Engineering PapersSearch

Engineering topics

Brewer, E. B.

Publications and source records attributed to Brewer, E. B..

Hypersonic rarefied wake characterization

Results of a numerical study using the direct simulation Monte Carlo (DSMC) method are presented for hypersonic rarefied flow over an aeroassisted space transfer vehicle (ASTV). The emphasis of the study is the characterization of the near wake region which includes the ASTV payload. The study covered the transitional flow regime from near continuum to free molecular. Calculations show that the character of the near wake is significantly affected by the presence of the payload. Flow separation occurs when an afterbody is present throughout the transitional flow regime. In contrast, when no afterbody is present, no separation is observed until the flow approaches continuum.

Brewer, E. B.

Results of aerothermodynamic heating tests on a 0.013-scale model solid rocket booster in the NASA/LaRC unitary plan wind tunnel (SH12F)

A 0.013 scale model of the solid rocket booster (SRB) used to launch the space shuttle was tested at a Mach number of 3.7 and Reynolds numbers of 1,500,000 and 3,500,000 per foot. The objective of the test was to obtain aerodynamic heat transfer data on the surface of scaled models of the SRB at simulated full scale reentry flight conditions. Three separate models were utilized to measure film coefficients over an angle of attack range from 0 deg to 180 deg at 0 deg sideslip. All three models were representations of the MCR0200 baseline configuration and varied only by the way they were mounted in the tunnel. Model A, sting mounted thru the model base, was utilized for testing between 0 deg and 40 deg angle of attack. Model B was blade mounted from the top of the model and was tested between 60 deg and 120 deg angle of attack. Model C was sting mounted thru the model nose and utilized for testing between 140 deg and 180 deg angle of attack.

Brewer, E. B.

Pressure and heat flux results from the space shuttle/external fuel tank interaction test at Mach numbers 16 and 19

Heat transfer rates and pressures were measured on a 0.0175-scale model of the space shuttle external tank (ET), model MCR0200. Tests were conducted with the ET model separately and while mated with a 0.0175-scale model of the orbiter, model 21-OT (Grumman). The tests were conducted in the AEDC-VKF Hypervelocity Wind Tunnel (F) at Mach numbers 16 and 19. The primary data consisted of the interaction heating rates experienced by the ET while mated with the orbiter in the flight configuration. Data were taken for a range of Reynolds numbers from 50,000 to 65,000 under laminar flow conditions.

Brewer, E. B.