Engineering Papers⌕ Search

Engineering topics

Bowyer, S.

Publications and source records attributed to Bowyer, S..

At least 109 records · Page 6

The distribution of singly ionized ionospheric helium from 304 A backscatter observations

The theoretical distribution of helium ions in the ionosphere is studied as a function of such ionospheric parameters as the remaining ion composition and distribution, temperature, magnetic field topology, and ionospheric dynamics. An attempt is made to verify the theoretical predictions of the H(+) distribution in the ionosphere on the basis of observations of 304 A radiation resonantly scattered from He(+).

Chakrabarti, S.↗

Analysis of SETI data collected in the parasitic mode

A system for performing SETI observations continuously as part of non-SETI observations at a radio observatory is presented, and the analysis of results obtained by the parasitic system is discussed. The system, designated SERENDIP, is a real-time microprocessor-controlled spectrum analyzer with algorithms for performing statistical operations and recording those spectra with characteristics presumed to be typical of intelligent rather than astrophysical origin. Programs also exist for the post-acquisition analysis of signal autocorrelation, power spectra, time behavior and positional coordinates, and for a generalized cluster analysis to detect clusters of signal detections. In a recent run of 35 days, the SERENDIP system detected 4000 narrowband spectra exceeding a preset threshold, of which 98% were determined to be of instrumental origin. The remaining class of detections is also believed to be instrumental, although not as well organized as the first signals, and means are currently being sought for eliminating them.

Bowyer, S.↗

X-ray and optical variability in 2A1052+606 - A new RS CVn-type system

The paper discusses a star with RS CVn-type characteristics discovered as a result of an accurate X-ray location. The RS CVn binaries have been found to be a new class of soft X-ray sources from the HEAO 1 low energy sky survey. The source was detected at energies below 1 keV and evidence is presented for variability on time scales of approximately 1 day. The strong soft X-ray source was observed at a position consistent with 2A1052+606 and the X-ray light curve shows that the source underwent a strong soft X-ray flare. Subsequent spectrophotometry revealed variable H(alpha) and possibly CaII H,K emission which strongly supports its classification as an RS CVn system.

Charles, P.↗

A search for X-ray bursts from extragalactic supernovae using the HEAO 1 satellite

The soft X-ray data from the low energy detectors of the HEAO 1 A-2 experiment are surveyed in the 0.15-3.0 keV range to search for X-ray bursts (less than 1 hour) from extragalactic supernovae predicted by Klein and Chevalier. To within the operating sensitivity of 0.08 photons per sq cm/s no events were discovered from the first 8 months of operation. This is consistent with the theoretical prediction that the probability of finding one such event is small. The HEAO 2 satellite should be capable of detecting supernovae out to 2000 Mpc; these events are of cosmological interest.

Klein, R. I.↗

Interstellar absorption of the extreme ultraviolet flux from two hot white dwarfs

Photometric upper limits on the 300 A flux from the hot white dwarfs Feige 24 and G191-B2B are presented. The limits, which were obtained with a rocket-borne extreme ultraviolet imaging telescope, are interpreted as lower limits on the density of the intervening interstellar matter. The limits are used to investigate the state of interstellar gas within 100 pc. A local clumpiness factor, which is of value in planning future extreme ultraviolet observations, is derived.

Cash, W.↗

A precise position and optical identification for 4U 2129+47 - X-ray heating and a 5.2 hour binary period

A precise (20 arcsec) position and an optical counterpart are presented for the weak X-ray source 4U 2129+47. The optical counterpart shows weak but distinct He II 4686-A and C III-N III 4640-4650-A emission. Both H-beta and Ca II H and K are sometimes visible in absorption. Numerous plates and spectrophotometric observations from the 1978 observing season show that the blue magnitude varies from 16.7 to 18.0 in a period of 5.2382 hours. The light curve is sinusoidal in appearance, but with sharply defined V-shaped minima. It is proposed that most of the optical emission from this system originates at the X-ray heated face of the normal star and hence that this system is analogous to HZ Her/Her X-1. This is one of the few intrinsically faint optical counterparts of X-ray sources that show clear evidence of binary nature. The observations suggest a distance of 1.2-1.6 kpc for the source, and a consequent X-ray luminosity of approximately 10 to the 34.8 ergs/s.

