Engineering Papers⌕ Search

Engineering topics

Brambley, Michael R.

Publications and source records attributed to Brambley, Michael R..

Zero-Emissions Roadmap for Oakland County

This document outlines a strategic pathway for Oakland County, Michigan to achieve zero emissions by 2050 under the Clean Energy to Communities (C2C) Program. The report encompasses analyses and high-level modeling to guide Oakland County in its emission reduction goals. Key methods include establishing an emissions inventory baseline with ongoing evaluation of future projects’ emissions impacts. Core elements include decommissioning old infrastructure, enhancing energy efficiency, deploying hybrid and ground-source heat pumps, and transitioning to electric fleets. It is proposed to structure the planning process into 5-year strategic plans to make the decarbonization process manageable. The document also emphasizes the need for reassessment of goals and periodic updates to remain adaptive to technological advancements and funding considerations. A matrixed approach for evaluating projects by cost and emissions savings is suggested to optimize decision-making given finite resources.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Event-Based Energy Impact Tracking and Forecasting with Limited Measurements for Rooftop Units

Packaged air conditioning units and heat pumps, also known as rooftop units (RTUs), are responsible for almost 133 billion kWh of electricity usage annually on site for space cooling U.S. commercial buildings. In addition, the use of heat pumps is a trend we expect to accelerate as buildings transition from fossil fuel-based heating to electricity as a key step for decarbonizing the U.S. commercial buildings sector. However, the operation conditions and energy use of RTUs and heat pumps are usually not well monitored as they are not commonly integrated with building automation systems and lack exposed sensing and control points. To fill this gap, this paper proposes a framework for tracking and forecasting energy impacts resulting from degradation of performance and improved performance for unit servicing using limited data. The proposed framework makes use of a constrained dataset, specifically measurements of the outdoor air temperature and the power demand of individual RTUs, to track and forecast changes in energy use associated with changes in performance over various temporal horizons ranging from days to weeks. Following the detection of an RTU fault, performance degradation, or performance improvement, the framework employs a prediction model to assess the cumulative energy impact. We demonstrate the effectiveness of the method with field-collected data for servicing and degradation examples and compare the predicting accuracy of Gradient Boosting Decision Tree (GBDT) Regression models to Support Vector Regression and Linear Regression models. The results show that GBDT achieved the best accuracy for time-series validation datasets for the servicing and degradation cases, and the prediction model was able to track the cumulative energy impacts of events. The proposed framework can inform building owners of the cumulative change in energy usage of RTUs associated with performance degradation, performance improvement, or a fault.

packaged air conditioners, packaged heat pumps, ro↗

DOE Cold Climate Heat Pump Challenge Field Validation: Data Collection and Analysis Plan

This document details the data collection, storage, and analysis plan and methodologies for conducting the field validation portion of DOE’s Cold Climate Heat Pump (CCHP) Challenge. The study is focused on validating the in-field heating performance of prototypical CCHPs that have successfully demonstrated that they meet or exceed the Challenge specification in a laboratory setting. The units that have passed laboratory testing will be installed in real homes along with sensors and loggers for monitoring performance over an entire heating season. Data collected through monitoring will be cleaned and stored in a secure database. The data will be analyzed for calculating the key metrics defined by the Challenge including heating capacities at low outdoor air temperatures (below 32 °F), efficiency in terms of the Coefficient of Performance (COP), switchover temperatures and auxiliary heat staging. Demand Response (DR) capabilities will also be tested using specially designed DR events. In most cases, shoulder season and cooling season performance will also be determined and reported.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Testing and validating SMDS algorithms implemented in the cloud

