Engineering Papers⌕ Search

Engineering topics

Bregman, J. D.

Publications and source records attributed to Bregman, J. D..

At least 37 records · Page 2

Infrared emission from comets

IR observations of seven comets from 4 to 20 microns are discussed. It is found that the IR emission depends primarily on the comet's heliocentric distance. A model is applied to the observations based on grain populations composed of a mixture of silicate and amorphous carbon particles in the mass ratio of about 40 to 1, with a power-law size distribution similar to that inferred for Comet Halley. The results suggest that the 3.4-micron feature observed in Comet Halley is primarily due to thermal emission from the comet dust when the comet is close to the sun. It is found that the emission curve from about 4 to 8 microns provides the best spectral region for estimating the cometary grain temperature distribution.

Krishna Swamy, K. S.↗

Infrared Emission from Comets

A brief discussion of the infrared observations from 4 to 20 micrometers of seven comets is presented. The observed infrared emission from comets depends primarily on their heliocentric distance. A model based on grain populations composed of a mixture of silicate and amorphous carbon particles in the mass ratio of about 40 to 1, with a power-law size distribution similar to that inferred for comet Halley, is applied to the observations. The model provides a good match to the observed heliocentric variation of both the 10 micrometers feature and the overall thermal emission from comets West and Halley. Matches to the observations of comet IRAS-Araki-Alcock and the antitail of comet Kohoutek require slightly larger grains. While the model does not match the exact profile and position of the 3.4 micrometers feature discovered in comet Halley, it does produce a qualitative fit to the observed variation of the feature's strength as a function of heliocentric distance. The calculations predict that the continuum under the 3.4 micrometers feature is due primarily to thermal emission from the comet dust when the comet is close to the Sun and to scattered solar radiation at large heliocentric distances, as is observed. A brief discussion of the determination of cometary grain temperatures from the observed infrared emission is presented. It is found that the observed shape of the emission curve from about 4 to 8 micrometers provides the best spectral region for estimating the cometary grain temperature distribution.

Swamy, K. S. Krishna↗

Spectral line profiles of nickel and argon in supernova 1987A - Expansion velocity and electron scattering effects

Spectra of SN 1987A showing the Ni II 6.634-micron and Ar II 6.983-micron fine-structure lines were obtained from the Kuiper Airborne Observatory in April 1988. The signal-to-noise ratio of 100 near the peaks and resolving power of 200 are sufficient to show the average velocity of expansion from the core of about 1400 km/s and to indicate the range of velocities. An asymmetry in the profiles of both lines and a redshift of the line centroids of about 440 km/s above the 280-km/s recessional velocity of the LMC can be explained in terms of scattering of the photons by electrons in the expanding hydrogen envelope of the supernova. A mass of 0.0030 solar masses of Ni II can be deduced from the line strength of the Ni II line and a mass of 0.0009 solar masses of Ar II from the Ar II line strength.

Witteborn, F. C.↗

Nickel, argon and cobalt in the infrared spectrum of SN1987A - The core becomes visible

Infrared spectra of supernova 1987A taken in April and November 1987 are presented, showing two distinctly different stages in the evolution of the expanding gas shell. The optical and infrared spectrum in April originated from the hydrogen envelope and show weak hydrogen lines rising above a 5,000-K photospheric continuum. The November spectrum was dominated by strong emission lines from heavy elements as well as many lines from highly excited levels of hydrogen, with peak flux levels in the lines at or slightly above the level of the continuum in April. It is concluded that the inner regions of the supernova were just becoming visible in early 1988. It is expected that these regions contain heavy elements produced by advanced nuclear burning stages in the progenitor star and in the shock wave that ejected all material external to the iron core.

Rank, D. M.↗

Airborne and groundbased spectrophotometry of comet P/Halley from 5-13 micrometers

Spectrophotometry of comet Halley from 5-13 microns was obtained from the Kuiper Airborne Observatory and from the Lick Observatory Nickel Telescope, revealing a strong broad emission band at 10 microns and a weak feature at 6.8 microns. The 10-micron band is identified with silicate materials, and the primary component of the silicate emission is suggested to be due to olivine. The 6.8 micron feature may be due either to carbonates or the C-H deformation mode in organic molecules. The data indicate that small particles are abundant in the coma and that the dust contains at least two physically separate components. Significant spatial and temporal variations are also noted in the spectrum.

Bregman, J. D.↗

Airborne spectrophotometry of Comet Halley from 5 to 9 microns

Spectrophotometry from 5 to 9 microns (resolution = 0.02) of comet Halley was obtained from the Kuiper Airborne Observatory on 1985 Dec. 12.1 and 1986 April 8.6 and 10.5 UT. Two spectral features are apparent in all the observations, one from 5.24 to 5.6 microns, and the silicate emission feature which has an onset between 7 and 8 microns. There is no evidence for the 7.5 microns feature observed by the Vega 1 spacecraft; the large difference between the areal coverage viewed from the spacecraft and the airplane may explain the discrepancy. Color temperatures significantly higher than a blackbody indicate that small particles are abundant in the coma. Significant spatial and temporal variations in the spectrum show trends similar to those observed from the ground.