Thorstensen, J.↗

2A 0526-328 - An X-ray-emitting cataclysmic variable

The weak hard X-ray source 2A 0526-328 is identified with a previously unknown cataclysmic variable on the basis of its optical emission-line spectrum and a precise X-ray location. This star has a V magnitude of about 11 and spectral properties similar to dwarf novae at minimum light and AM Her, but shows no polarization. It is likely to be a Z Camelopardalis-type system in a very extended standstill (i.e., 'novalike' or UX Ursae Majoris-type) or a recurrent nova that has not erupted in recent times.

Charles, P.↗

Discovery of X-rays from the 40 Eridani system

The detection of a point source of soft X-rays (H0405-08) consistent with the position of the nearby triple star system 40 Eridani is reported. The source, which has a temperature near 10 million K, has a flux of 3 x 10 to the -11th erg/sqcm-sec at earth, implying a luminosity of 9(+ or -3) x 10 to the 28th erg/s at the distance of 40 Eridani. The likely source of the bulk of the X-rays is considered, including the K1 dwarf, the DA white dwarf, the dwarf M4 flare star, or accretion onto the white dwarf.

Cash, W.↗

The local interstellar helium density - Corrected

An upper bound for the number density of neutral helium in the local interstellar medium of 0.004 + or - 0.0022 per cu cm was previously reported, based on extreme-ultraviolet telescope observations at 584 A made during the 1975 Apollo-Soyuz Test Project. A variety of evidence is found which indicates that the 584-A sensitivity of the instrument declined by a factor of 2 between the last laboratory calibration and the time of the measurements. The upper bound on the helium density is therefore revised to 0.0089 + or - 0.005 per cu cm.

Freeman, J.↗

Apollo-Soyuz survey of the extreme-ultraviolet/soft X-ray background

The paper reports results of the most extensive survey to date of the EUV/soft X-ray background, obtained with an EUV telescope on the Apollo-Soyuz mission. The principal results may be summarized as follows: (1) an intense background flux exists down to energies of 100 eV (4.0 plus or minus 1.3 photons/sq cm/sec/sr/eV average diffuse flux); (2) the Apollo-Soyuz data alone places lower and upper limits on single-temperature models for EUV-emitting interstellar gas for the log T range of 5.1-6.0; and (3) the allowed range would have to be restricted to log T of 5.1-5.6 for the Cash, Malina, and Stern (1976), Burstein et al. (1977), and Apollo-Soyuz data sets to satisfy a single-temperature model for the background at not greater than 280 eV.

Stern, R.↗

Observations of the cosmic background radiation at 1440 angstroms

A survey of the summer night sky in the 1350-1550-A band at 2.5-deg angular resolution was carried out with a far-ultraviolet channel of the Berkeley Extreme Ultraviolet (EUV) telescope on the Apollo-Soyuz mission. The large collecting area and small field of view of this telescope permitted the identification and removal from the data of individual stars of spectral type A2 or earlier with visual magnitude brighter than about 6.5. A residual signal significantly above background remains which is not of terrestrial or interplanetary origin and varies with view direction between approximately 30 and 2000 counts/s. The source of the emission is observed to be highly concentrated to the galactic plane with a distribution of half-width about 10 deg centered on the plane and a roughly constant-intensity tail extending out to both galactic poles. The minimum signal detected at high and moderate latitudes corresponds to 300 + or - 60 photons/sq cm-s-sr-A. This minimum flux may be due to scattering from interstellar dust, or it may be extragalactic in origin.

Paresco, F.↗

The interstellar oxygen edge in the X-ray spectrum of the Crab Nebula

Measurement of the X-ray spectrum of the Crab Nebula by the HEAO 1 A-2 low-energy (0.15-3 keV) detectors is reported. The spectral restoration techniques described by Blissett and Cruise (1979) and Kahn and Blissett (1979) are used to demonstrate explicitly the existence of a 'negative' feature near 0.5 keV that is consistent with the edge expected due to absorption by interstellar oxygen. For a simple power-law model with photon index -2.08, the data require a column density of 3.0 + or - 0.1 x 10 to the 21st per sq cm and an oxygen abundance of 1.0 + or - 0.1 times the Brown and Gould (1970) value. Satisfactory fits can also be achieved with the more sophisticated Fireman (1974) models, but no model can be adjusted to fit the data without the inclusion of interstellar oxygen.

