Engineering Papers⌕ Search

Engineering topics

Bromage, J. (ORCID:000000030720093X)

Publications and source records attributed to Bromage, J. (ORCID:000000030720093X).

Degradation of temporal contrast from post-pedestal interference with a chirped pulse in an optical parametric amplifier

Pre-pedestal generation is observed in a 0.35-PW laser front end coming from a post-pedestal via instantaneous gain and pump depletion in an optical parametric amplifier during chirped-pulse amplification. Generalized simulations show how this effect arises from gain nonlinearity and applies to all optical parametric chirped-pulse–amplification systems with a post-pedestal. An experiment minimizing the effect of B -integral is used to isolate and study the newly observed conversion of a continuous post-pedestal into a continuous pre-pedestal. Matching numerical simulations confirm experimental results and additionally reveal how third-order dispersion largely controls the slope of the generated pre-pedestal.

47 OTHER INSTRUMENTATION↗

Final amplifier of an ultra-intense all-OPCPA system with 13-J output signal energy and 41% pump-to-signal conversion efficiency

Optical parametric chirped-pulse amplification (OPCPA) using high-energy Nd:glass lasers has the potential to produce ultra-intense pulses (>10 23 W/cm 2 ). We report on the performance of the final high-efficiency amplifier in an OPCPA system based on large-aperture (63 × 63-mm 2 ) partially deuterated potassium dihydrogen phosphate (DKDP) crystals. The seed beam (180-nm bandwidth, 110 mJ) was provided by the preceding OPCPA stages. A maximum pump-to-signal conversion efficiency of 41% and signal energy up to 13 J were achieved with a 52-mm-long DKDP crystal due to the flattop super-Gaussian pump beam profile and flat-in-time pulse shape.

47 OTHER INSTRUMENTATION↗

Achieving 100 GW idler pulses from an existing petawatt optical parametric chirped pulse amplifier

Optical parametric chirped-pulse-amplification produces two broadband pulses, a signal and an idler, that can both provide peak powers >100 GW. In most cases the signal is used, but compressing the longer-wavelength idler opens up opportunities for experiments where the driving laser wavelength is a key parameter. This paper will describe several subsystems that were added to a petawatt class, Multi-Terawatt optical parametric amplifier line (MTW-OPAL) at the Laboratory for Laser Energetics to address two long-standing issues introduced by the use of the idler, angular dispersion, and spectral phase reversal. To the best of our knowledge, this is the first time that compensation of angular dispersion and phase reversal has been achieved in a single system and results in a 100 GW, 120-fs duration, pulse at 1170 nm.

47 OTHER INSTRUMENTATION↗

High-resolution mapping of phase-matching conditions in second-order nonlinear crystals

We demonstrate the spatial mapping of phase-matching conditions in nonlinear crystals using detuned second-harmonic generation. A beam-stabilization system cancels out the angular wobbling of the translation stages that scan the crystal under test in front of the static probe beam at the fundamental frequency. A submillimeter resolution over the full scanned aperture, 50 × 50 mm 2 , is demonstrated. The mapping of several partially deuterated potassium dihydrogen phosphate (DKDP) crystals reveals the spatially nonuniform phase-matching conditions due to internal variations in crystal properties and high-frequency surface variations.

36 MATERIALS SCIENCE↗

Simultaneous contrast improvement and temporal compression using divided-pulse nonlinear compression

We experimentally demonstrate how divided-pulse nonlinear compression can be used to improve the temporal contrast of a laser pulse train while simultaneously temporally compressing the pulses. We measure a contrast improvement of almost four orders of magnitude on a nanosecond time scale and temporally compress the pulses from 1.2 ps to 187 fs. The efficiency of our method is also competitive with other contrast improvement methods, with 72% efficiency measured for the main pulse. We expect the method will be useful in the continuing development of high-power, Yb regenerative amplifiers, which suffer from both significant prepulses and relatively long pulse durations.

47 OTHER INSTRUMENTATION↗

Effect of the pump beam profile and wavefront on the amplified signal wavefront in optical parametric amplifiers

We present a theoretical and experimental analysis of the signal phase introduced by the pump-beam wavefront and spatial profile during optical parametric amplification (OPA) process. The theory predicts the appearance of an additional wavefront in the amplified signal beam that is proportional to the spatial derivative of the pump-beam wavefront. The effect of the pump-beam profile on the signal-beam wavefront is also investigated. Our experiments tested these theoretical predictions by comparing the wavefront of the signal beam before and after amplification in a multi-joule broadband OPA. The measured signal wavefront was shown to have the expected dependence on the pump-beam profile and wavefront. These results can be considered when designing petawatt-scale ultrabroadband optical parametric chirped-pulse–amplification systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