Pacific Northwest National Laboratory (PNNL) provided technical assistance to NorthWrite Inc. under the Small Business Vouchers (SBV) Pilot. NorthWrite delivered services to owners of small commercial buildings, using a cloud-based service to monitor, control, and optimize building operations, saving energy and reducing operating costs for the owners while ensuring that occupant comfort needs were consistently met. NorthWrite had a longstanding desire to add a new suite of diagnostic capabilities to their service offering and had been trying, without success, to incorporate several diagnostic algorithms published by PNNL. These algorithms arise from research previously supported by BTO. Through the SBV awarded to NorthWrite, PNNL made available technical knowledge regarding the derivation and application of the following sets of algorithms for use in the NorthWrite Cloud-based service delivery system: • algorithms for monitoring rooftop packaged air conditioners and heat pumps (often referred to as rooftop units or RTUs) and diagnosing faults in these units, • advanced algorithms for automated fault detection and diagnosis of other equipment found in small buildings, and • algorithms for identifying, prioritizing, and assessing the economic effectiveness of implementing energy saving measures in small commercial buildings based on sensed data. The PNNL researchers involved were the original developers of these algorithms, had a unique understanding of the derivation of the algorithms, and had the source data used for this derivation. Further, the PNNL researchers had extensive experience using these algorithms in the laboratory, unique experience applying these algorithms in real-world small commercial buildings and could solve a number of key problems that NorthWrite and other users faced in using these algorithms at scale. In addition, PNNL had recently installed a pair of RTUs in a laboratory setting that were instrumented and connected with data acquisition systems that provided a unique test rig for validating the algorithms before NorthWrite began to deploy their new services in the field.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FREQUENCY REGULATION WITH CONNECTED LIGHTING SYSTEMS

The management of end-use energy resources, e.g., commercial buildings, has been investigated as a promising source of services for the electric power grid. Lighting consumes about 17% electricity of U.S. commercial buildings; however, it may contribute significantly to services that improve the reliability and resilience of the grid due to its rapid speed of response. Connected lighting systems (CLS), which build upon solid-state lamp technology, can change their power demand more quickly than most other building electricity end uses. But the potential of CLS to provide grid services has not been considerably investigated. In this paper, we describe initial research to evaluate the potential of CLS for the grid service of frequency regulation. Frequency regulation is a reliability product that corrects in a matter of seconds for short-term changes in the balance between supply and demand in the balancing area that might affect the stability of the power system. Frequency regulation signals for a medium office building are generated from the normalized test signals for the PJM Interconnection Reg-A and Reg-D regulations services. Control of the CLS locally to follow the Reg-A or Reg-D signal is used to provide contributions to the corresponding frequency regulation service. The performance of CLS for frequency regulation is evaluated using the PJM 40-Minute Performance Score Template. The performance scores obtained for all CLS categories for both Reg-A and Reg-D signals far exceed the minimum score for the qualification, a very promising result for CLS to provide frequency regulation service.

Wang, Peng↗

Retro-Commissioning Sensor Suitcase for Energy Efficiency

This project will enable Pacific Northwest National Laboratory (PNNL) and Lawrence Berkeley National Laboratory (LBNL) to work with industry partner, GreenPath Energy Solutions, joint developers of the Suitcase, to enhance the capabilities and usability of the Retro-Commissioning Sensor Suitcase (hereinafter the Sensor Suitcase or Suitcase), assisting GreenPath to take the Suitcase to market and rapidly expand their market share. The proposed project will specifically focus on 1) adding sensors types to extend the data collection capability and support more building and equipment performance metrics and identification of even more energy saving opportunities, 2) developing algorithms to identify recommendations for the new energy savings opportunities from item 1 and to prototype software modifications implementing them, 3) validating the use of vibration sensors to detect the operating state of a broader set of packaged HVAC equipment (additional capacities, different numbers of stages, etc.) than tested in initial development and modifying the state algorithm and software code, as needed, 4) improving cost-effectiveness in manufacturing the Sensor Suitcase, and 5) additional field testing of the technology in real buildings to more comprehensively validate Suitcase performance and to guide refinement of its capabilities. Project results will position GreenPath, and potential future licensees, to implement the new capabilities developed in this project in GreenPath’s RCx Building Suitcase, increasing its functionality and the savings resulting from its use. These enhancements will increase the value of the Suitcase to users and increase the potential market for its use and impacts in that impact.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Smart Monitoring and Diagnostic System (SMDS) for Packaged Air Conditioners and Heat Pumps for Small/Medium Commercial Buildings: Preparation for Commercialization: CRADA 478 [Abstract only]

