Engineering PapersSearch

Engineering topics

Brennan, P. J.

Publications and source records attributed to Brennan, P. J..

Development of an Advanced Trapezoidal Axially Grooved (ATAG) heat pipe

This paper discusses the breadboard development of an Advanced Trapezoidal Axially Grooved (ATAG) heat pipe, which will satisfy space constructible radiator heat rejection requirements for large space power systems. The ATAG heat pipe development program includes a technology demonstration of Space Station heat load and temperature requirements through the design, fabrication, and testing of breadboard and preprototype units. A parametric analysis was conducted to determine trapezoidal groove geometries that could meet the transport performance goal and could be fabricated by available extrusion technology for a diameter chosen to be compatible with an existing development test unit of a cylindrical, pressure-actuated contact heat exchanger. Performance test results for the breadboard heat pipes are presented.

Richter, R. F. G.

HEPP - A low temperature Heat Pipe Experiment Package developed for flight on-board the Long Duration Exposure Facility /LDEF/

The Heat Pipe Experiment Package (HEPP) is designed to provide a flight evaluation system for low temperature heat pipes. The HEPP will be flown aboard the Long Duration Exposure Facility which will be launched and retrieved as part of the Space Shuttle program. The experiment contains two heat pipes: an axially grooved fixed conductance heat pipe and a liquid blockage thermal diode. A phase change material canister is also integrated with a radiant cooler system. Additional hardware consists of supporting electrical equipment, including electronics for signal conditioning and command functions, a data recorder, and a hermetically sealed battery which powers the experiment. A thermal model was developed to simulate the behavior of the HEPP and a ground test program was conducted to verify the predicted performance of the equipment.

Suelau, H. J.

Axially grooved heat pipes - 1976

This paper summarizes the 'state-of-the-art' of axially grooved heat pipes. Applications are identified and the related heat pipe design and performance are defined. Recent developments in the analysis, design and fabrication of axially grooved hardware are also discussed. A mathematical model which predicts the hydrodynamic behavior and accounts for liquid recession, liquid/vapor shear interaction and 1-g puddle flow is also presented. Performance data for various fluids in the 100-500 K range is compared to predictions from the Groove Analysis Program (GAP). Finally, a simplified closed form solution which accounts for gravity effects, self-priming and composite pumping by the grooves as well as all of the hydrodynamic losses is also discussed.

Brennan, P. J.

Development of a low temperature phase change material package

Test data obtained for a low temperature phase change material (PCM) canisters are presented. The canister was designed to provide up to 30 w-hrs of storage capacity at approximately -90 C with an overall thermal conductance which is greater than 8 w/deg C. N-heptane which is an n-paraffin and has a -90.6 C freezing point was used as the working fluid. The canister was fabricated from aluminum and has an aluminum honeycomb core. Its void volume permits service temperatures up to 70 C. Results obtained from component and system's tests indicate well defined melting and freezing points which are repeatable and within 1 C of each other. Subcooling effects are less than 0.5 C and are essentially negligible. Measured storage capacities are within 94 to 88% the theoretical.

Brennan, P. J.

Development and test of two flexible cryogenic heat pipes

Results are presented for a comprehensive test program directed toward determining the physical and thermal performance of two flexible cryogenic heat pipes that can provide a highly efficient thermal link between a detector and a space radiator or other cooling system in spacecraft applications. A 100-200 K high-power heat pipe is tested with methane at 100-140 K while a 15-100 K low-temperature pipe is designed for operation with nitrogen and oxygen and is optimized for oxygen in the range 75-90 K. Parametric performance and design tradeoff studies are carried out to determine the optimum geometry and materials for the container and wicking systems. A spiral multiwrap wick in conjunction with braided bellows appears to be a workable solution to the problem of developing highly flexible heat transport devices for cryogenic applications.

Wright, J. P.

Application of axial grooves to cryogenic variable conductance heat pipe technology

Tests results obtained with an ATS axial groove aluminum extrusion adapted for use as a cryogenic thermal diode and/or a variable conductance heat pipe are presented. Ethane at a nominal operating temperature of 185 C was used as working fluid. In addition to both active and passive gas control, diode designs utilizing gas blockage or liquid trap were investigated. Specific requirements and performance parameters such as transient behavior, reservoir sizes, shutdown energy, etc., were evaluated. Results are also presented for tests where the liquid trap was used as a secondary heat pipe to demonstrate thermal switching with simultaneous heat pipe operation and diode shutdown.

Brennan, P. J.

