Engineering Papers⌕ Search

Engineering topics

Boynton, W. V.

Publications and source records attributed to Boynton, W. V..

At least 73 records · Page 4

The Search for Water and Other Volatiles in Martian Surface Materials: The Thermal Evolved Gas Analyzer (TEGA)

Volatile-bearing minerals and phases (e.g., Fe-oxyhydroxides, phyllosilicates, carbonates, sulfates, palagonites, glasses) may be important components of the Martian regolith. However, essentially no information exists on the mineralogical composition of volatile-bearing phases in the regolith. The Thermal Evolved Gas Analyzer (TEGA), which was part of the Mars Polar Lander payload, was to determine the abundances of two of the most important volatile compounds (i.e., water and carbon dioxide) in the martian soil and to identify the minerals or phases that harbor these volatiles. The TEGA instrument was composed of a differential scanning calorimeter (DSC) interfaced with evolved gas analysis (EGA). The EGA consisted of a Herriott cell of a tunable-diode laser (TDL) spectrometer that determines CO2 and H2O abundances. The sample chamber was to operate at about 100 mbar (-76 torr) with a N2 carrier gas flow of 0.4 sccm. Specifications of TEGA are described in detail elsewhere in this volume.

Ming, D. W.↗

After the Mars Polar Lander: Where to Next?

The recent loss of the Mars Polar Lander (MPL) mission represents a serious setback to Mars science and exploration. Targeted to land on the Martian south polar layered deposits at 76 degrees south latitude and 195 degrees west longitude, it would have been the first mission to study the geology, atmospheric environment, and volatiles at a high-latitude landing site. Since the conception of the MPL mission, a Mars exploration strategy has emerged which focuses on Climate, Resources and Life, with the behavior and history of water as the unifying theme. A successful MPL mission would have made significant contributions towards these goals, particularly in understanding the distribution and behavior of near-surface water, and the nature and climate history of the south polar layered deposits. Unfortunately, due to concerns regarding the design of the MPL spacecraft, the rarity of direct trajectories that enable high-latitude landings, and funding, an exact reflight of MPL is not feasible within the present planning horizon. However, there remains significant interest in recapturing the scientific goals of the MPL mission. The following is a discussion of scientific and strategic issues relevant to planning the next polar lander mission, and beyond.

Paige, D. A.↗

Thermal and Evolved Gas Analyses at Reduced Pressures: A Mineral Database for the Thermal Evolved Gas Analyzer (TEGA)

Volatile-bearing minerals (e.g., Fe-oxyhydroxides, phyllosilicates, carbonates, and sulfates) may be important phases on the surface of Mars. The Thermal Evolved Gas Analyzer (TEGA), which was part of the Mars Polar Lander payload, was to detect and identify volatile-bearing phases in the Martian regolith. The TEGA instrument is composed of a differential scanning calorimetry (DSC) interfaced with an evolved gas analyzer (EGA). The EGA consists of a Herriott cell of a tunable-diode laser (TDL) spectrometer that determines CO, and H2O abundances. The sample chamber in TEGA operates at about 100 mbar (-76 torr) with a N2 carrier gas flow of 0.4 sccm. Essentially no information exists on the effects of reduced pressure on the thermal properties of volatile-bearing minerals. Here we present a database for the thermal behavior of volatile-bearing phases under reduced pressure conditions.

Lauer, H. V., Jr.↗

Differential Scanning Calorimetry and Evolved Gas Analysis at Mars Ambient Conditions Using the Thermal Evolved Gas Analyzer (TEGA)

Differential Scanning Calorimetry (DSC) combined with evolved gas analysis (EGA) is a well developed technique for the analysis of a wide variety of sample types with broad application in material and soil sciences. However, the use of the technique for samples under conditions of pressure and temperature as found on other planets is one of current C development and cutting edge research. The Thermal Evolved Gas Analyzer (MGA), which was designed, built and tested at the University of Arizona's Lunar and Planetary Lab (LPL), utilizes DSC/EGA. TEGA, which was sent to Mars on the ill-fated Mars Polar Lander, was to be the first application of DSC/EGA on the surface of Mars as well as the first direct measurement of the volatile-bearing mineralogy in martian soil.

