Engineering PapersSearch

Engineering topics

Brace, L. H.

Publications and source records attributed to Brace, L. H..

At least 19 records

The nightward ion flow scenario at Venus revisited

We indicate how existing Pioneer Venus Orbiter (PVO) data might be used to gain a better understanding of nightward ion flow in the Venusian ionosphere. Calculations based on PVO measurements made at solar maximum suggest that the global nightward flow of O(+) may be signifcantly greater than is required to maintain the observed nightside ionosphere densities. The validity of this conclusion depends upon (1) the accuracy with which the flow can be determined from the PVO ion density and velocity measurements and (2) the validity of the ionosphere theory used to estimate the required downward O(+) flux on the night side. If the measurements and theory are assumed to be accurate, the excess nightward flow implies a significant rate of ion escape from the planet, particularly at times of low solar wind dynamic pressure, Psw, when the ionopause rises to allow increased nightward flow. To illustrate a potentially important mechanism for ion escape from Venus, we present Orbiter Electron Temperature Probe (OETP) observations of plasma clouds and scavenged ionospheric plasma observed above the ionopause. We then employ OETP and Orbiter Retarding Potential Analyzer (ORPA) data to reexamine the global ion flow for average Psw conditions.

Brace, L. H.

Evidence for ion transport and molecular ion dominance in the Venus ionotail

We present analyses from the five Pioneer Venus Orbiter plasma experiments and the plasma wave experiment when a patch of plasma with enhanced densities was encountered in the near-Venus ionotail during atmospheric entry at an altitude of approximately 1100 km in the nightside ionosphere. Our analyses of the thermal and superthermal ion measurements in this plasma feature provides the first evidence that at times molecular ions in the 28-32 amu mass range are dominant over atomic mass species thus yielding evidence for a transport mechanism that reaches into the lower ionosphere. Analysis of plasma analyzer (OPA) observations at this time indicates the presence of ions measured in the rest frame of the spacecraft at approximately 27 and 37 volt energy per unit charge steps. In the rest frame of the planet these superthermal ions are flowing from the dawn direction at speeds (assuming they are O2(+)) of approximately 8 km/s and with a flow component downward (perpendicular to the ecliptic plane) at speeds of approximately 2 km/s. OPA analyses also determine the ion number flux, energy, flow angles, and angular distributions. Plasma wave bursts appear to indicate that plasma density decreases within and on the equatorward edge of the patch of enhanced plasma densities are associated with ion acoustic waves and relative ion streaming.

Intriligator, D. S.

Localized injection of large-amplitude Pc 1 waves and electron temperature enhancement near the plasmapause observed by DE2 in the upper ionosphere

The relation between electron temperature enhancement and large amplitude Pc 1 wave injections in the upper ionosphere is investigated using the data obtained by the Dynamics Explorer 2 spacecraft. Results can be summarized as follows: (1) The region of the temperature enhancement coincides with that of the wave injection which is latitudinally very narrow (less than 100 km) in comparison with the wavelength along the ambient magnetic field (several hundred kilometers). (2) The duration of the wave injection (or the temperature enhancement) seems to be less than a few hours even under quiet geomagnetic conditions, and/or the injection seems to be very localized, not only latitudinally, but also longitudinally. (3) The appearance and the magnitude of temperature enhancement depend on both the wave amplitude and the satellite altitude. (4) Two of the 22 events that were analyzed show a clear enhancement of low-energy electron flux (5 to 30 eV) at the wave injection, and the flux is field-aligned both downward and upward. The region of the temperature enhancement coincides with that of the downward electron flux. From these results, it is suggested that the temperature enhancement which accompanies large-amplitude waves with Pc 1 pulsation frequencies (0.2 to 5 Hz) is caused by the direct acceleration of thermal electrons at low altitudes by the parallel electric field (0.01 to 0.001 mV/m) of the ion-cyclotron waves (kinetic Alfven waves) having an oblique wave normal.

Iyemori, T.

The magnetic state of the lower ionosphere during Pioneer Venus entry phase

During the entry phase of the Pioneer Venus Orbiter (PVO), defined as that period at the end of mission in 1992 when the periapsis fell below 185 km, the magnetometer made repeated measurements throughout the post midnight ionosphere until about 0430 LT. In this region the magnetic field is generally stronger at comparable altitudes than it was earlier at times of higher solar activity. This increase combined with a decrease in electron density causes the ratio of the magnetic pressure to thermal pressure to approach unity at altitudes above 200 km, whereas it was much lower than unity at these altitudes during solar maximum. From 160-200 km the magnetic field pressure exceeds that of the ionospheric plasma quite unlike the usual conditions seen at the beginning of the mission. At lowest altitudes below 150 km, however, the field becomes weaker and hence no evidence for a planetary magnetic field is found.