Long term performance of the advanced thermal control flight experiment

The Advanced Thermal Control Flight Experiment (ATFE) is providing the first zero-g flight data for the performance of a thermal diode heat pipe and an electrical Feedback Controlled Heat Pipe (FCHP). The temperature stability derived from the melting and freezing of octadecane is also being evaluated in this experiment. Flight data for the different operational modes are compared to ground test data, and the performance of the individual components is analyzed. Also, the ATFE's long term behavior from launch through September 30, 1975, is evaluated. The temperature control capability of a thermal diode, phase change material, and FCHP was demonstrated over more than 500 days of flight operation and each of these components should be considered in future applications. Both the diode and FCHP transport more than 20 W in the normal and passive modes during maximum conditions. Up to 30 W has been carried by the FCHP when the auxiliary heater is applied. The "OFF-conductance" of the diode has improved substantially in flight. A 1.4 W decrease in backflow has been realized by more complete blockage. The variable conductance behavior of the FCHP is essentially unchanged with time and relative to ground tests. Degradation of the radiator and reservoir surfaces have resulted in a partial loss of control by the FCHP during normal mode operation; however, manual control at an elevated set point has demonstrated the FCHP's ability to provide regulated temperature control to within + or - 2 C. The same pipe when operated as a passive VCHP controlled at 35 + or - 10 C with the same test conditions.

Brennan, P. J.

ATS-6 - Flight performance of the Advanced Thermal Control Flight Experiment

The Advanced Thermal Control Flight Experiment on ATS-6 was designed to demonstrate the thermal control capability of a thermal diode (one-way) heat pipe, a phase-change material for thermal storage, and a feedback-controlled heat pipe. Flight data for the different operational modes are compared to ground test data, and the performance of the components is evaluated on an individual basis and as an integrated temperature-control system.

Kirkpatrick, J. P.

Performance analysis of the advanced thermal control flight experiment

Flight data for the different operational modes of the advanced thermal control flight experiment are presented and compared with ground-test data. Performance of the system with feedback control is compared to performance without such control, and performances of the individual components are analyzed. Finally, changes in performance from launch through March 31, 1975, are discussed and analyzed. All thermal control components are performing as predicted for the existing flight environment. However, the daily reservoir and radiator temperatures during peak solar input are greater than those experienced in ground acceptance tests. These increased temperatures have resulted in a loss of control by the feedback-controlled variable-conductance heat pipe for several hours around the period of maximum insolation. The higher temperatures are apparently due to contamination and/or degradation of the second-surface mirrors which cover the reservoir and radiator.

Kirkpatrick, J. P.

Analysis of fourth sounding rocket heat pipe experiment, summary report

An analysis was made of the cryogenic axial groove methane and axial groove nitrogen heat pipes. Data cover the establishment of reliable start-up and operational data for the cryogenic pipe and its reference control pipes, and requirements for and the applicability of cryogenic heat pipes to NASA coolers.

Brennan, P. J.

ERTS-C (Landsat 3) cryogenic heat pipe experiment definition

A flight experiment designed to demonstrate current cryogenic heat pipe technology was defined and evaluated. The experiment package developed is specifically configured for flight aboard an ERTS type spacecraft. Two types of heat pipes were included as part of the experiment package: a transporter heat pipe and a thermal diode heat pipe. Each was tested in various operating modes. Performance data obtained from the experiment are applicable to the design of cryogenic systems for detector cooling, including applications where periodic high cooler temperatures are experienced as a result of cyclic energy inputs.

Brennan, P. J.

Parametric performance of extruded axial grooved heat pipes from 100 to 300 K

Extensive performance data derived from tests with an aluminum axial grooved extruded heat pipe is presented for oxygen, methane, ethane, and ammonia as working fluids. The effects of operating temperature, fluid inventory, heat flux, and elevation on the transport capability and the evaporator and condenser film coefficients are measured and compared to theory. The data correlation indicates that, in addition to the viscous pressure drop of the fluid, a vapor induced liquid pressure drop must be taken into account at temperatures near or below the normal boiling point of the fluid. Methane, ethane, and ammonia are all suitable working fluids for this groove geometry; however, oxygen, because of its low static height, is at best marginal in the 100-120 K range.

Schlitt, K. R.

Advanced Thermal Control Flight Experiment.

The advanced Thermal Control Flight Experiment on the Applications Technology Satellite (ATS-F) will evaluate, for the first time in a space environment, the performance of a feedback-controlled variable conductance heat pipe and a heat pipe thermal diode. In addition, the temperature control aspects of a phase-change material (PCM) will be demonstrated. The methanol/stainless steel feedback-controlled heat pipe uses helium control gas that is stored in a wicked reservoir. This reservoir is electrically heated through a solid state controller that senses the temperature of the heat source directly. The ammonia/stainless steel diode heat pipe uses excess liquid to block heat transfer in the reverse direction. The PCM is octadecane. Design tradeoffs, fabrication problems, and performance during qualification and flight acceptance tests are discussed.

Kirkpatrick, J. P.