Engineering Papers⌕ Search

Engineering topics

Brandt, J.

Publications and source records attributed to Brandt, J..

The DAMIC-M Low Background Chamber

The DArk Matter In CCDs at Modane (DAMIC-M) experiment isdesigned to search for light dark matter (m$_{χ}$ < 10 GeV/c$^{2}$)at the Laboratoire Souterrain de Modane (LSM) in France. DAMIC-Mwill use skipper charge-coupled devices (CCDs) as a kg-scale activedetector target. Its single-electron resolution will enable eV-scaleenergy thresholds and thus world-leading sensitivity to a range ofhidden sector dark matter candidates. A DAMIC-M prototype, the LowBackground Chamber (LBC), has been taking data at LSM since2022. The LBC provides a low-background environment, which has beenused to characterize skipper CCDs, study dark current, and measureradiopurity of materials planned for DAMIC-M. It also allows testingof various subsystems like readout electronics, data acquisitionsoftware, and slow control. This paper describes the technicaldesign and performance of the LBC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experiments On Electron Cooling and Intense Space-charge at IOTA

The Integrable Optics Test Accelerator at Fermilab will explore beam dynamics in a ring with intense space-charge using 2.5 MeV proton beams with an incoherent tune shift approaching -0.5. We will use this machine to explore the interplay between electron cooling, intense space-charge, and coherent instabilities. In this contribution, we describe the machine setup including the design of the electron cooler and the lattice, list specific experiments and discuss the results of numerical simulations which include the effects of electron cooling and transverse space-charge forces.

43 PARTICLE ACCELERATORS↗

EXPERIMENTS ON ELECTRON COOLING AND INTENSE SPACE-CHARGE AT IOTA

The Integrable Optics Test Accelerator at Fermilab will explore beam dynamics in a ring with intense space-charge using 2.5 MeV proton beams with an incoherent tune shift approaching -0.5. We will use this machine to explore the interplay between electron cooling, intense space-charge, and coherent instabilities. In this contribution, we describe the machine setup including the design of the electron cooler and the lattice, list specific experiments and discuss the results of numerical simulations which include the effects of electron cooling and transverse space-charge forces.

Banerjee, N.↗

Thermionic Sources for Electron Cooling at IOTA

We are designing and fabricating two new thermionic sources of magnetized electrons for use in the electron lens project in the Integrable Optics Test Accelerator (IOTA) at Fermilab. These electron sources will be used for cooling 2.5 MeV protons. One source will be used to compensate for emittance growth due to Intra Beam Scattering in experiments with weak space-charge, while the other source will be used to research the interplay between electron cooling and intense space charge. In this paper we present the progress made so far and the upcoming steps for the thermionic electron sources.

43 PARTICLE ACCELERATORS↗

Commissioning of the Low Energy Electron Gun Test Stand at the University of Chicago

We built a test stand for evaluating the performance of the thermionic electron sources for the electron lens project at the Integrable Optics Test Accelerator (IOTA) in Fermilab. The lens will be used to study nonlinear dynamics and electron cooling of 2.5 MeV protons with strong space charge. The test stand will validate the characteristics of the thermionic sources and the main parameters of the generated beams. In this paper we present the results of the commissioning of the UChicago test stand and validation of the hollow beam source.

43 PARTICLE ACCELERATORS↗

The DAMIC-M experiment: Status and first results

The DAMIC-M (DArk Matter In CCDs at Modane) experiment employs thick, fully depleted silicon charged-coupled devices (CCDs) to search for dark matter particles with a target exposure of 1 kg-year. A novel skipper readout implemented in the CCDs provides single electron resolution through multiple non-destructive measurements of the individual pixel charge, pushing the detection threshold to the eV-scale. DAMIC-M will advance by several orders of magnitude the exploration of the dark matter particle hypothesis, in particular of candidates pertaining to the so-called “hidden sector.” A prototype, the Low Background Chamber (LBC), with 20g of low background Skipper CCDs, has been recently installed at Laboratoire Souterrain de Modane and is currently taking data. We will report the status of the DAMIC-M experiment and first results obtained with LBC commissioning data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Incoherent Dynamics of Intense Proton Beams Under Electron Cooling

The minimum emittance of ion beams achieved using electron cooling is limited by the heating processes of Intra Beam Scattering and diffusion driven by resonance crossing of particles due to space-charge. We describe a new experiment to explore the intense space-charge regime with a transverse tune shift approaching -0.5 using 2.5 MeV protons at the Integrable Optics Test Accelerator (IOTA) at Fermilab. We also report on the results from PyORBIT simulations incorporating transverse space-charge and electron cooling with emphasis on the incoherent dynamics of the particles.