Russell, C. T.

The nightside ionosphere of Venus under varying levels of solar EUV flux

Solar activity varied widely over the 14 year lifetime of the Pioneer Venus Orbiter (PVO), and these variations directly affected the properties of the nightside ionosphere. At solar maximum, when solar EUV was largest, the Venus ionosphere was found to extend to highest altitudes and nightward ion transport was the main source of the nightside ionosphere. At solar minimum, nightward ion transport was reduced, and electron precipitation was thought to be the main source. In this study, we have attempted a separation of spatial variations from temporal variations by examining the altitude profiles of the magnetic field, and electron density and temperature for three different solar EUV flux ranges. In the upper ionosphere and near-planet magnetotail (h greater than 1800 km), the solar EUV flux effects are significant. The electron density decreases about an order of magnitude from high to low EUV flux, while the electron temperature at least doubles. The magnetic field also increases 2 - 3 nT. In the lower ionosphere (200 - 600 km), lower EUV fluxes are associated with slightly reduced density, and higher temperature. These results are in accord with recent entry phase observations, where the electron density measured above the ionospheric density peak is lower than that observed at solar maximum during the early Pioneer Venus mission.

Ho, C. M.

Ion measurements during Pioneer Venus reentry: Implications for solar cycle variation of ion composition and dynamics

During the final, low solar activity phase of the Pioneer Venus (PV) mission, the Orbiter Ion Mass Spectrometer (OIMS) measurements found all ion species, in the midnight-dusk sector, reduced in concentration relative to that observed at solar maximum. Molecular ion species comprised a greater part of the total ion concentration as O(+) and H(+) had the greatest depletions. The nightside ionospheric states were strikingly similar to the isolated solar maximum 'disappearing' ionospheres. Both are very dynamic states characterized by a rapidly drifting plasma and 30-100 eV superthermal O(+) ions.

Grebowsky, J. M.

Plasma waves observed at low altitudes in the tenuous Venus nightside ionosphere

The Pioneer Venus (PV) Orbiter Electric Field Detector (OEFD) measured many plasma wave bursts throughout the low altitude ionosphere during the final entry phase of the spacecraft. Apart from 100 Hz bursts observed at very low altitudes (approx. 130 km), the bursts fall into two classes. The first of these is a wideband signal that is observed in regions of low magnetic field, but average densities, in comparison to the prevailing ionospheric condition. This wideband signal is not observed in the 30 kHz channel of the OEFD, but is resricted to the 5.4 kHz channel and lower. Since these bursts are observed with roughly constant burst rate above 160 km altitude, we attribute them to ion acoustic mode waves generated by precipitating solar wind electrons. The second type of signal is restricted to 100 Hz only, and is observed in the regions of low electron beta, consistent with whistler-mode waves. These waves could be generated by lightning in the Venus atmosphere if the vertical component of the magnetic field greater than 3.6 nT. Because the ionosphere is very different during the entry phase, compared to the ionosphere as observed early in the Pioneer Venus mission, any conclusions regarding the source of the plasma waves detected during entry phase cannot be applied directly to the earlier observations.

Strangeway, R. J.

The Magnetic State of the Lower Ionosphere During Pioneer Venus Entry Phase

During the entry phase of the Pioneer Venus Orbiter, defined as that period at the end of mission in 1992 when the periapsis fell below 185 km, the magnetometer made repeated measurements throughout the post midnight ionosphere until about 0430 LT. In this region the magnetic field is generally stronger at comparable altitudes than it was earlier at times of higher solar activity. This increase combined with a decrease in electron density causes the ratio of the magnetic pressure to thermal pressure to approach unity at altitudes above 200 km, whereas it was much lower than unity at these altitudes during solar maximum. From 160-200 km the magnetic field pressure exceeds that of the ionospheric plasma quite unlike the usual conditions seen at the beginning of the mission. At lowest altitudes below 150 km, however, the field becomes weaker and hence no evidence for a planetary magnetic field is found.

Russell, C. T.