Musselwhite, D. S.↗

Thermal and Evolved Gas Analysis of Hydromagnesite and Nesquehonite: Implications for Remote Thermal Analysis on Mars

Volatile-bearing minerals (e.g., Fe-oxyhydroxides, phyllosilicates, carbonates, and sulfates) may be important phases on the surface of Mars. In order to characterize these potential phases the Thermal Evolved-Gas Analyzer (TEGA), which was onboard the Mars Polar Lander, was to have performed differential scanning calorimetry (DSC) and evolved-gas analysis of soil samples collected from the surface. The sample chamber in TEGA operates at about 100 mbar (approximately 76 torr) with a N2, carrier gas flow of 0.4 seem. Essentially, no information exists on the effects of reduced pressure on the thermal properties of volatile-bearing minerals. In support of TEGA, we have constructed a laboratory analog for TEGA from commercial instrumentation. We connected together a commercial differential scanning calorimeter, a quadruple mass spectrometer, a vacuum pump, digital pressure gauge, electronic mass flow meter, gas "K" bottles, gas dryers, and high and low pressure regulators using a collection of shut off and needle valves. Our arrangement allows us to vary and control the pressure and carrier gas flow rate inside the calorimeter oven chamber.

Lauer, H. V., Jr.↗

Data Processing for the Near Earth Asteroid Rendezvous (NEAR), X-ray and Gamma-ray Spectrometer (XGRS) Ground System

An X-ray and Gamma-ray spectrometer (XGRS) is onboard the Near Earth Asteroid Rendezvous (NEAR) spacecraft to determine the elemental composition of the surface of the asteroid 433Eros. The Eros asteroid is highly non-spherical in physical shape and the development of data management and analysis methodologies are in several areas a divergence from traditional remotely sensed geographical information systems techniques. Field of view and asteroid surface geometry must be derived virtually and then combined with real measurements of solar, spectral and instrument calibration information to derive meaningful scientific results. Spatial resolution of planned geochemical maps will be improved from the initial conditions of low statistical significance per integration by repeated surface flyovers and regional spectral accumulation. This paper describes the results of a collaborative effort of design and development of the NEAR XGRS instrument ground system undertaken by participants at the Goddard Space Flight Center, University of Arizona, Cornell University, Applied Physics Laboratory, and Max Plank institute.

McClanahan, Timothy P.↗

Data Processing for the Near Earth Asteroid Rendezvous (NEAR), X-Ray and Gamma-Ray Spectrometer (XRS) Ground System

An X-ray and Gamma-ray spectrometer (XGRS) is onboard the Near Earth Asteroid Rendezvous (NEAR) spacecraft to determine the elemental composition of the surface of the asteroid 433Eros. The Eros asteroid is highly non-spherical in physical shape and the development of data management and analysis methodologies are in several areas a divergence from traditional remotely sensed geographical information systems techniques. Field of view and asteroid surface geometry must be derived virtually and then combined with real measurements of solar, spectral and instrument calibration information to derive meaningful scientific results. Spatial resolution of planned geochemical maps will be improved from the initial conditions of low statistical significance per integration by repeated surface flyovers and regional spectral accumulation. This paper describes the results of a collaborative effort of design and development of the NEAR XGRS instrument ground system undertaken by participants at the Goddard Space Flight Center, University of Arizona, Cornell University, Applied Physics Laboratory, and Max Plank institute.

