Engineering Papers⌕ Search

Engineering topics

Brandenburg, S

Publications and source records attributed to Brandenburg, S.

SU-C-204-07: The Production of Short-Lived Positron Emitters in Proton Therapy

Purpose: To investigate the production and effect of short-lived positron emitters when using PET for in-vivo range verification during a proton therapy irradiation. Methods: The integrated production of short-lived positron emitters in the stopping of 55 MeV protons was measured in water, carbon, phosphorus and calcium targets. The experimental production rates are used to calculate the production on PMMA and a representative set of 4 tissue materials. The number of decays integrated over an irradiation in these materials is calculated as function of the duration of the irradiation, considering irradiations with the same total number of protons. Results: The most copiously produced short-lived nuclides and their production rates relative to the relevant long-lived nuclides are: 12-N (T1/2 = 11 ms) on carbon (9.5% of the 11-C production), 29-P (T1/2 = 4.1 s) on phosphorus (20% of the 30-P production) and 38m-K (T1/2 = 0.92 s) on calcium (113% of the 38g-K production). No short-lived nuclides are produced on water. The most noticeable Result is that for an irradiation in (carbon-rich) adipose tissue, 12-N will dominate the PET image up to an irradiation duration of 70 s. On bone tissue, 15-O dominates over 12-N after 7–15 s (depending on the carbon-to-oxygen ratio). Conclusions: The presence of 12-N needs to be considered in PET imaging during proton beam irradiations as, depending on tissue composition and PET scanning protocol, it may noticeably deteriorate image quality due to the large positron range blurring. The results presented warrant investigations into the energy-dependent production of 12-N, 29-P and 38m-K and their effect on PET imaging during proton irradiations.

60 APPLIED LIFE SCIENCES↗

Study of ion beam extraction and transport from an electron cyclotron resonance ion source

We have started an experimental and theoretical program to better understand the extraction and transport of intense multiply charged ion beams from an electron cyclotron resonance ion source (ECRIS). In this paper we present the first results of this program concerning a simple, monocomponent He{sup +} beam extracted from an ECRIS. We have calculated the ion trajectories starting from the ECRIS plasma electrode up to the image plane of the analyzing magnet taking into account space-charge effects and fringe fields. The initial phase-space distribution of the He{sup +} beam at the extraction aperture has been calculated with a particle-in-cell code. To check the simulations we have measured beam profiles with a viewing screen both before and after the analyzing magnet. In addition also measurements with a pepperpot emittance meter located behind the analyzing magnet have been performed. We find good agreement between these measurements and simulations showing that (i) there is a significant compensation of the space charge and that (ii) our analyzing magnet causes a severe increase in effective beam emittance.

43 PARTICLE ACCELERATORS↗

R-matrix analysis of the {beta} decays of {sup 12}N and {sup 12}B

The {beta} decays of {sup 12}N and {sup 12}B have been studied at KVI and JYFL to resolve the composition of the broad and interfering 0{sup +} and 2{sup +} strengths in the triple-{alpha} continuum. For the first time a complete treatment of 3{alpha} decay is presented including all major breakup channels. A multilevel, many-channel R-matrix formalism has been developed for the complete description of the breakup in combination with the recently published separate analysis of angular correlations. We find that, in addition to the Hoyle state at 7.65 MeV, more than one 0{sup +} and 2{sup +} state is needed to reproduce the spectra. Broad 0{sub 3}{sup +} and 2{sub 2}{sup +} states are found between 10.5 and 12 MeV in this work. The presence of {beta} strength up to the {sup 12}N Q-value window suggests the presence of additional 0{sup +} and 2{sup +} components in the {sup 12}C structure at energies above 12.7 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precise Branching Ratios to Unbound 12C States from 12N and 12B (beta)-Decays

Two complementary experimental techniques have been used to extract precise branching ratios to unbound states in {sup 12}C from {sup 12}N and {sup 12}B {beta}-decays. In the first the three {alpha}-particles emitted after {beta}-decay are measured in coincidence in separate detectors, while in the second method {sup 12}N and {sup 12}B are implanted in a detector and the summed energy of the three {alpha}-particles is measured directly. For the narrow states at 7.654 MeV (0{sup +}) and 12.71 MeV (1{sup +}) the resulting branching ratios are both smaller than previous measurements by a factor of {approx_equal} 2. The experimental results are compared to no-core shell model calculations with realistic interactions from chiral perturbation theory, and inclusion of three-nucleon forces is found to give improved agreement.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ion source development at KVI

Ion source development at KVI is focused on increasing the beam intensity from the electron cyclotron resonance ion source injector and optimizing the beam transport and injection into the superconducting AGOR cyclotron. We describe several modifications that have resulted in a significant performance increase of the ion source. We also present the first results of ion transport simulations that have been performed to better understand beam losses in the extraction region and in the low-energy beam transport system. Finally, a new emittance meter based on a combination of the pepperpot and scanning techniques will be described, which will be used to benchmark the simulation studies of ion extraction and transport in detail.

43 PARTICLE ACCELERATORS↗