43 PARTICLE ACCELERATORS↗

Incoherent Dynamics of Intense Proton Beams under Electron Cooling

The minimum emittance of ion beams achieved using electron cooling is limited by the heating processes of Intra Beam Scattering and diffusion driven by resonance crossing of particles due to space-charge. We describe a new experiment to explore the intense space-charge regime with a transverse tune shift approaching -0.5 using 2.5~MeV protons at the Integrable Optics Test Accelerator (IOTA) at Fermilab. We also report on the results from PyORBIT simulations incorporating transverse space-charge and electron cooling with emphasis on the incoherent dynamics of the particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mu2e Run I Sensitivity Projections for the Neutrinoless Conversion Search in Aluminum

The Mu2e experiment at Fermilab will search for the neutrinoless conversion in the field of an aluminum nucleus. The Mu2e data-taking plan assumes two running periods, Run I and Run II, separated by an approximately two-year-long shutdown. This paper presents an estimate of the expected Mu2e Run I search sensitivity and includes a detailed discussion of the background sources, uncertainties of their prediction, analysis procedures, and the optimization of the experimental sensitivity. The expected Run I discovery sensitivity is , with a total expected background of events. In the absence of a signal, the expected upper limit is at 90% CL. This represents a three order of magnitude improvement over the current experimental limit of at 90% CL set by the SINDRUM II experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermionic Sources For Electron Cooling At IOTA

We are designing and fabricating two new thermionic sources of magnetized electrons for use in the electron lens project at the Integrable Optics Test Accelerator (IOTA) at Fermilab. These electron sources will be used for cooling of 2.5 MeV protons in the presence of intense space-charge. Furthermore, we are constructing an electron source test stand at the University of Chicago which will validate the electrical, thermal, and vacuum characteristics of thermionic sources. In this paper we present the progress made so far and the upcoming steps for the thermionic electron sources for electron cooling and the test stand.

43 PARTICLE ACCELERATORS↗

Fabrication and installation of the Mu2e cryogenic distribution system

The muon-to-electron conversion (Mu2e) experiment at Fermilab will be used to search for the charged lepton flavor-violating conversion of muons to electrons in the field of an atomic nucleus. The Mu2e experiment is currently in the construction stage. The scope of this paper is the cryogenic distribution system and superconducting power leads for four superconducting solenoid magnets: Production Solenoid (PS), an Upstream and Downstream Transport Solenoids (TSu and TSd) and Detector Solenoid (DS). The design of the cryogenic distribution system and the fabrication of several sub-systems was reported previously. This paper reports on additional fabrication and installation progress that has been performed over the past two years. Lessons learned during fabrication and testing of the cryogenic distribution system components are described. In particular, the challenges and solutions implemented for aluminum welding are reported. A description of the process used to qualify the welding procedure and welders for welding the aluminium stabilized NbTi superconducting power leads is provided. Additionally, the progress made with regards to installing the power leads into the cryogenic Feedboxes is covered.

White, Michael J.↗

The Population of Small Comets: Optimum Techniques for Detection

The goals of this project were: (1) to present evidence to the scientific community for the importance of the small comet population and (2) to develop techniques for optimum detection in order to characterize the population. The work has been carried out by D. Schleicher (Lowell Observatory), M. A'Hearn and Y. Fernandez (University of Maryland), I.A.F. Stewart, C. Randall, and J. Brandt (University of Colorado).

Schleicher, D.↗

Manufacture and performance of carbon/epoxy 3-D woven composites

This paper evaluates 3-D orthogonal woven carbon/epoxy composites. Preforms were manufactured on an automatic 3-D weaving machine developed at N.C. State University. Matrix infiltration was conducted at MBB Central Laboratories. Testing was carried out at both locations and the joint results will be reported. The properties investigated include: interlaminar shear strength, compression, compression after impact, bending, tensile and penetration resistance. The 3-D orthogonal woven composites were compared with laminated and other 3-D composites made with preforms having interlock structure. C-scans were used to examine the quality of infiltration and the damage area after impact. The performance of the composites made from the 3-D orthogonal preforms showed superior properties compared to the other composites. The penetration resistance test showed unexpectedly very good performance.

Brandt, J.↗