The Nightside Ionosphere of Venus Under Varying Levels of Solar EUV Flux

Solar activity varied widely over the 14 year lifetime of the Pioneer Venus Orbiter, and these variations directly affected the properties of the nightside ionosphere. At solar maximum, when solar EUV was largest, the Venus ionosphere was found to extend to highest altitudes and nightward ion transport was the main source of the nightside ionosphere. At solar minimum, nightward ion transport was reduced, and electron precipitation was thought to be the main source. In this study, we have attempted a separation of spatial variations from temporal variations by examining the altitude profiles of the magnetic field, and electron density and temperature for three different solar EUV flux ranges. In the upper ionosphere and near-planet magnetotail (h greater than 1800 km), the solar EUV effects are significant. The electron density decreases about an order of magnitude from high to low EUV flux, while the electron temperature at least doubles. The magnetic field also increases 2 - 3 nT. In the lower ionosphere (200 - 600 km), lower EUV fluxes are associated with slightly reduced density, and higher temperature. These results are in accord with recent entry phase observations, where the electron density measured above the ionospheric density peak is lower than that observed at solar maximum during the early Pioneer Venus mission.

Ho, C. M.

Ion Measurements During Pioneer Venus Reentry: Implications for Solar Cycle Variation of Ion Composition and Dynamics

During the final, low solar activity phase of the Pioneer Venus mission, the Orbiter Ion Mass Spectrometer measurements found all ion species, in the midnight-dusk sector, reduced in concentration relative to that observed at solar maximum. Molecular ion species comprised a greater part of the total ion concentration as O(+) and H(+) had the greatest depletions. The nightside ionospheric states were strikingly similar to the isolated solar maximum "disappearing" ionospheres. Both are very dynamic states characterized by a rapidly drifting plasma and 30-100 eV superthermal O(+) ions.

Grebowsky, J. M.

Plasma Waves Observed at Low Altitudes in the Tenuous Venus Nightside Ionosphere

The Pioneer Venus Orbiter Electric Field Detector (OEFD) measured many plasma wave bursts throughout the low altitude ionosphere during the final entry phase of the spacecraft. Apart from 100 Hz bursts observed at very low altitudes (approx. 130 km), the bursts fall into two classes. The first of these is a wideband signal that is observed in regions of low magnetic field, but average densities, in comparison to the prevailing ionospheric condition. This wideband signal is not observed in the 30 kHz channel of the OEFD, but is restricted to the 5.4 kHz channel and lower. Since these bursts are observed with roughly constant burst rate above 160 km altitude, we attribute them to ion acoustic mode waves generated by precipitating solar wind electrons. The second type of signal is restricted to 100 Hz only, and is observed in regions of low electron beta, consistent with whistler-mode waves. These waves could be generated by lightning in the Venus atmosphere if the vertical component of the magnetic field greater than 3.6 nT. Unfortunately, the spacecraft spin axis is mainly horizontal, and only that component of magnetic field can be measured. Alternatively, the 100 Hz bursts could be generated locally through gradient drift instabilities, provided the ambient magnetic field is horizontal. Because the ionosphere is very different during the entry phase, compared to the ionosphere as observed early in the Pioneer Venus mission, any conclusions regarding the source of the plasma waves detected during entry phase cannot be applied directly to the earlier observations.

Strangeway, R. J.

A reconsideration of the effects of terminator ionopause height on the nightward ion transport at Venus

The ionopause altitude near the terminator is a crucial parameter for studies dealing with the maintenance of the nightside ionosphere of Venus. It is generally thought that, during high solar wind dynamic pressures (P(SW)) or during solar minimum conditions, the ionopause comes down to very low altitudes so that the dayside ionosphere is not able to supply sufficient plasma to maintain the observed nightside densities. However, there are a number of workable definitions of the ionopause. Near the terminator, the altitude of the ionopause differs considerably depending upon the definition. The ionopause deduced from the radio occultation experiment as well as the pressure ionopause can be significantly lower than the density ionopause deduced from the Langmuir probe at these locations. The latter refers to the altitude where the electron density falls to 100/cu cm. Using in situ data from the Pioneer Venus Orbiter, it is shown that the density ionopause remains fairly high even for high P(SW) conditions. Simple quantitative estimates indicate that significant flow of plasma is still possible under these conditions. Thus, nightward transport of plasma during high P(SW) conditions may be more efficient than has been assumed so far. Since such conditions are more prevalent during solar cycle minimum, it is argued that transport may be relevant in the maintenance of nightside ionosphere at that time also.

Kar, J.