McClanahan, Timothy P.↗

Differential Scanning Calorimetry and Evolved Gas Analysis of Hydromagnesite

Volatile-bearing minerals (e.g., Fe-oxyhydroxides, phyllosilicates, carbonates and sulfates) may be important phases on the surface of Mars. In order to characterize these phases the Thermal and Evolved Gas Analyzer (TEGA) flying on the Mars'98 lander will perform analyses on surface samples from Mars. Hydromagnesite [Mg5(CO3)4(OH)2.4H2O] is considered a good standard mineral to examine as a Mars soil analog component because it evolves both H2O and CO2 at temperatures between 0 and 600 C. Our aim here is to interpret the DSC signature of hydromagnesite under ambient pressure and 20 sccm N2 flow in the range 25 to 600 C. The DSC curve for hydromagnesite under the above conditions consists of three endothermic peaks at temperatures 296, 426, and 548 and one sharp exotherm at 511 C. X-ray analysis of the sample at different stop temperatures suggested that the exotherm corresponded with the formation of crystalline magnesite. The first endotherm was due to dehydration of hydromagnesite, and then the second one was due to the decomposition of carbonate, immediately followed by the formation of magnesite (exotherm) and its decomposition to periclase (last endotherm). Evolution of water and CO2 were consistent with the observed enthalpy changes. A library of such DSC-evolved gas curves for putative Martian minerals are currently being acquired in order to facilitate the interpretation of results obtained by a robotic lander.

Lauer, H. V., Jr.↗

Thermal and evolved gas analyzer

The Thermal and Evolved Gas Analyzer (TEGA) instrument will perform calorimetry and evolved gas analysis on soil samples collected from the Martian surface. TEGA is one of three instruments, along with a robotic arm, that form the Mars Volatile and Climate Survey (MVACS) payload. The other instruments are a stereo surface imager, built by Peter Smith of the University of Arizona and a meteorological station, built by JPL. The MVACS lander will investigate a Martian landing site at approximately 70 deg south latitude. Launch will take place from Kennedy Space Center in January, 1999. The TEGA project started in February, 1996. In the intervening 24 months, a flight instrument concept has been designed, prototyped, built as an engineering model and flight model, and tested. The instrument performs laboratory-quality differential-scanning calorimetry (DSC) over the temperature range of Mars ambient to 1400K. Low-temperature volatiles (water and carbon dioxide ices) and the carbonates will be analyzed in this temperature range. Carbonates melt and evolve carbon dioxide at temperatures above 600 C. Evolved oxygen (down to a concentration of 1 ppm) is detected, and C02 and water vapor and the isotopic variations of C02 and water vapor are detected and their concentrations measured. The isotopic composition provides important tests of the theory of solar system formation.

Williams, M. S.↗

Mars Volatiles and Climate Surveyor (MVACS) Integrated Payload for the Mars Polar Lander Mission

The Mars Volatiles and Climate Surveyor (MVACS) integrated payload for the Mars Polar Lander will be launched in January 1999, with a scheduled landing on Mars' south-polar layered deposits in December 1999. Over the course of its 90-day nominal mission during the martian southern spring and summer seasons, it will make in situ measurements that will provide new insights into the behavior and distribution of martian volatiles, MVACS consists of four major instrument systems: a surface stereo imager (SSI), which will acquire multispectral stereo images of the surface and atmosphere; a 2-m robotic arm (RA), which will dig a O.5-m deep trench and acquire surface and subsurface samples that will be imaged by a focusable robotic arm camera (RAC), which will take close-up images of surface and subsurface samples at a spatial resolution of 21 micron; a meteorology package (MET), which will make the first measurements of surface pressure, temperature, and winds in Mars' southern hemisphere and employ a tunable diode laser (TDL) spectrometer to measure the water-vapor concentration and isotopic composition of CO2 in the martian atmosphere; and a thermal and evolved gas analyzer (TEGA), which will use differential scanning calorimetry and TDL-evolved gas analysis to determine the concentrations of ices, adsorbed volatiles, and volatile-bearing minerals in surface and subsurface soil samples. The unique in situ measurements made by MVACS at its high-latitude landing site will define a number of important aspects of the physical, isotopic, and chemical nature of the martian near-surface and subsurface environment that will be valuable in better understanding Mars meteorites and returned samples, as well as in the search for martian resources that could be utilized by humans.