Charles, P. A.↗

Far ultraviolet photometry of intermediate brightness stars from Apollo-Soyuz

We present photoelectric photometry in the 1350-1600 A band of 52 stars of intermediate brightness, using data obtained in 1975 July with a grazing incidence telescope aboard the Apollo-Soyuz Test Project. Upper or lower limits on the brightness of 106 additional objects which were spatially blended with one or more companions were also obtained. The data sample consists of stars with V not greater than 7.5 and spectral types from O6 through A5. When corrected for interstellar extinction, the ultraviolet photometry on a two-color diagram agrees very well with the predictions of the revised blanketed model atmospheres by Kurucz. Attention is also drawn to an anomalously UV-bright object which is probably associated with HD 100493.

Crawford, R.↗

The cosmic X-ray experiment aboard HEAO-1

The cosmic X-ray experiment aboard the HEAO-1 observatory is described, The instrument consists of six gas proportional counters of three types nominally covering the energy ranges of 0.15 keV, 1.2-20 keV, and 2.5-60 keV. The two low energy detectors have about 400 sq cm open area each while the four others have about 800 sq cm each. A novel feature of this experiment is the dual field of view collimators that allow the unambiguous determination of instrument internal background and diffuse X-ray brightness. Instrument characteristics and early performance are discussed.

Rothschild, R.↗

Continuous discharge Penning source with emission lines between 50 A and 300 A

The present paper deals with a modified Penning discharge lamp developed specially to cover the soft X-ray and extreme UV spectral regions. The source produces a total of nearly 40 intense lines in the 50 to 300 A range. The lamp is quiet, continuous, and stable over most of the cathode lifetime (which is sufficient for long calibration runs). When the cathodes become exhausted, the refurbishment procedure is so simple that the source can be back on line in an hour or less

Finley, D. S.↗

Evidence for a massive X-ray halo around Markarian 541

Mkn 541, a Type I Seyfert galaxy, has been detected as an X-ray source with the rotating modulation collimator on SAS 3. The galaxy, which is identified as the optical counterpart of 4U 2351+06, has an X-ray flux of 3 x 10 to the -11th erg/sq cm per sec, which corresponds to a luminosity of 2 x 10 to the 44th erg/s at 240 Mpc. Evidence is presented that the X-rays are emitted in a volume of diameter 150 kpc. A variety of possible emission mechanisms are investigated, and it is suggested that the X-rays are caused by thermal bremsstrahlung from 500 billion solar masses of hot gas trapped in the gravitational well of Mkn 541, which implies that the mass of the galaxy exceeds 5 trillion solar masses. The hot gas can be explained as the accumulated ejecta of the Seyfert nucleus.

Cash, W.↗

First spectrum of an extra-solar object in the extreme ultraviolet The white dwarf HZ 43

An EUV instrument is described which has been used to carry out a spectroscopic observation of the hot white dwarf HZ 43. The instrument consists of an EUV telescope and spectrometer housed in a sounding-rocket shell 44 cm in diameter and 176 cm in length. It is noted that HZ 43 was successfully observed for 200 sec and that the EUV spectrum was strongly detected from 170 to 400 A. A second-order image was detected beyond 400 A, and a decrement was observed at 200 A, which corresponds to photoelectric absorption of He II. The observed spectrum is shown to be inconsistent with a coronal model. It is concluded that the surface number density of helium relative to hydrogen must be in the range from 0.00001 to 0.0001 and that an upper limit of 4 x 10 to the 17th per sq cm can be placed on the column density of ionized helium in the intervening interstellar medium.

Malina, R. F.↗

Wolter-Schwarzschild optics for the extreme-ultraviolet - The Berkeley stellar spectrometer and the EUV Explorer

The design, fabrication and performance of two Wolter-Schwarzschild grazing incidence optics are described. Both telescopes have been figured by single point diamond turning and have achieved better than 15-arcsec on-axis imaging. The telescope for the stellar spectrometer is an f/10 Type II system with an effective area of 225 sq cm at 250 A and 300 cm2 at 500 A. The primary has a maximum diameter of 38 cm and was fabricated in three elements. The copper-plated aluminum substrate was diamond turned; following nickel plating, the surface was polished and coated with evaporated gold. The performance during a sounding rocket flight is discussed. The prototype telescope for the Extreme Ultraviolet Explorer is an f/1.24 Type I system with an effective field of view of 5.0-deg diameter. The telescope has a maximum diameter of 40 cm and was fabricated as a single element. The aluminum substrate is to be diamond turned; the nickel plated surface will be polished and electroplated with gold. The design choice and defocusing optimization aimed at maximizing the field of view and number of image pixels is examined.

Malina, R. F.↗