Ionospheric simulation compared with Dynamics Explorer observations for November 22, 1981

The present study uses an extensive DE-2 data base to both constrain inputs to a time-dependent ionospheric model (TDIM) for a simulation of the ionosphere and then check the simulated densities. The investigation was carried out for both a quiet period and a substorm period. The quiet-day study produced very good agreement between modeled and observed electron densities in the topside ionosphere with two significant exceptions: First, across the polar region the DE-2 LANG densities showed fine structure in addition to the overall regional density morphology. Second, a surprising discrepancy arose in the presunrise and midlatitude trough. The TDIM densities were an order of magnitude lower than those observed by DE-2. The substorm study showed remarkably good agreement with the observed densities.

Sojka, J. J.

Discovery concepts for Mars

Two focused Mars missions that would fit within the guidelines for the proposed Discovery line are discussed. The first mission would deal with the issue of the escape of the atmosphere (Mars') to space. A complete understanding of this topic is crucial to deciphering the evolution of the atmosphere, climate change, and volatile inventories. The second mission concerns the investigation of remanent magnetization of the crust and its relationship to the ionosphere and the atmosphere.

Luhmann, J. G.

The intrinsic magnetic field and solar-wind interaction of Mars

The Venus-like interaction between the solar wind and the atmosphere of Mars is examined. The bow shock and magnetosheath of Mars indicate the presence of an obstacle to the solar wind that is somewhat larger than the size of the planet and its observed ionosphere, and also relatively larger than the Venus obstacle under comparable conditions. The intrinsic magnetic field of Mars must be no greater than 1.5 x 10 exp 12 T/cu m, or about 0.0001 times as strong as that of the earth to produce an obstacle of such small size. At least for solar minimum conditions, like those prevailing at the time of the Viking Landers, the ionospheric plasma (thermal) pressure is insufficient to balance the incident solar-wind pressure by itself. The ion and electron temperatures in the Martian ionosphere indicate the presence of local horizontal magnetic fields and heat sources in excess of solar radiation alone.

Luhmann, J. G.

Small-scale plasma irregularities in the nightside Venus ionosphere

The individual volt-ampere curves from the Pioneer Venus Orbiter electron temperature probe showed evidence for small-scale density irregularities, or short-period plasma waves, in regions of the nightside ionosphere where the Orbiter electric field detector observed waves in its 100-Hz channel. A survey of the nightside volt-ampere curves has revealed several hundred examples of such irregularities. The I-V structures correspond to plasma density structure with spatial scale sizes in the range of about 100-2000 m, or alternatively they could be viewed as waves having frequencies extending toward 100 Hz. They are often seen as isolated events, with spatial extent along the orbit frequently less than 80 km. The density irregularities or waves occur in or near prominent gradients in the ambient plasma concentrations both at low altitudes where molecular ions are dominant and at higher altitudes in regions of reduced plasma density where O(+) is the major ion. Electric field 100-Hz bursts occur simultaneously, with the majority of the structured I-V curves providing demonstrative evidence that at least some of the E field signals are produced within the ionosphere.

Grebowsky, J. M.

Venus ionospheric tail rays - Spatial distributions and interplanetary magnetic field control

The overall properties of Venus ionospheric tail rays (such as density, spatial extent, and distribution) and their relationship to the draped magnetic field configuration behind the planet were investigated using measurements obtained by the Pioneer Venus Orbiter Langmuir probe, a magnetometer, and a plasma-wave detector. The results suggest that tail rays are a normal feature of the steady solar wind interaction with Venus and are not generally associated with a central tail plasma sheet. The statistics of the tail rays occurrence point toward the existence of a distributed terminator ionosphere source, consistent with findings of Brace et al. (1990).

Ong, M.

An equatorial temperature and wind anomaly (ETWA)

Data obtained from the WATS (Wind and Temperature Spectrometer) and LP (Langmuir Probe) experiments on board DE-2 (Dynamic Explorer) during high solar activity show evidence of anomalous latitudinal variations in the zonal winds and temperature at low latitudes. The zonal winds exhibit a broad maximum centered around the dip equator, flanked by minima on either side around 25 degrees; while the temperature exhibits a pronounced bowl-shaped minimum at the dip equator which is flanked by maxima. The two minima in the zonal winds and the corresponding maxima in the temperature are nearly collocated with the crests of the well known Equatorial Ionization Anomaly (EIA). The maximum in the zonal winds and the minimum in the gas temperature are collocated with the trough of the EIA. The differences between the maxima and minima in temperature and zonal winds, on many occasions, are observed to exceed 100 K and 100 m/s, respectively. The characteristics of this new phenomenon have eluded present day empirical models of thermospheric temperature and winds. The connection among these variables can be understood from the ion-neutral drag effect on the motions of the neutrals that in turn affect their energy balance.

Raghavarao, R.