Campins, H.↗

Infrared spectra of WC10 planetary nebulae nuclei

The 5.2 to 8.0 micron spectra are presented for two planetary nebulae nuclei Hen1044 (He2-113) and CPD-56 8032. The unidentified infrared (UIR) emission bands at 6.2 microns, 6.9 microns, 7.7 microns are present in the spectra of Hen1044 and in CPD-56 8032, and the 8.6 micron band is present in the long wavelength shoulder of the 7.7 micron band in the spectrum of CPD-56 8032. The 8 to 13 micron spectra of these two stars by Aitken et. al. clearly show the presence of the 8.6 micron band in He2-113 while weakly resolving this feature in the spectra of CPD-56 8032. In their spectra the 11.3 micron band is also clearly detected in both objects. The 6.2 micron and 7.7 micron bands are characteristic of the infrared active C-C stretching modes in polycyclic aromatic hydrocarbons (PAHs); the 3.3 micron, 8.6 micron, and 11.3 micron bands are respectively assigned to the in-plane stretching mode, the in-plane bending mode, and the out-of-plane bending mode of the aromatic CH bond. The weak 6.9 micron emission feature is attributed to the UIR spectrum by Bregman et. al. The IRAS LRS spectra of He2-113 (IRAS 14562-5406) and CPD-56 8032 (IRAS 17047-5650) are presented. Cohen et. al. identify the broad plateau from 11.3 to 13.0 microns in the spectrum of He2-113 with increased hydrogenation of PAHs. This broad plateau is not seen in the LRS spectrum of CPD-56 8032. Also, He2-113 has greater infrared excess emission in the 17-22 micron region than does CPD-56 8032.

Wooden, D. H.↗

Resolution of the 7.7 micrometers emission feature in NGC 7027

The unidentified infrared (UIR) features are a group of emission bands observed in a variety of objects, which can be characterized as having moderate density gas (densities from 1000 to 1,000,000/cu.cm.) and a nearby ultraviolet source. The origin of the features is still uncertain, but the current evidence points to Polycyclic Aromatic Hydrocarbons (PAHs) as the source of the UIR features. Problems with identifying PAHs as the source of the UIR features are discussed.

Bregman, J. D.↗

Multifrequency observations of the superluminal quasar 3C 345

Attention is given to the continuum properties of the superluminal quasar 3C 345, on the basis of radio, optical, IR, and X-ray frequency monitorings, as well as by means of simultaneous multifrequency spectra extending from the radio through the X-ray bands. Radio outbursts, which appear to follow IR-optical outbursts by about one year, first occur at the highest frequencies, as expected from optical depth effects; the peak flux is nevertheless often reached at several frequencies at once. The beginning of outbursts, as defined by mm-measurements, corresponds to the appearance of the three known 'superluminal' components. An increase in the X-ray flux during 1979-1980 corresponds to increased radio flux, while the IR flux changes in the opposite sense.

Bregman, J. N.↗

Emission features in the 4-13 micron spectra of the reflection nebulae NGC 7023 and NGC 2023

Spectroscopy from 4 to 13 microns of the visual reflection nebulae NGC 7023 and NGC 2023 has been obtained. These data, together with previous work from 1 to 4 microns, show that the spectra of these sources consist of a relatively flat continuum from 1 to 13 microns and six emission features at 3.3, 3.4, 6.2, 7.7, 8.6, and 11.3 microns. The observations rule out equilibrium thermal emission for the features and continuum in reflection nebulae, and point toward a nonequilibrium emission mechanism such as thermal emission from thermally fluctuating small grains or fluorescence from large molecules. The similarity of the emission feature spectra in reflection nebulae to those in other sources suggests a universal emission mechanism, thus implying nonequilibrium emission mechanisms in other sources.

Sellgren, K.↗

A cryogenically cooled, multidetector spectrometer for infrared astronomy

A liquid helium-cooled, 24 detector grating spectrometer was developed and used for low resolution astronomical observations in the 5 to 14 micron spectral range. The instrument operated on the 91 cm Kuiper Airborne Observatory, the 3 m IRTF (Mauna Kea), the 3 m Shane telescope (Lick Observatory), and the 152 cm NASA and University of Arizona telescope. The detectors are discrete Si:Bi photoconductors with individual metal oxide semiconductor field effect transistor preamplifiers operating at 4 K. The system uses a liquid helium-cooled slit, order-sorter filter, collimator mirror, grating, and camera mirror arranged in a Czerny-Turner configuration with a cold stop added between the collimator mirror and the grating. The distances between components are chosen so that the collimator mirror images the secondary mirror of the telescope onto the cold stop, thus providing a very effective baffle. Scattered radiation is effectively reduced by using liquid helium-cooled, black baffles to divide the spectrometer into three separate compartments. The system noise-equivalent flux density, when used on the 152 cm telescope from 8 to 13 microns with a resolving power of 50, is 4.4 x 10 to the minus 17th power W/sq cm micron square root of Hz. The main applications are for measuring continuum radiation levels and solid state emission and absorption features in regions of star and planet formation.