This project will enable Pacific Northwest National Laboratory (PNNL) and industry partner, mCloud Technologies, to work collaboratively to ready the Smart Monitoring and Diagnostic System (SMDS) for commercial deployment and validate its performance under real-world conditions at field sites. This project will specifically focus on 1) implementing the SMDS algorithms in a scalable cloud-based software architecture, 2) designing new, innovative, complimentary commercial services based on the SMDS, 3) enhancing the SMDS energy and cost impact algorithms to reduce uncertainty in estimates, 4) determining the lower limits on SMDS performance degradation detection, 5) validating algorithm performance and default values of adjustable thresholds with existing data from controlled physical testing and from customer packaged air conditioners and heat pumps (commonly referred to as rooftop units or RTUs), 6) field testing to validate the system on multiple customer buildings in diverse environments, and 7) expanding field deployment to a larger set of mCloud’s customer buildings. Project results by validating, enhancing, and quantifying the performance of the SMDS will position mCloud, and potential future licensees, to implement the SMDS in commercial offerings that encourage and enable use of condition-based and predictive maintenance, leading to significant reductions in energy use and greenhouse gas emissions associated with space conditioning by RTUs. Furthermore, these enhancements will increase the value of the SMDS for users and increase the potential market for its use and impacts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of Connected Lighting System Potential for Grid Services Under Real-Time Pricing

Increasingly over the last decade, the management of end-use electricity demand has been examined as a potential source of services for the electric power grid beyond contracts with large commercial and industrial customers. Lighting represents about 17\% of U.S. commercial building annual electricity consumption; however, its potential rapid speed of response may position it to uniquely contribute to services that improve the reliability and resilience of the grid. Connected lighting systems (CLS), which build upon solid-state lamp technology, can change state by adjusting power demand more quickly than most other building electricity end uses and could be used as a platform to monitor lighting electricity use and space conditions. But the potential of CLS to provide grid services has not been extensively studied. In this paper, we describe initial research to evaluate the potential of CLS for grid services. We develop a model for CLS using a set of parameters to represent operation behaviors and constraints: maximal power, minimal power, nominal power, ramp rate, and time delay. Parameter values are generated for representative building types. CLS demand curves are constructed, indirectly capturing building occupant preferences for lighting as functions of electricity price. The CLS model and the demand curves are incorporated into a Transactive Control and Coordination (TCC) Platform to simulate CLS providing grid services. Previous research has shown TCC to be a powerful tool to enable end uses to provide grid services through a hybrid economic-control approach. Initial quantitative results will be provided for CLS grid services potential.

Wang, Peng↗

Performance Simulation and Analysis of Occupancy-Based Control for Office Buildings with Variable-Air-Volume Systems

Variable-air-volume (VAV) systems are used in many office buildings. The minimum airflow rate setting of VAV terminal boxes has a significant impact on both energy consumption and indoor air quality. Conventional controls usually have the terminal’s minimum airflow rate at a constant (e.g., 30% or more of the terminal design airflow rate), irrespective of the occupancy status, which may cause problems, such as excessive simultaneous heating and cooling, under ventilation, and thermal comfort issues. This paper examines the potential of energy savings from occupancy-based controls (OBCs). The sensed occupancy information, either occupant presence or people count, is used to determine the airflow rate of terminal boxes, the thermostat setpoints, and the lighting control. Using EnergyPlus, a whole-building energy modeling software, the energy savings of OBC strategies are evaluated for representative existing medium office buildings in the U.S. The simulation results show that the conventional OBC, based on occupant presence sensing, can save 8% of whole-building energy use in Miami (hot climate) for systems without air-side economizer and about 13% in both Baltimore (mixed climate) and Chicago (cold climate). Comparatively, the advanced OBC, based on people counting, can save 8% in Miami to 23% in Baltimore for systems with economizers. The outdoor-air fraction of the supply air from air-handling units significantly affects the potential energy savings from the advanced OBC strategy. In addition to energy savings, the advanced OBC satisfies the zone ventilation during all occupied hours over the whole year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Savings of Occupancy-Based Controls in Office Buildings