Paige, D. A.↗

Gamma-Ray Burst Arrival Time Localizations: Simultaneous Observations by Mars Observer, Compton Gamma Ray Observatory and Ulysses

Between 1992 October 4 and 1993 August 1, concurrent coverage by the Compton Gamma Ray Observatory (CGRO), Mars Observer (MO), and Ulysses spacecraft was obtained for 78 gamma-ray bursts (GRBs). Although most of these were below the MO and Ulysses thresholds, nine were positively detected by all three spacecraft, with data quality adequate for quantitative localization analysis. All were localized independently to approximately 2 deg accuracy by the CGRO Burst and Transient Source Experiment (BATSE). We computed arrival-time error boxes with larger dimensions ranging from a few arcminutes to the diameters of the BATSE-only boxes and with smaller dimensions in the arcminute range. Three events are of particular interest: GB 930704 (BATSE 2428) has been described as a possible repeater. The arrival-time information is consistent with that hypothesis, but only just so. The GB 930706 (2431) box, at approximately 1 min x 4 min, is the only one this small obtained since Pioneer Venus Orbiter (PVO) entered the Venusian atmosphere in 1992 October. Sensitive radio and optical observations of this location were made within 8 and 9 days of the burst, but no counterpart candidates were identified. GB 930801 (2477) is the first GRB that had its localization improved by taking into account BATSE Earth occultation.

Laros, J. G.↗

Redistribution of subsurface neutrons caused by ground ice on Mars

As part of an ongoing effort to understand data that will be returned by the Mars Observer Gamma Ray Spectrometer (MOGRS) experiment, we calculate neutron and gamma ray fluxes for simple models describing near-surface ground ice on Mars. Our goal is to determine the limits in information content of remotely sensed neutrons and gamma rays is delineating the abundance of ground ice and its distribution with depth. Such ice is expected based on simple theoretical calculations of the H2O environment of the martian surface and atmosphere. We find it produces a marked redistribution of neutrons with depth. Neutron-capture gamma ray production closely follows the flux of thermal neutrons and is likewise redistributed with depth. Calculated effects at Mars mapping orbit are sufficiently large that, if ice is present at the depths and in the quantities expected, the MOGRS should provide a robust detection of its presence. Although in the information content of gamma rays and neutrons alone is not sufficient to define the many parameters needed to specify its abundance and emplacement below the surface, their combined use might allow separation of the ice abundance from its vertical distribution within the regolith.

Feldman, W. C.↗

Trace-element composition of Chicxulub crater melt rock, K/T tektites and Yucatan basement

The Cretaceous/Tertiary (K/T) boundary Chicxulub impact is the best preserved large impact in the geologic record. The Chicxulub crater has been buried with no apparent erosion of its intracrater deposits, and its ejecta blanket is known and is well preserved at hundreds of localities globally. Although most of the molten material ejected from the crater has been largely altered, a few localities still preserve tektite glass. Availability of intra- and extracrater impact products as well as plausible matches to the targeted rocks allows the comparison of compositions of the different classes of impact products to those of the impacted lithologies. Determination of trace-element compositions of the K/T tektites, Chicxulub melt rock, and the targeted Yucatan silicate basement and carbonate/evaporite lithologies have been made using instrumental neutron activation analysis (INAA) and inductively coupled plasma mass spectrometry (ICP-MS). Some sample splits were studied with both techniques to ensure that inter-laboratory variation was not significant or could be corrected. The concentration of a few major and minor elements was also checked against microprobe results. Radiochemical neutron activation analysis (RNAA) was used to determine Ir abundances in some samples.

Hildebrand, A. R.↗