Witteborn, F. C.↗

A cryogenically cooled, multidetector spectrometer for infrared astronomy

A liquid helium-cooled, 24 detector grating spectrometer was developed and used for low resolution astronomical observations in the 5 to 14 micron spectral range. The instrument operated on the 91 cm Kuiper Airborne Observatory, the 3 m IRTF (Mauna Kea), the 3 m Shane telescope Observatory, the 3 m Shane telescope (Lick Observatory), and the 152 cm NASA and University of Arizona telescope. The detectors are discrete Si:Bi photoconductors with individual metal oxide semiconductor field effect transistor preamplifiers operating at 4 K. The system uses a liquid helium-cooled slit, order-sorter filter, collimator mirror, grating, and camera mirror arranged in a Czerny-Turner configuration with a cold stop added between the collimator mirror and the grating. The distances between components are chosen so that the collimator mirror images the secondary mirror of the telescope onto the cold stop, thus providing a very effective baffle. Scattered radiation is effectively reduced by using liquid helium-cooled, black baffles to divide the spectrometer into three separate compartments. The system noise-equivalent flux density, when used on the 152 cm telescope from 8 to 13 microns with a resolving power of 50, is 4.4 x 10 to the minus 17th power W/sq cm micron square root of Hz. The main applications are for measuring continuum radiation levels and solid state emission and absorption features in regions of star and planet formation.

Witteborn, F. C.↗

The unusual 8-13 micron spectrum of Markarian 231

An 8-13 micron spectrum was obtained of the Seyfert galaxy Markarian 231 with a spectral resolution of 0.22 micron per point. The spectrum is unlike any previously published spectrum at these wavelengths. The spectrum can be attributed to a combination of absorption and reemission by crystalline silicates which must have formed under conditions quite different from those in which silicates form in the Galaxy. Comparison of the data with previously published data indicates that the infrared emission is extended and not dominated by a bright central source.

Bregman, J. D.↗

Observations of NGC 7027 from 5.2 to 7.5 microns - The detection of Ni II and additional dust features

NGC 7027 was observed with a multichannel grating spectrometer from 5.2 to 7.5 microns at a spectral resolving power of 120-200. Two new dust emission features are resolved at 5.62 and 6.95 microns, and for the first time the Ni II fine-structure line at 6.64 microns is detected. It is shown that a single molecular dust constituent might account for six of the nine observed dust features between 2 and 14 microns. The strength of the Ni II line indicates either that Ni is not depleted in the neutral gas, or that the line is formed at high density.

Bregman, J. D.↗

The C2H, C2, and CN electronic absorption bands in the carbon star HD 19557

Infrared spectrophotometry of the R-type carbon star HD 19557 is presented. Two unusual spectroscopic features are seen: a 3.1 micron band is lacking and a 2.8 micron band is present. Identifications are proposed for three previously unreported stellar absorption bands with electronic sequences of C2, CN, and C2H. The latter is proposed to be responsible for the 2.8 micron feature. The atmospheric structure of the star is studied with synthetic spectra, and an effective temperature between 2600 K and 3000 K is suggested. No SiC emission is seen at 11.3 microns, indicating that grain formation is not a viable process around the star. The lack of dust in R stars may suggest a salient difference between R and N types.

Goebel, J. H.↗

A search for fragmentation debris near Ursa Major Stream stars

Accretion models of planet formation and the early cratering history of the solar system suggest that planet formation is accompanied by a cloud of debris resulting from accumulation and fragmentation. A rough estimate of the infrared luminosities of debris clouds is presented for comparison with measured 10-micron luminosities of young stars. New measurements of 13 F, G, and K main-sequence stars of the Ursa Major Stream, which is thought to be about 270-million years old, place constraints on the amount of debris which could be present near these stars.

Witteborn, F. C.↗

Low-background performance of a monolithic InSb CCD array

A 20 element monolithic InSb charge coupled device (CCD) detector array was measured under low background conditions to assess its potential for orbital astronomical applications. At a temperature of 64 K, previous results for charge transfer efficiency (CTE) were reproduced, and a sensitivity of about 2 x 10 to the minus 15th power joules was measured. At 27 and 6 K, extended integration times were achieved, but CTE was substantially degraded. The noise was approximately 6000 charges, which was in excess of the level where statistical fluctuations from the illumination could be detected. A telescope demonstration was performed showing that the array sensitivity and difficulty of operation were not substantially different from laboratory levels. Ways in which the device could be improved for astronomical applications were discussed.

Bregman, J. D.↗

The abundance of argon at the galactic center

Measurements of forbidden line Ar II 6.99 micron and Pf alpha 7.45 micron made from the Kuiper Airborne Observatory are presented for Sgr A, the H II region at the center of the Galaxy. These line strengths, when combined with ground-based measurements, suggest a factor of enhancement of two in the Ar/H ratio in the galactic center region relative to that in the sun and in the solar neighborhood. The accuracy of the determination is presently limited by the uncertainty in the collision strength for Ar(+).

Lester, D. F.↗