Variable-air-volume (VAV) systems are used in many office buildings. The terminal’s minimum air flowrate set point is an important parameter that has significant impact on energy consumption and indoor air quality. Conventional controls usually have the terminal’s minimum air flowrate at a constant, irrespective of the occupancy status. Such practice may cause energy waste, ventilation and thermal comfort problems. This paper examines the potential of energy savings by occupancy-based controls (OBCs). The sensed occupancy information, either presence or the people count, is used to determine the air flowrate of terminal boxes, the thermostat set points, and the lighting as well. Using EnergyPlus, energy savings of OBC strategies are evaluated for representative existing medium office buildings in the U.S. Simulation results show that for the location of Baltimore, MD, the use of air-side economizer or not does indeed have significant impact on the comparison between the two OBC strategies. The OBC based on the occupant presence has about 13% whole-building energy savings no matter whether the air-side economizer is used in the AHU operation. However, for the OBC based on the people count, the percentage of energy savings increases from 13% for the case of not using air-side economizer to 23% for the case of using air-side economizer.

Occupancy based control, building simulation, adva↗

Predicting Home Thermal Dynamics Using a Reduced-Order Model and Automatied Real-Time Parameter Estimation

Although smart thermostats have increasingly provided homeowners with abundant operational data related to advanced HVAC control and energy usage management in homes, there is a lack of systematic frameworks that can utilize such data to generate actionable information for advanced home comfort system diagnosis and control. Recognizing that a home thermal model, which is capable of connecting weather and HVAC operational data, is crucial to this framework, this paper introduces a home thermal model that is built upon the standard RC (Resistor-Capacitor) approach and the one virtual envelope assumption to describe the thermal dynamics of a home. A parameter estimation scheme is also developed that enables automatic, sequential, and optimal estimation of the model parameters, i.e., the thermal properties, of a home. Finally, the home thermal model and its parameter estimation scheme are tested using data collected over 63 consecutive days from a test home. In the test, the length of data that can provide enough robustness for parameter estimation is investigated. It is found that 10 days of data are enough, although 20 or more days of data can provide more robust results. In addition, when the model is used to make 12-hour-ahead predictions of indoor temperature the resulting mean, maximum, and 95%-confidence-interval absolute are 0.31 °C, 1.72 °C, and 0.90 °C, respectively, if the model is trained using 10 consecutive days of data, and 0.27 °C, 1.19 °C, and 0.72 °C, respectively, if 20 consecutive days are used. Therefore, the proposed home thermal model requires only a modest amount of training data to yield fairly accurate prediction and is able to perform better with more data.

home thermal model, Building thermal dynamics, ind↗

Building environment data collection systems

Building environment data collection systems and methods are described. According to one aspect, a system includes a plurality of sensor devices which store different types of environment data, a base system comprising a plurality of interface devices configured to receive the environment data from the sensor devices, storage circuitry configured to store the environment data, and communications circuitry configured to implement communications, and a user interface apparatus comprising communications circuitry configured to communicate with the communications circuitry of the base system, a user interface configured to receive user inputs during installation of the sensor devices, and processing circuitry configured to control the user interface to generate the displayed information and to process the user inputs received via the user interface, and wherein different ones of the sensor devices are configured to generate the different types of environment data as a result of the user inputs.

Hughes, Michael A.↗

An agent-based hardware-in-the-loop simulation framework for building controls

In general, a hardware-in-the-loop (HIL) building simulation has lower cost and fewer practical limitations (e.g., scheduling issues) than field tests in occupied buildings, while also overcoming limitations of simulations alone by capturing the full behavior of some physical systems, equipment, and components. However, the implementation of an HIL can be difficult due to the scarcity of appropriate tools. Here, this paper presents an agent-based framework for HIL simulation. It can be used for investigation of controller performance via controller-in-the-loop simulations and also HIL for system synthesis. In the latter case, both controllers and major equipment participate in tests to ensure that dynamics of equipment operation are correctly captured in addition to controller performance. The HIL simulation framework presented allows such actual physical parts to be included in the framework while representing others for which behaviors are better known and modeled in simulation models. The mechanism implemented in the framework to synchronize simulations in software with real-time operation of physical equipment is described. Lastly, as an example, use of the HIL simulation framework is illustrated through a brief study of speed control of the supply fan in the air handling unit of a variable-air-volume building heating, ventilating and air-conditioning system.

42 ENGINEERING↗