensor-to-magnet distances vary from 25 to 36 mm. Finally, vibration sensing inside an opaque metal vessel and mode shape changes due to damage on an aluminum beam are also studied using the wireless permanent-magnet vibration sensing scheme.

42 ENGINEERING↗

Magnetic Methods for Tracking Particle Motions and Temperatures within Opaque Vessels

A three year LDRD was undertaken to look at the feasibility of using magnetic sensing to determine flows within sealed vessels at high temperatures and pressures. Uniqueness proofs were developed for tracking of single magnetic particles with multiple sensors. Experiments were shown to be able to track up to 3 dipole particles undergoing rigid-body rotational motion. Temperature was wirelessly monitored using magnetic particles in static and predictable motions. Finally high-speed vibrational motion was tracked using magnetic particles. Ideas for future work include using small particles for measuring vorticity and better calibration methods for tracking multiple particles.

47 OTHER INSTRUMENTATION↗

Remote temperature distribution sensing using permanent magnets

Remote temperature sensing is essential for applications in enclosed vessels where feedthroughs or optical access points are not possible. A unique sensing method for measuring the temperature of multiple closely-spaced points is proposed using permanent magnets and several three-axis magnetic field sensors. The magnetic field theory for multiple magnets is discussed and a solution technique is presented. Experimental calibration procedures, solution inversion considerations and methods for optimizing the magnet orientations are described in order to obtain low-noise temperature estimates. The experimental setup and the properties of permanent magnets are shown. Finally, experiments were conducted to determine the temperature of nine magnets in different configurations over a temperature range of 5 to 60 degrees Celsius and for a sensor-to-magnet distance of up to 35 mm. Furthermore, to show the possible applications of this sensing system for measuring temperatures through metal walls, additional experiments were conducted inside an opaque 304 stainless steel cylinder.

47 OTHER INSTRUMENTATION↗

Rheological and Mechanical Property Measurements of PMDI Foam at Elevated Temperatures

A study was undertaken to determine the viscosity of liquefied 20 lb/ft 3 poly methylene diisocyanate (PMDI) foam and the stress required to puncture solid PMDI foam at elevated temperatures. For the rheological measurements the foam was a priori liquefied in a pressure vessel such that the volatiles were not lost in the liquefaction process. The viscosity of the liquefied PMDI foam was found to be Newtonian with a power law dependence on temperature log 10 (μ/Pa s) = 20.6 – 9.5 log 10 (T/°C) for temperatures below 170 °C. Above 170 °C, the viscosity was in the range of 0.3 Pa s which is close to the lower measurement limit (≈ 0.1 Pa s) of the pressurized rheometer. The mechanical pressure required to break through 20lb/ft 3 foam was 500-800 psi at temperatures from room temperature up to 180 °C. The mechanical pressure required to break through 10 lb/ft 3 was 170-300 psi at temperatures from room temperature up to 180 °C. We have not been able to cause gas to break through the 20 lb/ft 3 PMDI foam at gas pressures up to 100 psi.

36 MATERIALS SCIENCE↗

The importance of experimental design on measurement of dynamic interfacial tension and interfacial rheology in diffusion-limited surfactant systems

Pendant bubble and drop devices are invaluable tools in understanding surfactant behavior at fluid–fluid interfaces. The simple instrumentation and analysis are used widely to determine adsorption isotherms, transport parameters, and interfacial rheology. However, much of the analysis performed is developed for planar interfaces. Moreover, the application of a planar analysis to drops and bubbles (curved interfaces) can lead to erroneous and unphysical results. We revisit this analysis for a well-studied surfactant system at air–water interfaces over a wide range of curvatures as applied to both expansion/contraction experiments and interfacial elasticity measurements. The impact of curvature and transport on measured properties is quantified and compared to other scaling relationships in the literature. Our results provide tools to design interfacial experiments for accurate determination of isotherm, transport and elastic properties.

36 MATERIALS SCIENCE↗